EEWORLDEEWORLDEEWORLD

Part Number

Search

NT73-2CS5DC48V0.45

Description
Small size, light weight, heavy reverse power. / Low coil power consumption.
File Size267KB,2 Pages
ManufacturerDBLECTRO
Websitehttp://www.dblectro.com
Download Datasheet View All

NT73-2CS5DC48V0.45 Overview

Small size, light weight, heavy reverse power. / Low coil power consumption.

NT73-2CS5DC48V0.45 Preview

Features
Small size, light weight, heavy reverse power.
Low coil power consumption.
PC board mounting.
Suitable for automation control, telecommunication equipment, household electrical appliance and machinery electrical
facilities.
Ordering Information
NT73-2
1
C S 10
2
3
4
DC12V 0.36
5
6
4 Contact rating:5A,10A,12A,15A/125VAC 28VDC;6A/277VAC
20A/125VAC 16VDC10A/250VAC(0.8W)
ü
V
:
6A/250VAC 28VDC
;T
5 Coil rated Voltage(V):DC:3,5,6,9,12,24,48
6 Coil power consumption:0.36:0.36W;0.45:0.45W;0.8:0.8W
1 Part number:NT73-2
2 Contact arrangement:A:1A;B:1B;C:1C
3 Enclosure:S: Sealed type;NIL: Dust cover
Contact Data
Contact Arrangement
Contact Material
Contact Rating (resistive)
1A SPSTNO
f1B
SPSTNC
f1C
SPDT(B-M)
Ag CdO
Ag SnO
2
5A,6A,10A,12A,15A/125VAC,28VDC;20A/125VAC,16VDC;
6A/277VAC;10A/250VAC
T
ü
V
:
6A/250VAC, 28VDC (15A 0.4W ; 20A 0.8W coil only )
Motor load: 1/3HP 125VAC ; 1/3HP 277VAC
420W 2500VA
110VDC 380VAC
Max. Switching Current:20A
100m
Item 3.12 of IEC255-7
5
10
Item 3.30 of IEC255-7
7
10
Item 3.31 of IEC255-7
Max. Switching Power
Max. Switching Voltage
Contact Resistance or Voltage drop
Operation
Electrical
life
Mechanical
Coil Parameter
Pickup
release voltage Coil power
Operate
Release
voltage
Coil resistance
Dash
VDC(min)
consumpti
VDC(max)
Time
Time
±10%
numbers
(10% of rated
on
(75%of rated
ms
ms
voltage)
W
Rated
Max.
voltage )
003-360
3
3.9
25
2.25
0.3
005-360
5
6.5
70
3.75
0.5
006-360
6
7.8
100
4.50
0.6
10
5
009-360
9
11.7
225
6.75
0.9
0.36
012-360
12
15.6
400
9.00
1.2
024-360
24
31.2
1600
18.0
2.4
048-360
48
62.4
6400
36.0
4.8
003-450
3
3.9
20
2.25
0.3
005-450
5
6.5
55.6
3.75
0.5
006-450
6
7.8
80
4.50
0.6
10
5
009-450
9
11.7
180
6.75
0.9
0.45
012-450
12
15.6
320
9.00
1.2
024-450
24
31.2
1280
18.0
2.4
048-450
48
62.4
5120
36.0
4.8
003-800
3
3.9
11
2.25
0.3
005-800
5
6.5
31
3.75
0.5
006-800
6
7.8
45
4.50
0.6
10
5
009-800
9
11.7
101
6.75
0.9
0.80
012-800
12
15.6
180
9.00
1.2
024-800
24
31.2
720
18.0
2.4
048-800
48
62.4
2880
36.0
4.8
CAUTION
:
1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
Coil voltage
VDC
81
Solderability
Ambient Temperature
Relative Humidity
Mass
235’x2’ 3x0.5s
-55~85’
93% (at 40’)
9.5g
IEC68-2-20 Test Ta method 1
IEC68-2-3Test Ca
Qualification inspection:
Perform the qualification test as specified in the table
of IEC255-19-1 and minimum sample size 24.
Safety approvals
Safety approval
UL
20A/125VAC 16VDC
10A/250VAC 6A/277VAC
1/3HP 125VAC/277VAC
Insulation B-class F-class
T
ü
V
6A/250VAC 28VDC
CCEE
Load
7A/250VAC
Dimensions
(Unit: mm)
mm
0.3
0.4
0.5
1.0
1.3
1.4
1.0
3.9
6
12
12.2
15.3
16.5
19.5
>àçÇá
Dimensions
Mounting (Bottom views)
Wiring diagram(Bottom views)
NOTES
1).Dimensions are in millimeter.
2).Inch equivalents are given for general information only.
0.012
0.016
0.020
0.039
0.051
0.055
0.079
0.153
0.236
0.472
0.480
0.602
0.650
0.768
Reference Data
Classification of high-power IGBT drive protection circuits
According to the functions that the high-power IGBT driver protection circuit can complete, the high-power IGBT driver protection circuit can be divided into the following three types: single-function...
TLP781 Power technology
How to change the horizontal axis of the wince touch screen driver to reverse the horizontal axis?
: I am using a 480*800 screen. Now I want to change the position of the (0,0) point of the touch screen to (800,0). The ordinate remains unchanged, but the abscissa is reversed. Please tell me how to ...
binghai1029 Embedded System
Arbotix Usage Process
Implementation process:Installing ArbotixCreate a new function package and prepare robot urdf and xacro filesAdd Arbotix ProfileWrite a launch file to configure ArbotixStart the launch file and contro...
warmcrack2020 Robotics Development
Blood pressure parameters_Testing methods for monitoring parameters of monitoring products (Part 3)
6. Inspection and evaluation methods of non-invasive blood pressure measurement characteristics 1. Overview The non-invasive blood pressure measurement function is one of the most basic monitoring par...
冰人 Medical Electronics
TI ultrasonic testing equipment system block diagram and composition
Hehe, share it....
soso Mobile and portable
Graduation project for digital frequency meter
I'm looking for a graduation project on a digital frequency meter. I'd be very grateful. Thank you:)...
xuqingxuan MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2906  872  2597  2638  1749  59  18  53  54  36 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号