EEWORLDEEWORLDEEWORLD

Part Number

Search

1.000MHZHC49/50/20/30/50PF/SLF

Description
Parallel - Fundamental Quartz Crystal, 1MHz Nom, RESISTANCE WELDED, HERMATIC SEALED PACKAGE-2
CategoryPassive components    Crystal/resonator   
File Size156KB,1 Pages
ManufacturerEuroquartz
Websitehttp://www.euroquartz.co.uk/
Environmental Compliance
Download Datasheet Parametric View All

1.000MHZHC49/50/20/30/50PF/SLF Overview

Parallel - Fundamental Quartz Crystal, 1MHz Nom, RESISTANCE WELDED, HERMATIC SEALED PACKAGE-2

1.000MHZHC49/50/20/30/50PF/SLF Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
package instructionRESISTANCE WELDED, HERMATIC SEALED PACKAGE-2
Reach Compliance Codecompliant
Is SamacsysN
Ageing3 PPM/FIRST YEAR
Crystal/Resonator TypePARALLEL - FUNDAMENTAL
Drive level1000 µW
frequency stability0.002%
frequency tolerance50 ppm
load capacitance50 pF
Installation featuresTHROUGH HOLE MOUNT
Nominal operating frequency1 MHz
Maximum operating temperature80 °C
Minimum operating temperature-30 °C
physical sizeL11.5XB4.9XH13.6 (mm)/L0.453XB0.193XH0.535 (inch)
Series resistance5000 Ω
surface mountNO
Base Number Matches1
THROUGH-HOLE CRYSTALS
HC49 SERIES CRYSTALS
DESCRIPTION
HC49 crystals are a long-established industry-standard part. Basic
specification HC49 crystals provide the lowest cost crystal available but
these crystals can also be manufactured to very close tolerances and low
ESR values. Holder variants are HC49/T (truncated), providing a lower
height version, 3-wire versions where the crystal base and body can be
earthed by a centre earth wire and HC50 which has larger diameter leads
specifically for socket mounting.
OUTLINES & DIMENSIONS
FEATURES
·
·
·
·
·
·
Very low cost crystal
Available with close tolerances
Fully customisable specification
Comprehensive Euroquartz stockholding
Industry-standard package with options
Very wide frequency range
GENERAL SPECIFICATION
Frequency Range:
Calibration Tolerance at 25ºC:
Frequency stability over temp:
Load Capacitance:
Ageing:
Drive level:
Static capacitance (C0):
Holder:
Part Numbers for Holder Variants *
Holder Type
Standard 2 lead:
Low height versions:
Centre Earth Lead:
Centre Earth Lead (Low):
‘Plug-in’ for use in socket:
Holder Designation
HC49
HC49/T (from 4.0MHz)
HC49/3W
HC49/T/3W (from 4.0MHz)
HC-50
1.0MHz to 250.0MHz
from ±3ppm to ±50ppm
from ±3ppm to ±100ppm
8pF to 50pF, or Series
±3ppm max 1st year,
±1ppm max per year after
1mW max
7pF max
Resistance-weld, hermetic seal
* HC49 crystals are also available for surface-mount applications with
formed leads and fitted with a clip. See ‘49MJ’ in the surface-mount
crystal section on Euroquartz website; www.euroquartz.co.uk
OSCILLATION MODE & ESR
Frequency
(MHz)
1.0 ~ 1.3
2.01 ~ 3.0
3.01 ~ 3.2
3.21 ~ 3.5
3.51 ~ 3.9
3.91 ~ 5.0
5.01 ~ 7.0
7.01 ~ 10.0
10.0 ~ 30.0
30.1 ~ 45
24.0 ~ 100
80.0 ~ 160
110 ~ 250
Crystal Cut/
Oscillation Mode
SL Fund.
AT Fund.
AT Fund.
AT Fund.
AT Fund
AT Fund.
AT Fund.
AT Fund.
AT Fund.
AT Fund.
AT 3
rd
OT
AT 5th OT
AT 7th OT
ESR (max)
(Ohms)
5000
400
200
150
120
100
50
35
25
20
40
70
120
FREQUENCY STABILITY OVER TEMPERATURE
Operating
Temp. °C
0° to +50°
-10° to +60°
-20° to +70°
-30° to +80°
-40° to +90°
-55° to +105°
Temperature Stability (ppm)
±3
ü
ü
X
X
X
X
±5
ü
ü
ü
X
X
X
±7.5
ü
ü
ü
X
X
X
±10
ü
ü
ü
ü
X
X
±15
ü
ü
ü
ü
ü
X
±20
ü
ü
ü
ü
ü
ü
±30
ü
ü
ü
ü
ü
ü
PART NUMBER GENERATION
HC49 crystal part numbers are derived as follows:
ü
Indicates this stability is available over the stated operating temp. range
Example:
16.000MHz HC49/30/50/10/30pF/ATF
Frequency/Holder/Calibration/Temp. Stability/ Temp. Range/Circuit
EUROQUARTZ LIMITED Blacknell Lane CREWKERNE Somerset UK TA18 7HE
Tel: +44 1460 230000 Fax: +44 1460 230001 email: info@euroquartz.co.uk web: www.euroquartz.co.uk
Could you please help me, it's not difficult for you.
1. The mileage pulse signal is input from external 0 (INT0). For each pulse signal, the system adds 0.1km and records the mileage. 2. The interrupt method of timer Tx is used to achieve 10s timing (bu...
919202089 51mcu
Ask a question about calling the library function of the CAN module
Have you ever used the CAN module of the TM4C series microcontroller? When entering an interrupt, you need to read the CANINT register, right? It is used to determine the current interrupt source. How...
shiqiaocanxue Microcontroller MCU
LSM330DLC sensor reading problem
[table=98%,rgb(238, 238, 238)] [tr][td]As the title says, I want to tinker with ST's sensor [b]LSM330DLC[/b] recently. I used the development board kit before. ST has software for the Windows platform...
Farid stm32/stm8
Moderator, now I have encountered a tricky problem, about stopping and waking up.
I want to implement interrupts and events on one interrupt line at the same time. Is it possible?Why do I want to do this? The reason is that I want the interrupt of the external interrupt line EXTI5 ...
天天流浪 stm32/stm8
In this way, how to query the value of the special function register in AXD? Do we need to transfer it through variables in the program?
In this way, how to query the value of the special function register in AXD? Do we need to transfer it through variables in the program?...
nibuhao123 Embedded System
The role of the diode at the input point of the comparator LM393
As shown in the figure, what is the role of diodes D1 and D2? Thank you!...
xiaxingxing Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2680  1382  1198  2854  1507  54  28  25  58  31 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号