BK8-ABC-V-6-R

Description
Electric Fuse, Fast Blow, 6A, 200A (IR),
CategoryCircuit protection    Circuit protection   
File Size205KB,2 Pages
ManufacturerEaton
Download Datasheet Parametric View All

BK8-ABC-V-6-R Overview

Electric Fuse, Fast Blow, 6A, 200A (IR),

BK8-ABC-V-6-R Parametric

Parameter NameAttribute value
MakerEaton
Reach Compliance Codecompliant
Is SamacsysN
Fusing characteristicsFAST
body height32.82 mm
Body length or diameter6.76 mm
Circuit protection typeElectric Fuse
physical size6.76mm x 32.82mm
Rated breaking capacity200 A
Rated current6 A
Rated voltage250 V
GuidelineCSA, UL
Terminal shapePIN WIRE
Disconnect time or delay14400 s
Base Number Matches1
1
4
” x 1
1
4
” Glass Tube Fuses
ABC Series, Fast-Acting, Ceramic Tube
Description
• Fast-acting, ceramic tube
• Optional axial leads available
1
4
” x 1
1
4
” (6.4 x 31.7mm) physical size
• Ceramic tube, nickel-plated brass endcap construction
• UL Listed product meets standard 248-14
ELECTRICAL CHARACTERISTICS
% of Amp Rating
Opening Time
100%
4 Hours Minimum
135%
60 Minutes maximum
200%
120 Seconds Maximum
Dimensions - mm
Drawing Not to Scale
Agency Information
• UL Listed Guide JDYX & File E19180
• UL Recognition Guide JDYX2 & File E19180
• CSA Certification: Class No: 1422-01 & 1422-30,
File 53787
Environmental Data
• Shock:
1
4
A - 30A – MIL-STD-202, Method 213,
Test Condition J
• Vibration:
1
4
A - 30A – MIL-STD-202, Method 204,
Test Condition C (Except 5g, 500Hz)
Ordering
• Specify packaging, product and option code
Voltage
Ratings
Vac
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
Vdc
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
Vac Interrupting
Ratings* (amps)
250
125
35
10,000
35
10,000
35
10,000
35
10,000
100
10,000
100
10,000
100
10,000
100
10,000
200
10,000
200
10,000
200
10,000
200
10,000
200
10,000
200
10,000
750
10,000
750
10,000
400
1000
400
1000
200
1000
200
1000
* Interrupting ratings measured at 70% - 80% power factor on AC. The interrupting ratings for 18A and 20A were measured at 85% - 95% power factor on AC. The
interrupting ratings for 25A and 30A were measured at 89% power factor on AC.
** Typical DC cold resistance measured at <10% of rated current.
† Typical melting I2t measured at listed interrupting rating and rated voltage.
‡ Typical voltage drop measured at 25°C±3°C ambient temperature at rated current.
‡‡ CSA approvals for 25A and 30A are at 125Vac - IR 1000A and 125Vdc - IR 400A (IR 1000A at 75Vdc)
Part
Number
ABC-
1
4
-R
ABC-
1
2
-R
ABC-
3
4
-R
ABC-1-R
ABC-1-
1
2
-R
ABC-2-R
ABC-2-
1
2
-R
ABC-3-R
ABC-4-R
ABC-5-R
ABC-6-R
ABC-7-R
ABC-8-R
ABC-10-R
ABC-12-R
ABC-15-R
ABC-18-R
ABC-20-R
ABC-25-R
ABC-30-R
Vdc Interrupting
Ratings (amps)
125
75
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
400
1000
400
1000
Specifications
Typical
DC Cold
Resistance (Ω)**
2.950
0.587
0.300
0.1950
0.131
0.0890
0.061
0.047
0.031
0.026
0.021
0.016
0.014
0.011
0.0068
0.00553
0.00465
0.00366
0.0028
0.002225
Typical
Pre-Arc
I
2
t AC
0.0020
0.0390
0.1450
0.4310
1.1630
2.1670
4.4670
6.55
22.28
32.83
58
109.33
116.5
208.8
133.3
200.2
400
550.8
839.3
1429
Typical
Voltage
Drop (V)
0.35
0.41
0.32
0.3
0.28
0.31
0.23
0.14
0.17
0.22
0.19
0.17
0.19
0.15
0.1
0.1
0.1
0.1
0.09
0.09
Agency Approvals
UL UR CSA
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
‡‡
X X
‡‡
0613
BU-SB13635
Page 1 of 2
Data Sheet 2000
Is there any master who can help analyze this board, what are the errors, and how to draw better? Thank you~~~
Is there any master who can help analyze this board, what are the errors, and how to draw better? Thank you~~~...
熙蕾馨恋 PCB Design
Freescale 2009 seminar之八Hands-on Workshop Accelerometer Pressure Proximity
Hands-on Workshop: Accelerometer /Pressure/ Proximity Sensor Applications Using the Sensor Toolbox AUDIT II BoardsOutline 1.Top questions & application challenges 30 min 2.How to choose the most suita...
madokaaukawa NXP MCU
Question about circuit magnification
[i=s] This post was last edited by dontium on 2015-1-23 13:29 [/i] Using LM353 for amplification processing, connected to a 12v power supply, the first stage amplification factor is 500k/230=2173. The...
echozhang110 Analogue and Mixed Signal
TI NDK dual network card driver?
I would like to ask the experts who have studied TI NDK: 1. NDK supports multiple devices. Does it mean supporting multiple PHYs or multiple EMACs? If I want to support two EMACs at the same time, can...
toddhan DSP and ARM Processors
HuaDa MCU FLASH operation instructions and precautions
HuaDa MCU covers 16/32/64/128/256/512K Byte FLASH memory according to different models. Each FLASH is divided into sectors, and each sector has a capacity of 512 bytes. This memory supports erase (chi...
火辣西米秀 Domestic Chip Exchange
Who has a version before PICC9.8?
I want to play around with MCV14A recently, but the include folder of the higher version of PICC does not have the header file of MCV14A. It seems that the 9.8 version has it. If anyone has it, please...
yealien Microchip MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2457  1020  2302  1383  898  50  21  47  28  19 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号