1200BGH1009F2RB

Description
Strain Guage Sensor, Gage, 0Psi Min, 1000Psi Max, 0.5%, 4-20mA, Cylindrical
CategoryThe sensor    Sensor/transducer   
File Size507KB,4 Pages
ManufacturerGems Sensors & Controls
Download Datasheet Parametric View All

1200BGH1009F2RB Overview

Strain Guage Sensor, Gage, 0Psi Min, 1000Psi Max, 0.5%, 4-20mA, Cylindrical

1200BGH1009F2RB Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
Reach Compliance Codeunknown
Maximum accuracy(%)0.5%
shellSTAINLESS STEEL
Nominal offset4MA
Maximum operating temperature50 °C
Minimum operating temperature-20 °C
Output range4-20mA
Output typeANALOG CURRENT
Package Shape/FormCYLINDRICAL
port typeG1/8 FEMALE
Maximum pressure range1000 Psi
Minimum pressure range
Pressure sensing modeGAGE
Sensor/Transducer TypePRESSURE SENSOR,STRAIN GUAGE
Maximum supply voltage35 V
Minimum supply voltage7 V
Termination typeCABLE
Base Number Matches1
The national competition is coming soon. Here is a bonus: National Undergraduate Electronic Design Competition Training Course - Basic Skills Training and Unit
[i=s]This post was last edited by paulhyde on 2014-9-15 02:55[/i] National Undergraduate Electronic Design Competition Training Course - Basic Skills Training and Unit...
白丁 Electronics Design Contest
Why should we use Coway PLC chipset to develop customized PLC? (1)
The so-called customized PLC refers to the PLC created by yourself. Just think about it, would it be a great sense of accomplishment to build a PLC by yourself? But if you want to make a PLC real-time...
断琴残风 MCU
Russian training!
The Russians’ strength is not just bragging, it is also the result of real training!...
spj2007 Talking
PLC Programming (Beginners)
PLC Programming (Beginners) contributed to everyone!...
eeleader Industrial Control Electronics
When I send AT commands to the GPRS module using the HyperTerminal, there is a response (the response is also correct), but when I use a general serial port debugging tool, there is no response, only the corresponding AT command is displayed. Why?
When I send AT commands to the GPRS module using the HyperTerminal, there is a response (the response is also correct), but when I use a general serial port debugging tool, there is no response, only ...
wanghai8521 Embedded System
Issues that need attention in Verilog's signed and unsigned operations
The simplest addition, subtraction, multiplication and division operations in Verilog are actually very different for signed and unsigned numbers. Here are a few points to summarize:Example: Take the ...
eeleader FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1305  1394  1544  2811  517  27  29  32  57  11 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号