Part Number

Search

326438DP115

Description
Power/Signal Relay, 4PDT, Momentary, 10A (Contact), 28VDC (Contact), AC/DC Output, Panel Mount
CategoryMechanical and electronic products    relay   
File Size359KB,4 Pages
ManufacturerSTPI Siege Social
Download Datasheet Parametric View All

326438DP115 Overview

Power/Signal Relay, 4PDT, Momentary, 10A (Contact), 28VDC (Contact), AC/DC Output, Panel Mount

326438DP115 Parametric

Parameter NameAttribute value
Objectid1052529878
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresCOIL OPERATE VOLTAGE(AC): 100 V; COIL RELEASE VOLTAGE(AC): 5 V
body width26 mm
body height25.7 mm
Body length or diameter26 mm
Maximum coil voltage (AC)115 V
Contact (AC) maximum rated R load10A@115VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)10 A
Contact (DC) maximum rated R load10A@28VDC
Maximum contact voltage (AC)115 V
Maximum contact voltage (DC)28 V
Contact/Output Power TypeAC/DC
Electrical life100000 Cycle(s)
JESD-609 codee4
Manufacturer's serial number326
Installation featuresPANEL MOUNT
operating hours16 ms
Maximum operating temperature125 °C
Minimum operating temperature-65 °C
physical size26mm X 26mm X 25.7mm
Relay actionMOMENTARY
Relay function4PDT
Relay typePOWER/SIGNAL RELAY
release time51 ms
sealHERMETICALLY SEALED
surface mountNO
Terminal surfaceGOLD
Termination typeSOLDER HOOK
326 4
RT -
4
PDT
/10
A
327 4
RT -
4
PDT
/15
A
RELAIS HERMETIQUES
MONOSTABLES
HERMETICALLY SEALED
NON LATCHING
RELAY
CARACTERISTIQUES GENERALES
326
Combinaison des contacts
Contact arrangement
GENERAL CHARACTERICS
327
4 RT
4 PDT
4 RT
4 PDT
Pouvoir de coupure 28 Vcc - 1 5 V/400 Hz
1
Contact rating 28 Vdc - 115 V/400 Hz
Circuit résistif
Resistive load
10 A
10 Amps
1 A
5
15 Amps
Circuit inductif (L/R = 5 ms)
Inductive load (L/R = 5 ms)
8A
8 Amps
10 A
10 Amps
Circuit moteur
Motor load
4A
4 Amps
6A
6 Amps
Circuit lampe
Lamp load
2A
2 Amps
3A
3 Amps
Alimentation
Supply
Courant continu (polarisé) ou courant alternatif 50/400Hz ou 50/60Hz ou 400Hz
Direct current (polarized) or alternative current 50 /400 Hz or 50/60 Hz or 400 Hz
Masse
Weight
70 g à 76 g max.
70 g to 76 g max.
Normes applicables en annexe
See appendice for applicable specifications
ENVIRONNEMENT
Température de fonctionnement
Temperature range
ENVIRONMENT
- 65° à + 1
25°C
- 65° to + 125°C
Position de fonctionnement
Operating position
Indifférente
Any
Tenue aux vibrations
Resistance against vibrations
Sinus : 30 g - 10 - 3 000 Hz / Aléatoire : 0,4 g
2
/Hz - 50 - 2 000 Hz
Sinus : 30 g - 10 - 3 000 Hz / Random : 0,4 g
2
/Hz - 50 - 2 000 Hz
Tenue aux chocs
Shocks resistance
200 g - 6 ms / 100 g - 1 ms
1
200 g - 6 ms / 100 g - 11 ms
Tenue aux secousses
Shake resistance
40 g
40 g
Accélération
Acceleration
20 g
20 g
Taux de fuite
Leak rate
< 1.10
-8
cm
3
/sec
< 1.10
-8
cm
3
/sec
58 Av. Claude VELLEFAUX - 75010 PARIS - FRANCE
326 1/4
51
Tel : 33.(0)1.42.03.94.20 - Fax : 33.(0)1.42.03.52.85 - www.stpigroup.com
EVM: Error vector magnitude vector magnitude error
EVM: Error vector magnitudevector errorEVM is one of the most important indicators in the field of digital communication. It is affected by the following 7 aspects.1. IQ branch gain imbalance. Assume ...
btty038 RF/Wirelessly
ST17 Motor Training Materials
The attachment is the ST-17 motor training material. The 4.3 library used at that time is now available in ST 5.0. I will update it later. :loveliness:...
newdrive Motor Drive Control(Motor Control)
Cui Yongyuan went to the United States to investigate GMOs
Don't just read the title, read the whole article [url=http://scitech.people.com.cn/n/2013/1112/c1007-23518890.html]http://scitech.people.com.cn/n/2013/1112/c1007-23518890.html[/url] [b]From doubt to ...
wangfuchong Talking
Seeking advice on solenoid valve
Dear friends, has anyone done a solenoid valve project? How did you achieve it? Please give me some advice....
丙寅电子 Analog electronics
How does an application call a shell command?
[color=#000][font=arial][size=14px]I want to make a shell command parser for vxworks. How does the shell respond to i? Which library and function is called? If I call it directly, what header files do...
小黑卜哭 Embedded System
Is this the correct definition of industrial control?
Industrial control refers to industrial control computers, which are a general term for tools that use a bus structure to detect and control the production process and its electromechanical equipment ...
totopper Industrial Control Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2242  973  788  2612  2667  46  20  16  53  54 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号