BK8/ABC-8-RB

Description
Electric Fuse, Fast Blow, 8A, 250VAC, 125VDC, 200A (IR), Inline/holder, ROHS COMPLIANT
CategoryCircuit protection    Circuit protection   
File Size253KB,2 Pages
ManufacturerCooper Industries
Environmental Compliance  
Download Datasheet Parametric View All

BK8/ABC-8-RB Overview

Electric Fuse, Fast Blow, 8A, 250VAC, 125VDC, 200A (IR), Inline/holder, ROHS COMPLIANT

BK8/ABC-8-RB Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerCooper Industries
package instructionROHS COMPLIANT
Reach Compliance Codeunknown
Is SamacsysN
Other featuresRATED BREAKING CAPACITY AT 125 VDC: 10000 A
Fusing characteristicsFAST
body height31.75 mm
Body length or diameter6.35 mm
Circuit protection typeELECTRIC FUSE
Joule integral nominal116 J
Manufacturer's serial numberABC
Installation featuresINLINE/HOLDER
method of packingBOX
physical size6.35mm x 31.75mm
Rated breaking capacity200 A
Rated current8 A
Rated voltage (AC)250 V
Rated voltage (DC)125 V
GuidelineCSA; UL
surface mountNO
Terminal surfaceNickel (Ni)
Terminal shapeEND CAP
Base Number Matches1
1
4
˝ x 1
1
4
˝ Ceramic Tube Fuses
ABC Series Fast-Acting
Description
• Fast-acting
• Optional axial leads available
1
4
˝ x 1
1
4
˝ (6.4 x 31.7mm) physical size
• Ceramic tube, nickel-plated brass endcap construction
• UL Listed product meets standard 248-14
Electrical Characteristics
% of Amp Rating
Opening Time
100%
4 Hours Minimum
135%
60 Minutes maximum
200%
120 Seconds Maximum
Agency Information
• UL Listed: Guide JDYX & File E19180.
• UL Recognition: Guide JDYX2 & File E19180.
• CSA Certification: Class 1422-01 & 1422-03, File
53787.
Environmental Data
• Shock:
1
4
-30A – MIL-STD-202,
Method 213, Test Condition J
• Vibration:
1
4
-30A – MIL-STD-202,
Method 204, Test Condition C (Except 5g, 500HZ)
Ordering
• Specify packaging, product, and option code
Dimensions - mm (in)
Drawing Not to Scale
38.10
(1.500)
(REF)
32.82±0.79
(1.292±0.031)
38.10
(1.500)
(REF)
6.76
(0.266)
DIA. OF LEADS
0-15 Amp: 0.81 (REF)
(0.032)
18-30 Amp: 1.02 (REF)
(0.040)
31.75±0.79
(1.250±0.031)
6.48
(0.255)
6.35±0.1
(0.250±0.0)
Specifications
Part
Number
ABC-
1
/
4
-R
ABC-
1
/
2
-R
ABC-
3
/
4
-R
ABC-1-R
ABC-1-
1
/
2
-R
ABC-2-R
ABC-2-
1
/
2
-R
ABC-3-R
ABC-4-R
ABC-5-R
ABC-6-R
ABC-7-R
ABC-8-R
ABC-10-R
ABC-12-R
ABC-15-R
ABC-18-R
ABC-20-R
ABC-25-R
ABC-30-R
Voltage
Ratings
Vac
Vdc
250
125
250
125
250
125
250
125
250
125
250
125
250
125
250
125
250
125
250
125
250
125
250
125
250
125
250
125
250
125
250
125
250
125
250
125
125
125
125
125
Vac Interrupting
Ratings* (amps)
250
125
35
10,000
35
10,000
35
10,000
35
10,000
100
10,000
100
10,000
100
10,000
100
10,000
200
10,000
200
10,000
200
10,000
200
10,000
200
10,000
200
10,000
750
10,000
750
10,000
400
1000
400
1000
-
1000
-
1000
Vdc Interrupting
Ratings (amps)
125
75
10,000
-
10,000
-
10,000
-
10,000
-
10,000
-
10,000
-
10,000
-
10,000
-
10,000
-
10,000
-
10,000
-
10,000
-
10,000
-
10,000
-
10,000
-
10,000
-
10,000
-
10,000
-
400
1000
400
1000
Typical DC Cold
Ω
Resistance (Ω)**
2.950
0.587
0.300
0.1950
0.131
0.0890
0.061
0.047
0.031
0.026
0.021
0.016
0.014
0.011
0.0068
0.00553
0.00465
0.00366
0.0028
0.002225
Typical
Pre-Arc I
2
t AC†
0.0020
0.0390
0.1450
0.4310
1.1630
2.1670
4.4670
6.55
22.28
32.83
58
109.33
116.5
208.8
133.3
200.2
400
550.8
839.3
1429
Typical
Voltage
Drop (mV)‡
0.35
0.41
0.32
0.3
0.28
0.31
0.23
0.14
0.17
0.22
0.19
0.17
0.19
0.15
0.1
0.1
0.1
0.1
0.09
0.09
Agency Approvals
UL
UR CSA
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
* Interrupting ratings measured at 70% - 80% power factor on AC. The interrupting ratings for 20A were measured at 85% - 95% power factor on AC.
** Typical DC cold resistance measured at <10% of rated current.
† Typical melting I
2
t measured at listed interrupting rating and rated voltage.
‡ Typical voltage drop measured at 25°C±3°C ambient temperature at rated current.
0709
BU-SB09291
Page 1 of 2
Data Sheet 2000
There is no "Control Panel" icon under "Device Manager" in CE?
There is no "Control Panel" icon under "Device Manager" of CE. You need to select Control Panel through "Start->Settings". What is the reason? Where do I need to set it?...
whereis Embedded System
Help, sduc841 uses 74HC244 to expand the IO port. How to read the data?
I am using aduc841 microcontroller, which is based on 51 core. In order to expand the IO port, I connected a 74HC244 to the P0 port, and then connected a dip switch. The two enable terminals of 74HC24...
zhoulm Embedded System
PID speed control, the relationship between PID output Uk and duty cycle?
[i=s]This post was last edited by shrxh on 2018-3-26 10:34[/i] [size=14px]Expected function of the program: Control the motor speed by PWM waveform and adjust the speed by PID. [/size][size=14px]Targe...
shrxh stm32/stm8
Can I use IAR to burn the program into the MSP430F5529 development board? How to do it?
RT for detailed explanation...
daiweiqiang Microcontroller MCU
[RVB2601 Creative Application Development] Handheld Game Console (2) Drawing with Eyes
[i=s]This post was last edited by nemon on 2022-6-5 12:16[/i]Let me first talk about the game I want to make. In the distant last century, the earliest electronic game was PinPong, followed by the era...
nemon XuanTie RISC-V Activity Zone
MAX32630FTHR--UART with Bluetooth Low Energy and GPS
[i=s]This post was last edited by df_flying on 2017-9-26 23:32[/i] [size=4]MAX32630FTR actually has a BLE module. Unfortunately, this module needs to communicate with the MCU through the HCI layer to ...
df_flying DIY/Open Source Hardware

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2292  2355  2279  2811  311  47  48  46  57  7 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号