NHG RELAYS
N375
73.7 54.1 35.6
C
US
E160644
Features
heavy reverse power 30A/300VAC 28VDC
Optional mounting ways.
Firm structure, strong anti-shock & anti vibration.
Suitable for automatic control, household electrical appliances and machinery electrical facilities.
Ordering Information
N375 3C a DC12V P
1
2
3
4
5
4 Coil rated voltage DC:6,12,24,48,110
AC: 6,12,24,48,120,208,240
5 Cover F:F mode; P:P mode; TM:TM model
1 Part number N375
2 Contact arrangement 3A:3A 3B:3B 3C:3C
3 Terminal a: inserting type b: PCB type
Contact Data
Contact Arrangement
Contact Material
Contact Rating
(Resistive)
Max. Switching Power
Max. Switching Voltage
Max. Resistance or
Voltage drop
Operation
al Electrical
life
Mechanical
3A (3PSTNO)
3B (3PSTNC) 3C (3PDT (B-M))
AgCdO AgSnO
2
3A,3B,3C:30A/300VAC,28VDC; 2HP 240VAC , 1HP 120VAC
900W 9000VA
150VDC 380VAC
50m
1 10
5
1 10
7
Max. Switching Current:30A
Item 3.12 of IEC255-7
Item 3.30 of IEC255-7
Item 3.31 of IEC255-7
Coil Parameter
Dash
numbers
Rated
voltage
V
Rated
AC
006AC
012AC
024AC
048AC
120AC
208AC
240AC
6
12
24
48
120
208
240
DC
Max.
Coil
resistance
10%
Pick up
voltage
V(max)
85%of rated
voltage
5.1
10.2
20.4
40.8
102.0
176.8
204.0
75%o
f
Release
voltage
V(min)
20%of rated
voltage
1.2
2.4
4.8
9.6
24.0
41.6
48.0
10%o
f
COIL
POWER
Operate
Time
ms
Release
Time
ms
6.6
13.2
26.4
52.8
132
229
264
2.4
9.5
35
150
570
3075
3800
4.5VA
rated voltage
rated voltage
006-2600
012-2600
024-2600
048-2600
110-2600
6
12
24
48
110
6.6
13.2
26.4
52.8
121
14
55
230
900
4900
4.5
9.0
18.0
36.0
82.5
0.6
1.2
2.4
4.8
11.0
2.6W
15
5
CAUTION:
1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.