EEWORLDEEWORLDEEWORLD

Part Number

Search

BK/C515-2.5-R

Description
Electric Fuse, Time Delay Blow, 2.5A, 250VAC, 100A (IR), Through Hole, ROHS COMPLIANT
CategoryCircuit protection    Circuit protection   
File Size246KB,2 Pages
ManufacturerCooper Industries
Environmental Compliance
Download Datasheet Parametric View All

BK/C515-2.5-R Overview

Electric Fuse, Time Delay Blow, 2.5A, 250VAC, 100A (IR), Through Hole, ROHS COMPLIANT

BK/C515-2.5-R Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerCooper Industries
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
Is SamacsysN
Fusing characteristicsTIME DELAY
body height15.2 mm
Body length or diameter5.5 mm
Circuit protection typeELECTRIC FUSE
JESD-609 codee3
Joule integral nominal78 J
Manufacturer's serial numberC515
Installation featuresTHROUGH HOLE
method of packingBOX
physical size5.5mm x 15.2mm
Rated breaking capacity100 A
Rated current2.5 A
Rated voltage (AC)250 V
GuidelineCSA; UL
surface mountNO
Terminal surfaceTin (Sn)
Terminal shapePIN WIRE
Base Number Matches1
5 x 15mm Axial-Leaded, Time-Delay, Glass Tube Fuses
C515 Series
Dimensions
- mm
Drawing Not to Scale
Description
• Axial-leaded, time-delay
• 5 x 15mm physical size
• Nickel-plated brass endcap construction
• Leads are tin coated
• Optional sleeve is flexible flouropolymer
(UL Flammability rating VW-1).
• UL Listed product meets standard UL 248-14
Agency Information
• UL Listed Card: C515 125mA-250mA and 375mA-3A
(Guide JDYX, File E19180)
• UL Recognized Card: C515 350mA, and 3.5A-7A
(Guide JDYX2, File E19180)
• CSA Certification Card: C515 125mA-250mA and
375mA-3A (Class 1422-01, 53787
Ordering
Specify product code
• Insert packaging code prefix before part number.
E.g., BK (or TR2)/C515-2-R
• With TR2 packaging code, lead wire length is 20.3mm
Specify option code, if desired
• For insulation sleeve, insert “S” after part series.
E.g., BK/C515S-2-R
Voltage
Rating
Vac
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
125
125
125
125
125
Electrical Characteristics
Amp Rating
Opening Time
135%
60 minutes max.
125mA - 250mA
3 seconds min.
200%
120 seconds max.
100%
4 hours min.
470mA
30 minutes max.
350mA
600mA
90 seconds max.
2A
2 seconds max.
6A
500 milliseconds max.
135%
60 minutes max.
375mA - 7A
3 seconds min.
200%
120 seconds max.
Rated Current
Specifications
Product Code
C515-125-R
C515-250-R
C515-350-R
C515-375-R
C515-500-R
C515-600-R
C515-750-R
C515-800-R
C515-1-R
C515-1.25-R
C515-1.5-R
C515-1.6-R
C515-2-R
C515-2.25-R
C515-2.5-R
C515-3-R
C515-3.5-R
C515-4-R
C515-5-R
C515-6-R
C515-7-R
Interrupting
Rating (amps)
600Vac
250Vac
125Vac
-
35
10000
-
35
10000
25
35
10000
-
35
10000
-
35
10000
-
35
10000
-
35
10000
-
35
10000
-
35
10000
-
100
10000
-
100
10000
-
100
10000
-
100
10000
-
100
10000
-
100
10000
-
100
10000
-
-
400
-
-
400
-
-
400
-
-
400
-
-
400
Typical DC Cold
Resistance*
Ω
(Ω)
4.72
1.32
1.04
0.81
0.54
0.38
0.26
0.23
0.14
0.13
0.100
0.090
0.059
0.057
0.046
0.035
0.028
0.023
0.019
0.014
0.013
Typical
Melting I
2
t**
0.101
0.467
1.169
1.531
2.280
6.982
9.162
10.544
14.289
22.961
31.989
35.156
60.256
97.724
78.163
80.426
149.279
233.346
354.813
471.360
710.500
Max
Voltage
Drop (mV)***
770
430
530
470
440
350
310
260
230
220
240
200
170
180
190
150
130
130
150
125
100
*DC Cold Resistance (Measured at <10% of rated current)
**Typical Melting I
2
t (A
2
Sec) (Minimum I
2
t at 10 times rated current)
***Typical Voltage Drop (Voltage drop was measured at 25°C ambient temperature at rated current)
1009
BU-SB09716
Page 1 of 2
Data Sheet 2006
Application of input surge current suppression module in AC-DC converter
Application of input surge current suppression module in AC/DC converter Abstract: This paper analyzes the surge current impact and harm of capacitor input filter rectifier on power supply when it is ...
zbz0529 Analog electronics
Article sharing: Capacitance-to-digital converters facilitate level detection in diagnostic systems
In blood analyzers, in vitro diagnostic systems, and many other chemical analysis applications, liquids must be transferred from one container to another in order to draw samples from test tubes or re...
雨中 ADI Reference Circuit
Blue_char Demo(ios)
[i=s] This post was last edited by elike on 2018-1-21 17:38 [/i] [size=4]1. Tool preparation [/size] [size=3] [font=微软雅黑] Low-power Bluetooth development kit [/font] STEVAL-IDB007V1. As shown in the f...
elike ST - Low Power RF
2010 Shandong Province College Student Electronic Design Competition Outstanding Paper
[i=s] This post was last edited by paulhyde on 2014-9-15 09:25 [/i] 2010 Shandong Province Undergraduate Electronic Design Competition Outstanding Paper...
bingyan1122 Electronics Design Contest
Please advise on the Emulator issue in WinCE6.0 development (how to make your own SDK, Emulator)
I have just come into contact with WinCE. What I need to do is to develop applications on general WinCE devices. I plan to export a general WinCE6.0 SDK on PB6.0 and install it myself, then write code...
浪儿飘 Embedded System
Vxworks network programming questions
I implemented Ethernet communication under Vxworks, using UDP protocol. In debugging state, the program runs normally. Pinging the target machine and testing the program with the ping command are both...
zds1982 Real-time operating system RTOS

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2131  2138  2504  2403  532  43  44  51  49  11 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号