1 POLE(S), 0.5A, 250 V(AC), 50 V(DC), PANEL MOUNT, THERMAL CIRCUIT BREAKER,
CategoryCircuit protection    Circuit protection   
File Size441KB,5 Pages
ManufacturerE-T-A [E-T-A Circuit Breakers]
Download Datasheet Parametric View All

3120-F553-H7T1-W02A-0.5A Overview

1 POLE(S), 0.5A, 250 V(AC), 50 V(DC), PANEL MOUNT, THERMAL CIRCUIT BREAKER,

3120-F553-H7T1-W02A-0.5A Parametric

Parameter NameAttribute value
Objectid1145922637
Reach Compliance Codecompliant
Actuator typeROCKER
circuit functionMANUAL ON/OFF
Circuit protection typeTHERMAL CIRCUIT BREAKER
Installation featuresPANEL MOUNT
Number of poles1
Maximum operating temperature60 °C
Minimum operating temperature-30 °C
Rated breaking capacity5 A
Rated current0.5 A
Rated voltage (AC)250 V
Rated voltage (DC)50 V
GuidelineCCC; CSA; UL; VDE
surface mountNO
Terminal shapeQUICK CONNECT
Thermal Overcurrent Circuit Breaker 3120-F...
Description
An extremely versatile range of rocker switch/thermal circuit breakers
(S-type TO CBE to EN 60934 with trip free mechanism) offering the choice
of single pole, double pole with single pole protection, and double pole
with protection on both poles. Designed for snap-in panel mounting with
versions available for three different panel cut-out sizes. Illumination is
optional and there is a range of colours and markings for the rocker.
Add on modules:
Under voltage release coil (for double pole versions only).
Magnetic trip coil for short circuit protection.
Magnetic trip coil for remote relay trip.
Auxiliary contacts for status signalling.
Approved to CBE standard EN 60934 (IEC 60934).
Meets the requirements regarding fire resistance of EN 60335-1 : 2007-02
Safety of household and similar electrical appliances.
3120-F3...F5
Typical applications
Technical data
Motors, transformers, solenoids, extra low voltage wiring systems, office
machines, electro-medical equipment, power supplies, communications
systems, medical equipment to EN 60601.
Standard current ratings and typical internal resistance values
Current rating
(A)
0.1
0.2
0.3
0.4
0.5
0.6
0.8
1
1.2
1.5
2
2.5
3
3.5
Internal
resistance
per pole (Ω)
94
24
12
5.30
4.20
2.90
1.50
0.9
0.80
0.45
0.27
0.0785
0.0595
0.0565
Current rating
(A)
4
4.5
5
6
7
8
10
12
14
15
16
18
20
Internal
resistance
per pole (Ω)
0.0435
0.0435
0.0325
0.0215
0.0165
0.0165
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
Dielectric strength
(IEC 60664 and 60664A)
operating area
between poles (2-pole)
Insulation resistance
Interrupting capacity I
cn
3120-F7
2
For further details please see chapter: Technical Information
Voltage rating
AC 240 V; DC 50 V
(AC 415 V to special order)
(UL: AC 250 V; DC 50 V)
Current ratings
0.1...20 A
(up to 30 A to special order, single pole only)
Typical life
AC 240 V:
DC 50 V:
DC 28 V:
AC 415 V:
AC 240 V:
0.1...20 A
0.1...4 A
4.5...16 A
0.1...20 A
0.1...16 A
0.1...16 A
17...20 A
DC 50 V:
0.1...16 A
17...20 A
Ambient temperature
Insulation co-ordination
(IEC 60664 and 60664 A
1-pole
30,000 operations at 1 x I
N
, inductive
30,000 operations at 1 x I
N
, inductive
30,000 operations at 1 x I
N
, resistive
30,000 operations at 1 x I
N
, inductive
2-pole
10,000 operations at 1 x I
N
, inductive
50,000 operations at 1 x I
N
, inductive
30,000 operations at 1 x I
N
, inductive
50,000 operations at 1 x I
N
, inductive
10,000 operations at 1 x I
N
, inductive
-30...+60 °C (-22...+140 °F)
rated impulse
pollution
withstand voltage
degree
2.5 kV
2
reinforced insulation in operating area
Illumination voltage/power consumption
operating voltage
12 V DC
24 V DC
115 V AC
230 V AC
power consumption
Y+R
2 mA
2 mA
0.9 mA
0.9 mA
G
3.5 mA
3.5 mA
2.8 mA
2.8 mA
test voltage
AC 3,000 V
AC 1,500 V
> 100 MΩ (DC 500 V)
0.1...2 A 10 x I
N
2.5...20 A 250 A 2-pole, or 150 A 1-pole
Interrupting capacity (UL 1077)
I
N
1, 2-pole
1, 2-pole
Degree of protection
(IEC 60529/DIN 40050)
Vibration
0.1...20 A
0.1...20 A
U
N
AC 250 V
DC 50 V
I
nc
5000 A
1000 A
Approvals
Authority
VDE (EN 60934)
Voltage ratings
AC 240 V; DC 28 V
DC 50 V
DC 50 V
AC 250 V; DC 50 V
AC 250 V; DC 50 V
Current ratings
0.1...20 A
0.1...20 A
2-pole
0.1...10 A
1-pole
0.1...20 A
0.1...20 A
Shock
Corrosion
Humidity
Mass
UL, CSA
CCC
operating area IP40
(IP54 with water splash protection)
terminal area IP00
8 g (57-500 Hz), ± 0.61 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
30 g (11 ms)
to IEC 60068-2-27, test Ea
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH,
to IEC 60068-2-78, test Cab
approx. 33 g (double pole)
approx. 27 g (single pole)
Issue D
www.e-t-a.de
2
- 67
Let me share my thoughts on the forum (if I post to the wrong section, please forgive me)
I haven't been to the forum for a long time. I was too busy recently. I went online today and found that it is still very popular. It's really good. Although many forums and QQ groups have many people...
五月一 FPGA/CPLD
Guitar electronics development direction research field
Dear IT experts and colleagues, do you like guitars? I would like to know about the development prospects of electronics related to guitars, such as guitar pickups, etc. Thank you!...
ky0611 TI Technology Forum
MSP430 LaunchPad Timer Interrupt (Continuous Mode)
#include msp430g2231.hint main( void ) { // Stop watchdog timer to prevent time out reset WDTCTL = WDTPW + WDTHOLD;P1DIR |= 0x01;TACCTL0 = CCIE; // Enable the interrupt generated by the CCIFG flagTACC...
Jacktang Microcontroller MCU
【NXP IoT Module Review】Unpacking
[i=s] This post was last edited by ljj3166 on 2018-7-2 23:48 Edit[/i] [align=left][font=宋体]It's been a while since I got the platform[/font][/align][align=left][font=宋体]Recently I've been busy with th...
ljj3166 NXP MCU
Requesting VxWorks network driver development information
Requesting VxWorks network driver development information...
huadong_l58 PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1726  113  514  2501  1731  35  3  11  51  31 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号