EEWORLDEEWORLDEEWORLD

Part Number

Search

DA225-B-B-B

Description
Toggle Switch, SPST, On-off, Latched, Wire Terminal, Bat Type Actuator, Panel Mount-threaded
CategoryMechanical and electronic products    switch   
File Size105KB,1 Pages
ManufacturerCarling Technologies
Environmental Compliance
Download Datasheet Parametric View All

DA225-B-B-B Overview

Toggle Switch, SPST, On-off, Latched, Wire Terminal, Bat Type Actuator, Panel Mount-threaded

DA225-B-B-B Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Reach Compliance Codecompli
ECCN codeEAR99
Actuator colorBLACK
Actuator length0.687 inch
Actuator typeBAT TYPE
body width14.93 mm
body height17.44 mm
Body length or diameter25.4 mm
Nozzle length0.28 inch
Contact (AC) maximum rated power R load1.5HP@250VAC
Contact (AC) maximum rated R load20A@125VAC
Maximum contact current (AC)20 A
Contact functionON-OFF
Maximum contact voltage (AC)125 V
Dielectric withstand voltage1000V V
Electrical life50000 Cycle(s)
Insulation resistance100000000 Ω
insulator materialNYLON
Manufacturer's serial numberD
Installation featuresPANEL MOUNT-THREADED
Maximum operating temperature85 °C
Minimum operating temperature
surface mountNO
Switch actionLATCHED
switch functionSPST
Switch typeTOGGLE SWITCH
Termination typeWIRE
Base Number Matches1
Carling
Technologies
D-Series Single Pole Toggle Switches
D-Series Single Pole Toggle Switches
The D-Series single pole compact high current toggle
switches are ideal for applications with back panel size
constraints. These switches feature self-cleaning contacts
and ratings up to 20A 125VAC, 10A 250VAC, 1 1/2 HP
125-250VAC. With an economical double insulated all-
nylon construction, these switches figure prominently in
the Environmental Controls, Marine, Food Service,
Vacuum Cleaner and various other general purpose mar-
kets with stringent current carrying requirements.
.156[3.96] DIA
Dielectric Strength
UL/CSA:
1000V - live to dead
metal parts & opposite polarity
TUV: 4000V - live to dead metal
parts; 750V - across open
contacts
Electrical Life
50,000 cycles
Mechanical Life
100,000 cycles
Operating Temperature
32°F to 185°F (0°C to 85°C)
.069[1.75] DIA
6.000[152.4]
.375[9.52]
.500[12.70]
INTEGRATED WIRE LEAD
(no exposed conductors)
.250[6.35]
SOLDER LUG
.687[17.44]
KEYWAY
.072[1.82]
X
.038[.965] DP
.250[6.35]
.250 TAB (Q.C.)
TERMINAL TYPE
.280[7.11]
.687[17.44]
.500[12.70] DIA
.062[1.57]
.500[12.70] DIA
.376[9.55]
.375[9.52]
.038[9.65]
1.000[25.40]
.588[14.93]
MOUNTING HOLE
WITH KEYWAY
.500[12.70] DIA
.125[3.17] DIA
WITH LOCKING RING
DA221
-
P
-
B
-
B
1
Base Part Number
2
Actuator
Style
3
Actuator
Color
4
Bushing
Color
1 BASE PART NUMBER: SERIES/CIRCUITRY/RATING/TERMINATION
10A 250VAC, 20A 125VAC, 1 1/2 HP 125-250VAC
solder
.250
wire
lug
tab
leads
OFF-NONE-ON
DA220
DA221
DA225
ON-NONE-ON
DB220
DB221
DB225
ON-OFF-ON
DC220
DC221
DC225
5A 250VAC, 10A 125VAC, 1/2 HP 125-250VAC,
4(4) 250VACµ TUV approved
wire
leads
DA945
1
2 ACTUATOR STYLE
B
bat
3 ACTUATOR COLOR
2
B
black
4 BUSHING COLOR
2
B
black
P
paddle
W
white
W
white
ON-NONE-OFF
NOTES
1
2
Available with wire leads and ON-OFF circuit only.
Additional colors available. Please consult factory.
www.carlingtech.com
29
What are the UL2056 test report sample test requirements for mobile power supplies exported to Japan or sold on Amazon?
[align=left] UL2056 is a safety standard for mobile power terminal products launched by the United States. UL 2056 responds to the global demand for safety standards for mobile power, protects consume...
张工13902399542 Energy Infrastructure?
Help, about 430 P1 interrupt
I refer to the launchpad pocket experiment platform guide. But I use the last 4 bits of P1 to interrupt and P6 to connect to the LED display, but it doesn't work. It's not an entry level, please corre...
REMY Microcontroller MCU
[Repost] Understand the key points of power DDR hardware design in one article
[align=left][font=微软雅黑]Key points of DDR hardware design[/font][/align][align=left][font=微软雅黑]1. Power supply DDR power supply can be divided into three categories: [/font][/align][align=left][font=微软...
皇华Ameya360 Power technology
I am frustrated. My desktop computer is connected to the wireless network, but I cannot open the web page.
I am so depressed. My desktop computer is connected to the wireless network, but I can't open the web page. My mobile phone can access the Internet normally....
gurou1 Talking
About the problem of capturing the falling edge of the serial port by simulating the IO port of 430 and 449
Hello everyone, I would like to ask a question. I use the 2.0 and 2.1 ports of 430f449 to simulate the serial port, 2.0 for output, 2.1 for input. Turn on the SEL of 2.1, and then use TIMERB0 to captu...
lopwind Microcontroller MCU
HDMI decoding chip problem
I would like to ask about the HDMI decoding chip. An E2PROM is connected to the I2C interface of HDMI, and the I2C is connected to the decoding chip. Without this E2PROM, the decoding chip cannot reco...
fengqufengsui TI Technology Forum

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1958  2910  1629  497  1726  40  59  33  10  35 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号