Description
Electric Fuse, Fast Blow, 30A, 250VAC, 125VDC, 200A (IR), Inline/holder,
CategoryCircuit protection    Circuit protection   
File Size217KB,2 Pages
ManufacturerEaton
Environmental Compliance  
Download Datasheet Parametric View All

BK/ABC-V-30-R Overview

Electric Fuse, Fast Blow, 30A, 250VAC, 125VDC, 200A (IR), Inline/holder,

BK/ABC-V-30-R Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerEaton
Reach Compliance Codecompliant
ECCN codeEAR99
Factory Lead Time10 weeks
Is SamacsysN
Other featuresINTERRUPTING CURRENT-MAX(DC): 1000 A , PRE ARCING TIME: OPEN WITHIN 120 SEC AT 200% RATED CURRENT
Fusing characteristicsFAST
body height31.75 mm
Body length or diameter6.35 mm
Circuit protection typeELECTRIC FUSE
Joule integral nominal1429 J
Installation featuresINLINE/HOLDER
method of packingBOX
physical size6.35mm x 31.75mm
Rated breaking capacity200 A
Rated current30 A
Rated voltage250 V
Rated voltage (AC)250 V
Rated voltage (DC)125 V
GuidelineCSA; UR
surface mountNO
Terminal surfaceNickel (Ni)
Terminal shapeEND CAP
Disconnect time or delay14400 s
Base Number Matches1
Technical Data
2000
Effective
May
2017
Supersedes
June
2013
ABC
1⁄4” x 1 1⁄4” Fast-acting ceramic tube fuses
Product features
Fast-acting, ceramic tube
Optional axial leads available
1⁄4” x 1 1⁄4” (6.4 x 31.7mm) physical size
Ceramic tube, nickel-plated brass endcap construction
UL Listed product meets standard 248-14
Agency information
UL Listed Guide JDYX & File E19180
UL Recognition Guide JDYX2 & File E19180
CSA Certification: Class No: 1422-01 &
1422-30, File 53787
ELECTRICAL CHARACTERISTICS
% of Amp Rating
Opening Time
100%
135%
200%
4 Hours Minimum
60 Minutes maximum
120 Seconds Maximum
Ordering
Specify packaging, product and option
code
* Interrupting ratings measured at 70% - 80% power factor on AC. The interrupting ratings for 18A and 20A were measured at 85% - 95% power factor on AC. The
interrupting ratings for 25A and 30A were measured at 89% power factor on AC.
** Typical DC cold resistance measured at <10% of rated current.
† Typical melting I2t measured at listed interrupting rating and rated voltage.
‡ Typical voltage drop measured at 25°C±3°C ambient temperature at rated current.
‡‡ CSA approvals for 25A and 30A are at 125Vac - IR 1000A and 125Vdc - IR 400A (IR 1000A at 75Vdc)
Part
Number
ABC-
1
4
-R
ABC-
1
2
-R
ABC-
3
4
-R
ABC-1-R
ABC-1-
1
2
-R
ABC-2-R
ABC-2-
1
2
-R
ABC-3-R
ABC-4-R
ABC-5-R
ABC-6-R
ABC-7-R
ABC-8-R
ABC-10-R
ABC-12-R
ABC-15-R
ABC-18-R
ABC-20-R
ABC-25-R
ABC-30-R
Voltage
Ratings
Vac
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
Vdc
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
Vac Interrupting
Ratings* (amps)
250V
125V
35
10,000
35
10,000
35
10,000
35
10,000
100
10,000
100
10,000
100
10,000
100
10,000
200
10,000
200
10,000
200
10,000
200
10,000
200
10,000
200
10,000
750
10,000
750
10,000
400
1000
400
1000
200
1000
200
1000
Vdc Interrupting
Ratings (amps)
125V
75V
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
400
1000
400
1000
Specifications
Typical
DC Cold
Resistance (Ω)**
2.950
0.587
0.300
0.1950
0.131
0.0890
0.061
0.047
0.031
0.026
0.021
0.016
0.014
0.011
0.0068
0.00553
0.00465
0.00366
0.0028
0.002225
Typical
Pre-Arc
I
2
t AC
0.0020
0.0390
0.1450
0.4310
1.1630
2.1670
4.4670
6.55
22.28
32.83
58
109.33
116.5
208.8
133.3
200.2
400
550.8
839.3
1429
Typical
Voltage
Drop (V)
0.35
0.41
0.32
0.3
0.28
0.31
0.23
0.14
0.17
0.22
0.19
0.17
0.19
0.15
0.1
0.1
0.1
0.1
0.09
0.09
Agency Approvals
UL UR CSA
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
‡‡
X X
‡‡
Urgent! Platform Builder cannot link to the library!
I use a chip that requires a specific algorithm, so I must use its own library. Now I can confirm that the library is for the wince5.0 platform and is a static library. That is, I have .lib, .pdb, and...
lpzgbd Embedded System
How to use malloc under ADS
The processor is pxa270 nor flash 64M sdram 64M. How to use malloc to apply for memory under ADS (totally used as a microcontroller, not running an operating system) Do I need to implement the malloc ...
yutong3195 Embedded System
Is the message delivered by the OK button on the dialog box in WIN CE IDOK?
In WIN CE, the message transmitted by the OK button on the dialog box is IDOK? I created two message functions in MFC, ON_MESSAGE(IDOK,ALLIDOK) and ON_MESSAGE(IDCANCEL,ALLCANCEL). I found that no matt...
koalaping Embedded System
VxWorks 组播sendto() error 0x41
程序设置如下:bzero ((char *)&sMAddr, sizeof (sMAddr));sMAddr.sin_len = (u_char) sizeof(sMAddr);sMAddr.sin_family = AF_INET;/*sMAddr.sin_addr.s_addr =inet_addr(MyIP);*/sMAddr.sin_addr.s_addr = INADDR_ANY;sMA...
wolfliu_67 Real-time operating system RTOS
PID Album Resource Collection
[align=center][/align][align=left][size=4]PID Control Algorithm Album:[/size][/align][align=left][size=4]([color=Red]All information can be downloaded in one click[/color]Address: [url=https://downloa...
sigma Robotics Development
Help, is there a sensor that can measure the frequency of human breathing gas? I want a small 1~2 cm
Help, is there a sensor that can measure the frequency of human breathing gas? I want a small 1~2 cm...
keyee88 Sensor

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 216  2355  659  2464  1024  5  48  14  50  21 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号