Results in economical use of duct space and facilitates
installation
Two jacket layers and two steel tape armor layers
Provide superior rodent resistance for direct-buried ap-
plications
Innovative waterblocking technology
Eliminates the need for traditional flooding compound
and provides efficient and craft-friendly cable preparation
Medium-density polyethylene jacket
Rugged, durable and easy to strip (while providing supe-
rior protection against UV radiation, fungus, abrasion and
other environmental factors)
Corning ALTOS
®
RD double-jacket, single-armored ca-
bles are rugged armored cables with a reduced diameter
designed for direct-buried, duct and aerial (lashed) in-
stallation. The loose tube design provides stable perfor-
mance over a wide temperature range and is compatible
with any telecommunications-grade optical fiber.
Standards
Design and Test Criteria
ANSI/ICEA S-87-640
Telcordia GR-20
RDUP PE-90
ALTOS RD Double-Jacket, Single-Armored Cables,
300 Fibers
| Photo PIM1403
Family Spec Sheet 0037_NAFTA_AEN
Page 1 | Revision date 2014-08-08
ALTOS RD Double-Jacket, Single-Armored Cables,
432 Fibers
| Photo PIM1413
ALTOS
®
RD Cables Double-Jacket, Single-
Armored, 300-432 Fibers
Polyethylene (PE)
Outer Jacket
Polyethylene (PE)
Inner Jacket
Water-Swellable
Tape
Ripcord
Water-Swellable
Tape
Buffer
Tube
Fiber
Dielectric Central
Element
Filling Element
Water-Swellable
Tape
Water-Swellable
Tape
Corrugated Steel
Armor
Polyethylene (PE)
Outer Jacket
Polyethylene (PE)
Inner Jacket
Ripcord
Water-Swellable
Tape
Dielectric Central
Element
Fiber
Buffer
Tube
Water-Swellable
Tape
Water-Swellable
Tape
Water-Swellable
Tape
Corrugated Steel
Armor
ALTOS RD Double-Jacket, Single-Armored Cables,
300 Fibers
| Photo PIM2301
ALTOS RD Double-Jacket, Single-Armored Cables,
432 Fibers
| Photo PIM2311
Specifications
Temperature Range
Storage
Installation
Operation
-40 °C to 70 °C (-40 °F to 158 °F)
-30 °C to 70 °C (-22 °F to 158 °F)
-40 °C to 70 °C (-40 °F to 158 °F)
*
Note: Corning recommends storing cable in a proper temperature environment prior to installation to allow the cable temperature to meet installation tempera-
ture range specifications for best installation results.
Max. Tensile Strength, Short-Term
Max. Tensile Strength, Long-Term
2700 N (600 lbf)
890 N (200 lbf)
Mechanical Characteristics Cable
Fiber Count Product
Type
300 - 432
Armored
Maximum
Fibers per
Tube
12
Number of
Tube Posi-
tions
36
Number
of Active
Tubes
25 - 36
Weight
Nominal
Outer Dia-
meter
25.5 mm
(1.01 in)
Min. Bend
Radius
Installation
386 mm
(152 in)
Min. Bend
Radius
Operation
257 mm
(101 in)
520 kg/km
(352 lb/1000 ft)
*
Tubes 13 to 24 include a co-extruded stripe that is white for the black tube and black for all other tube colors.
*
Tubes 25 to 36 include a co-extruded stripe that is white for the red tube and red for all other tube colors.
Family Spec Sheet 0037_NAFTA_AEN
Page 2 | Revision date 2014-08-08
ALTOS
®
RD Cables Double-Jacket, Single-
Armored, 300-432 Fibers
Chemical Characteristics
RoHS
Free of hazardous substances according to RoHS 2002/95/
EG
Transmission Performance
Multimode
Fiber Core Diameter
(
µm
)
Fiber Category
Fiber Code
Performance Option Code
Wavelengths
(
nm
)
Maximum Attenuation
(
dB/km
)
Serial 1 Gigabit Ethernet
(
m
)
Serial 10 Gigabit Ethernet
(
m
)
Min. Overfilled Launch (OFL)
Bandwidth
(
MHz*km
)
Minimum Effective Modal
Bandwidth (EMB)
(
MHz*km
)
62.5
OM1
K
30
850/1300
3.4/1.0
300/550
33/-
200/500
220/-
50
OM2
T
31
850/1300
3.0/1.0
750/500
150/-
700/500
950/-
50
OM3
T
80
850/1300
3.0/1.0
1000/600
300/-
1500/500
2000/-
50
OM4
T
90
850/1300
3.0/1.0
1100/600
550/-
3500/500
4700/-
*
Single-mode (OS2) fiber is ITU-T G.652.D compliant.
Notes:
1)
Improved attenuation and bandwidth options available.
2)
Bend-insensitive single-mode fibers available on request.
3)
50 µm multimode fiber macrobend loss ≤ 0.2 dB at 850 nm for two turns around 7.5 mm radius mandrel.
4)
Contact a Corning Customer Care Representative for additional information.
Single-mode
Fiber Name
Fiber Category
Fiber Code
Performance Option Code
Wavelengths
(
nm
)
Maximum Attenuation
(
dB/km
)
Typical Attenuation*
(
dB/km
)
SMF-28e+
®
fiber
G.652.D
E
01
1310/1383/1550
0.4/0.4/0.3
0.33/0.33/0.19
SMF-28e+
®
fiber
G.652.D
E
00
1310/1383/1550
0.35/0.35/0.25
0.33/0.33/0.19
Family Spec Sheet 0037_NAFTA_AEN
Page 3 | Revision date 2014-08-08
ALTOS
®
RD Cables Double-Jacket, Single-
Armored, 300-432 Fibers
Ordering Information |
Note: Contact Customer Care at 1-800-743-2675 for other options.
1
Select fiber count.
Standard offerings:
300-432
Increments of 12
4
Defines outer jacket.
5 = Double-jacket, single-
armored
8
Select performance
option code.
30 = 62.5 µm multimode (OM1)
31 = 50 µm multimode (OM2)
80 = 50 µm multimode (OM3)
90 = 50 µm multimode (OM4)
01 = Single-mode (OS2)
(Max. attenuation 0.4/0.4/0.3 dB/km)
2
Select fiber code.
K = 62.5 µm multimode
(OM1)
T = 50 µm multimode,
(OM2/OM3/OM4)
E = Single-mode (OS2)
SMF-28e+
®
fiber
5
Defines fiber placement.
T = 12 fibers/buffer tube
(standard)
00 = Single-mode (OS2)
6
Select length markings.
3 = Markings in meters
4 = Markings in feet
(standard)
(Max. attenuation 0.35/0.35/0.25 dB/km)
9
Defines cable type.
N = ALTOS RD Cable
3
Defines cable type.
W = ALTOS
®
RD Cable
7
Defines tensile strength.
1 = 2700 N/600 lbf (standard)
10
Defines special
manufacturing code.
20 = No special requirements
Corning Optical Communications LLC • PO Box 489 • Hickory, NC 28603-0489 USA
Wireless communication integration mainly refers to radio communication, not communication tools such as mobile phones!The main direction is that the walkie-talkie can realize a mode similar to that o...
I plan to implant an operating system for an arm m3-based MCU. I saw OSE Epsilon RTOS, an operating system designed specifically for m3, but I couldn't find the source code or information. Does anyone...
Why can't the dat file generated by converting the bmp image through matlab be displayed after loading into CCS? . . . I'm a novice.My matlab code is:x=imread(\'D:\\Matlab6.5\\11.bmp\');y=double(x);fi...
1. When the car is in reverse gear, the distance and alarm are immediately displayed on the LCD screen. 2. When the distance is greater than 2m, it displays "safe" and the measured distance, and conti...
Motion detection recording is one of the important functions of network cameras. The sensitivity of motion detection can be adjusted, and the recording can be sent to the email address specified by th...
Current Development Status of DVR Market
A DVR, or digital video recorder, uses a hard disk for recording, unlike traditional analog video recorders. It's often called a DVR because it's a com...[Details]
In mobile technology, sensors are the primary input for measured signals and form a component of a sensor system. They include sensitive and transducer elements connected to carriers and circuits. ...[Details]
Capable of providing precise and efficient thermal management for artificial intelligence computing power, intelligent sensing and autonomous driving systems
Shenzhen, ...[Details]
Electric vehicles are now widespread, but they've brought with them a host of problems, the most prominent of which is charging. Small electric vehicles (EVs) are a new form of transportation in a ...[Details]
Keysight Technologies is combining its electromagnetic simulator with Synopsys' AI-driven RF design migration flow to create an integrated design flow for migrating from TSMC's N6RF+ process techno...[Details]
Plessey Semiconductors has been acquired by Haylo Labs, which was established in March last year with a $100 million, five-year loan from Chinese technology company Goertek.
Haylo Labs w...[Details]
Linear motor modules have become the "sweet spot" in various fields due to their advantages such as long stroke, fast speed, high precision, smooth operation and long life. Different models of line...[Details]
A patent disclosed by Ford proposes replacing traditional segmented side curtain airbags with integrated full-width side curtain airbags that span the side of the vehicle and can be deployed simult...[Details]
In the field of intelligent driving, regulations are becoming increasingly stringent, and the technical threshold continues to rise. Especially after the traffic accident in March 2025, the Ministr...[Details]
In daily life, when we purchase a transformer, we are faced with the installation and wiring procedures. Generally speaking, large transformers such as power transformers are equipped with speciali...[Details]
Introduction: In digital circuit calculations, there is no concept of decimal points. You know where the decimal is, but the circuit does not know where the decimal point is. Therefore, you need to...[Details]
The mobile computing market is rapidly evolving, and manufacturers are fiercely competing for market share. A key area of competition is battery life, which encompasses two key aspects: how long th...[Details]
In camera and display systems, the demand for high-performance and low-power data interfaces is driving continuous technological evolution. The evolution of MIPI D-PHY and MIPI C-PHY clearly ...[Details]
0 Introduction
With a rapidly aging population, a young couple is now required to care for an increasing number of elderly people, leading to a growing difficulty in providing care for them. E...[Details]
We know that the power output by the engine does not directly act on the wheels to drive the car, but needs to pass through a series of power transmission mechanisms. So how is the power transmitte...[Details]