EEWORLDEEWORLDEEWORLD

Part Number

Search

56.710.0055.0

Description
Modular Terminal Block, 125A, 10mm2
CategoryThe connector    terminals   
File Size313KB,2 Pages
ManufacturerWieland Electric GmbH
Websitehttps://www.wieland-electric.com/
Download Datasheet Parametric View All

56.710.0055.0 Overview

Modular Terminal Block, 125A, 10mm2

56.710.0055.0 Parametric

Parameter NameAttribute value
MakerWieland Electric GmbH
Reach Compliance Codecompliant
ECCN codeEAR99
Is SamacsysN
Fastening methodSPRING LOADED
Manufacturer's serial numberWKFN
Installation typeDIN RAIL
Rated current125 A
Rated voltage500 V
Terminal and terminal strip typesMODULAR TERMINAL BLOCK
Conductor cross section10 mm2
Base Number Matches1
fasis
fasis
Description
The
fasis
WKFN
terminals can be used in a single-
tier design with 2, 3 and 4 clamping points per
potential or double-deck terminals in two and three
tier designs for switching tasks where installation
space is restricted, also available with diode circuits
if required. Potential can be distributed quickly and
flexibly using the jumper bars. Further modificati-
ons can be easily implented.
All variants are available as through terminals and
earth terminals while the double-deck terminals are
available for a variety of potentials combinations.
DIN Rail Terminals with
Spring Clamp Connection, TypeWKFN
CUSTOMER INFORMATION
Technical data according to EN 60947-7:
Rated cross section:
1.5 mm
2
– 35 mm
2
Rated current:
17 A – 125 A
.5
Rated voltage:
800 / 500 V
Wire range:
0.08 – 35mm
2
mark
Clearly mark all clamping positions
Benefits:
• Clear view of marking tag, even after termination.
• Error free identification improves installation.
• Simplified fault location when carrying out maintenance
tasks.
• Customised labelling with the marking system
wiemarc.
clamp
Flexible and universal connections
Benefits:
• Terminal compartment in accordance with gauge plug
EN 60947-7
.
• Connection of solid, stranded and finely stranded conductors
for example WKFN 4: 0.13 up to 6 mm
2
• Connection of finely stranded conductors with insulated
ferrules from 0.5 mm
2
up to the rated cross-section.
jump
Facilitate jumpering with dual row cross
connections
Benefits:
• Flexibility in the equipotential distribution with staggered and
daisy chain arrangement of the jumper bars.
• Reduced costs from use of standardised products.
• Distribution of primary power supply up to 76 A using standard
jumper bars and modular terminals.
test
Measuring the voltage via the integrated test
points
Benefits:
• Testing even when fully wired (including jumper bars).
• Test point directly on the current carrying bar.
• Functional test with modular test adapter using the test
sensor in the bridging channel.
Display bmp picture below EVC
RT which big brother has the reference code, send it to me, the points are not much, I will definitely give...
dfx168 Embedded System
Can anyone recommend a DC-DC converter that can boost voltage to 5V using two batteries?
[color=#000000]Recently, I am working on a remote control device and a smart switch for smart home. The wireless module uses an ordinary superheterodyne transmitter module, and the remote control uses...
analog010 Power technology
Has anyone used Winbond's 78E516B to make a serial port transceiver? Please help.
I am now using Philips' p89c669 to communicate with Winbond's w78e56b. The function implemented is: p89c669 sends a string of 24-byte commands, and w78e516b returns a command to p89c669 after receivin...
pilot Embedded System
How to use stm32 nucleo l053
How to use stm32 nucleo l053...
左左凯 stm32/stm8
TI SimpleLink is going live! It will start on September 8th~ Pre-register to watch and win gifts!
September 8 (Friday) 10:00 AM Live: Tell you about a magical wireless MCU platform TI SimpleLink, Bluetooth, WiFi, 6LoWPAN, ZigBee... common protocols are all available! Wireless development artifact[...
EEWORLD社区 TI Technology Forum
PWM input capture, problem of selecting trigger source
I use CH1, CH2 and CH3 of TIM2 as input pins respectively. The trigger source selections for CH1 and CH2 are TIM_TS_TI1FP1 and TIM_TS_TI2FP2 respectively. But when using CH3, why is there no TIM_TS_TI...
引线太短啦 stm32/stm8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2886  190  1874  370  2750  59  4  38  8  56 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号