DVHV2800D Series
HIGH RELIABILITY HYBRID
DC-DC CONVERTERS
DESCRIPTION
The DVHV series of high reliability DC-DC
converters is operable over the full military (-55 °C to
+125 °C) temperature range with no power
derating. Unique to the DVHV series are robust and
effective input and output filters which provide
dramatically reduced input and output noise
performance when compared to other manufacturers
competing devices. Operating at a nominal fixed
frequency of 475 kHz, these regulated, isolated units
utilize a high speed magnetic feedback design and
well controlled undervoltage lockout circuitry to
eliminate slow start-up problems.
These converters are designed and manufactured in
a facility qualified to ISO9001 and certified to MIL-
PRF-38534 and MIL-STD-883.
This product may incorporate one or more of the
following U.S. patents:
5,784,266
5,790,389
5,963,438
5,999,433
6,005,780
6,084,792
6,118,673
FEATURES
High Reliability
Very Low Output Noise
Wide Input Voltage Range: 15 to 50 Volts per
MIL-STD-704
Up to 15 Watts Output Power
Fault Tolerant Magnetic Feedback Circuit
NO Use of Optoisolators
Undervoltage Lockout
Indefinite Short Circuit Protection
Current Limit Protection
Industry Standard Pinout
High Input Transient Voltage: 80 Volts for 1 sec
per MIL-STD-704A
Precision Seam Welded Hermetic Package
Custom Versions Available
Additional Environmental Screening Available
Meets MIL-STD-461 Revisions C, D, E and F
EMC Requirements When Used With VPT’s
EMI Filters
Flanged and Non-flanged Versions Available.
MIL-PRF-38534 Element Evaluated
Components
Space Applications should consider VPT’s “S”
Series of Radiation Tolerant Power Conversion
Devices. Contact VPT for details.
Figure 1
– DVHV2800D / DVHV2800DF DC-DC Converter
(Exact
marking may differ from that shown)
Sales Information:
Phone: (425) 353-3010
Fax: (425) 353-4030
E-mail: vptsales@vpt-inc.com
DVHV2800D-7.0
http://www.vpt-inc.com
1
DVHV2800D Series
SPECIFICATIONS
(T
CASE
= -55°C to +125°C, V
IN
= +28V ± 5%, Full Load
5
, Unless Otherwise Specified)
ABSOLUTE MAXIMUM RATINGS
Input Voltage (Continuous)
Input Voltage (Transient, 1 second)
Output Power
1
Power Dissipation (Full Load, T
CASE
= +125°C)
ESD Rating per MIL-PRF-38534
50 V
DC
80 Volts
15 Watts
6 Watts
3A
Junction Temperature Rise to Case
Storage Temperature
Lead Solder Temperature (10 seconds)
Weight (Maximum) (Un-Flanged / Flanged)
+15°C
-65°C to +150°C
270°C
(52 / 55) Grams
Parameter
Conditions
Min
DVHV2805D
Typ
Max
Min
DVHV2812D
Typ
Max
Units
STATIC
INPUT
4
Voltage
Current
Ripple Current
Inhibit Pin Input
UVLO Turn On
UVLO Turn Off
OUTPUT
5
Voltage
4
4
4
Continuous
Transient, 1 sec
Inhibited
No Load
Full Load , 20Hz to 10MHz
5
15
-
-
-
-
0
9.0
12.0
11.0
28
-
-
-
-
-
11.0
-
-
5.0
5.0
5.0
5.0
-
-
-
-
-
-
-
-
-
-
-
-
-
475
-
-
413
50
80
6
90
50
1.5
13.0
14.8
14.5
5.05
5.075
5.075
5.10
15
10.5
2.1
30
20
200
50
200
500
-
11
11
500
550
600
-
-
15
-
-
-
-
0
9.0
12.0
11.0
11.88
11.82
11.82
11.76
0
0
0
-
-
-
-
-
-
76
-
-
-
400
500
100
-
28
-
-
-
-
-
11.0
-
-
12.0
12.0
12.0
12.0
-
-
-
-
-
-
-
-
-
-
-
-
-
475
-
-
413
50
80
6
90
50
1.5
13.0
14.8
14.5
12.12
12.18
12.18
12.24
15
10.5
0.875
40
20
200
50
200
500
-
11
11
500
550
600
-
-
V
V
mA
mA
mA
p-p
V
V
V
V
V
V
V
V
W
W
A
mV
p-p
mV
mV
mV
mV
mV
%
W
W
F
kHz
kHz
MΩ
kHrs
Inhibit Pin Open Circuit Voltage
+V
OUT
+V
OUT
-V
OUT
-V
OUT
Power
3,6
T
CASE
= 25°C
T
CASE
= -55°C to +125°C
T
CASE
= 25°C
T
CASE
= -55°C to +125°C
Either Output
Either Output
Full Load , 20Hz to 10MHz
V
IN
= 16V to 40V
V
IN
= 16V to 40V
5% Load to Full Load
5% Load to Full Load
5
5
5
4.95
4.925
4.925
4.90
0
0
0
-
-
-
-
-
-
74
-
-
-
400
500
100
-
Total
±V
OUT
±V
OUT
±V
OUT
+V
OUT
-V
OUT
+V
OUT
-V
OUT
-V
OUT
Current
3,6
Ripple Voltage
Line Regulation
Load Regulation
Cross Regulation
EFFICIENCY
+Load 70%, -Load 30%
+Load 30%, -Load 70%
Full Load
Overload
5
4
LOAD FAULT POWER DISSIPATION
CAPACITIVE LOAD
4
Short Circuit
Either Output
V
H
– V
L
= 5V, DC = 20-80%
500 V
DC
, T
CASE
= 25°C
AIF @ T
C
= 55°C
SWITCHING FREQUENCY
SYNC FREQUENCY RANGE
ISOLATION
MTBF (MIL-HDBK-217F)
See notes next page.
DVHV2800D-7.0
2
DVHV2800D Series
SPECIFICATIONS
(T
CASE
= -55°C to +125°C, V
IN
= +28V ± 5%, Full Load
5
, Unless Otherwise Specified)
ABSOLUTE MAXIMUM RATINGS
Input Voltage (Continuous)
Input Voltage (Transient, 1 second)
Output Power
1
Power Dissipation (Full Load, T
CASE
= +125°C)
ESD Rating per MIL-PRF-38534
50 V
DC
80 Volts
15 Watts
6 Watts
3A
Junction Temperature Rise to Case
Storage Temperature
Lead Solder Temperature (10 seconds)
Weight (Maximum) (Un-Flanged / Flanged)
+15°C
-65°C to +150°C
270°C
(52 / 55) Grams
Parameter
Conditions
DVHV2805D
Min
Typ
Max
Min
DVHV2812D
Typ
Max
Units
DYNAMIC
Load Step Output Transient
Load Step Recovery
Line Step Recovery
Turn On Delay
Turn On Overshoot
2
4
±V
OUT
±V
OUT
±V
OUT
Half Load to Full Load
V
IN
= 16V to 40V
V
IN
= 0V to 28V
-
-
-
-
-
-
-
-
300
300
-
-
200
400
600
500
20
25
-
-
-
-
-
-
-
-
500
300
-
-
300
500
900
500
20
50
mV
PK
Sec
mV
PK
Sec
mSec
mV
PK
Line Step Output Transient
2, 4
Notes:
1.
2.
3.
4.
5.
6.
Dependant on output voltage.
Time for output voltage to settle within 1% of its nominal value.
Derate linearly to 0 at 135°C.
Verified by qualification testing.
Half load at +V
OUT
and half load at –V
OUT
.
Up to 70% of the total power or current can be drawn from any one of the two outputs.
DVHV2800D-7.0
3
DVHV2800D Series
SPECIFICATIONS
(T
CASE
= -55°C to +125°C, V
IN
= +28V ± 5%, Full Load
5
, Unless Otherwise Specified)
ABSOLUTE MAXIMUM RATINGS
Input Voltage (Continuous)
Input Voltage (Transient, 1 second)
Output Power
1
Power Dissipation (Full Load, T
CASE
= +125°C)
ESD Rating per MIL-PRF-38534
50 V
DC
80 Volts
15 Watts
6 Watts
3A
Junction Temperature Rise to Case
Storage Temperature
Lead Solder Temperature (10 seconds)
Weight (Maximum) (Un-Flanged / Flanged)
+15°C
-65°C to +150°C
270°C
(52 / 55) Grams
Parameter
Conditions
Min
DVHV2815D
Typ
Max
Units
STATIC
INPUT
4
Voltage
Current
Ripple Current
Inhibit Pin Input
UVLO Turn On
UVLO Turn Off
OUTPUT
5
Voltage
4
4
4
Continuous
Transient, 1 sec
Inhibited
No Load
Full Load , 20Hz to 10MHz
5
15
-
-
-
-
0
9.0
12.0
11.0
28
-
-
-
-
-
11.0
-
-
15.0
15.0
15.0
15.0
-
-
-
-
-
-
-
-
-
-
-
-
-
475
-
-
413
50
80
6
90
50
1.5
13.0
14.8
14.5
15.15
15.225
15.225
15.30
15
10.5
0.7
40
20
200
50
200
500
-
11
11
500
550
600
-
-
V
V
mA
mA
mA
p-p
V
V
V
V
V
V
V
V
W
W
A
mV
p-p
mV
mV
mV
mV
mV
%
W
W
F
kHz
kHz
MΩ
kHrs
Inhibit Pin Open Circuit Voltage
+V
OUT
+V
OUT
-V
OUT
-V
OUT
Power
3,6
T
CASE
= 25°C
T
CASE
= -55°C to +125°C
T
CASE
= 25°C
T
CASE
= -55°C to +125°C
Either Output
Either Output
Full Load , 20Hz to 10MHz
V
IN
= 16V to 40V
V
IN
= 16V to 40V
5% Load to Full Load
5% Load to Full Load
5
5
5
14.85
14.775
14.775
14.70
-
-
-
-
-
-
-
-
-
77
-
-
-
400
500
100
-
Total
±V
OUT
±V
OUT
±V
OUT
+V
OUT
-V
OUT
+V
OUT
-V
OUT
-V
OUT
Current
3,6
Ripple Voltage
Line Regulation
Load Regulation
Cross Regulation
EFFICIENCY
+Load 70%, -Load 30%
+Load 30%, -Load 70%
Full Load
Overload
5
4
LOAD FAULT POWER DISSIPATION
CAPACITIVE LOAD
4
Short Circuit
Either Output
V
H
– V
L
= 5V, DC = 20-80%
500 V
DC
, T
CASE
= 25°C
AIF @ T
C
= 55°C
SWITCHING FREQUENCY
SYNC FREQUENCY RANGE
ISOLATION
MTBF (MIL-HDBK-217F)
See notes next page.
DVHV2800D-7.0
4
DVHV2800D Series
SPECIFICATIONS
(T
CASE
= -55°C to +125°C, V
IN
= +28V ± 5%, Full Load
5
, Unless Otherwise Specified)
ABSOLUTE MAXIMUM RATINGS
Input Voltage (Continuous)
Input Voltage (Transient, 1 second)
Output Power
1
Power Dissipation (Full Load, T
CASE
= +125°C)
ESD Rating per MIL-PRF-38534
50 V
DC
80 Volts
15 Watts
6 Watts
3A
Junction Temperature Rise to Case
Storage Temperature
Lead Solder Temperature (10 seconds)
Weight (Maximum) (Un-Flanged / Flanged)
+15°C
-65°C to +150°C
270°C
(52 / 55) Grams
Parameter
Conditions
DVHV2815D
Min
Typ
Max
Units
DYNAMIC
Load Step Output Transient
Load Step Recovery
Line Step Recovery
Turn On Delay
Turn On Overshoot
2
4
±V
OUT
±V
OUT
±V
OUT
Half Load to Full Load
V
IN
= 16V to 40V
V
IN
= 0V to 28V
-
-
-
-
-
-
-
-
500
300
-
-
350
500
900
500
20
50
mV
PK
Sec
mV
PK
Sec
mSec
mV
PK
Line Step Output Transient
2, 4
Notes:
1.
2.
3.
4.
5.
6.
Dependant on output voltage.
Time for output voltage to settle within 1% of its nominal value.
Derate linearly to 0 at 135°C.
Verified by qualification testing.
Half load at +V
OUT
and half load at –V
OUT
.
Up to 70% of the total power or current can be drawn from any one of the two outputs.
DVHV2800D-7.0
5