EEWORLDEEWORLDEEWORLD

Part Number

Search

240-790-043PK-9P9ECCPA

Description
D Type Connector, 9 Contact(s), Male, Solder Terminal, Receptacle,
CategoryThe connector    The connector   
File Size259KB,6 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

240-790-043PK-9P9ECCPA Overview

D Type Connector, 9 Contact(s), Male, Solder Terminal, Receptacle,

240-790-043PK-9P9ECCPA Parametric

Parameter NameAttribute value
Reach Compliance Codeunknown
Is SamacsysN
Other featuresSTANDARD: MIL-STD-2120
Body/casing typeRECEPTACLE
Connector typeOTHER D TYPE CONNECTOR
Contact point genderMALE
DIN complianceNO
empty shellNO
Filter functionYES
IEC complianceNO
MIL complianceYES
Mixed contactsNO
Installation typeBOARD
OptionsGENERAL PURPOSE
Shell materialALUMINUM ALLOY
Termination typeSOLDER
Total number of contacts9
Base Number Matches1
Vertical PCB Mount with Straight PC Tails
How To Order Filter Series 79 Connectors
Sample Part Number
Series
Contact Type
Insert Arrangement
Shell Material/Finish
Filter Type
Filter Class
Mating Hardware Options
PC Tail Length
240-790-043
P
- Pin Contacts
(See Table I)
Aluminum Shell
ME
- Electroless Nickel
MT
- Nickel-PTFE
E
- Chem Film
Z2
- Gold
UC
- Zinc Cobalt with Black Chromate
J
- Cadmium with Yellow Chromate
NF
- Cad/O.D. over Electroless Nickel
C
- C Filter
P
- Pi Filter
X, Y, Z, A, B, C, D, E, F, G, J
(See Table II)
P
- Jackposts
N
- No Mating Hardware (See Table)
A
- .125" (3.18)
B
- .250" (6.35)
C
- .375" (9.53)
240-790-043
Series 79 Filtered Receptacle
G
Series 79
Micro-Crimp
PC Tail Contacts
240-790-043
P
H-66 ME
P
D
P
A
Interfacial Seal
Contact Pin
Shell
Notes
1. Assembly to be identified with Glenair’s name, part number,
and date code, space permitting
2. EMI Filtered receptacle connector designed to meet
requirements of MIL-STD-2120 and Glenair Series 79
specifications. Unless otherwise specified herein, refer to
Glenair specification 799-008 for additional performance
characteristics.
3. All contacts to have identical filter value. Other filter
arrangements available, contact factory
4. Dielectric Withstanding Voltage: 500 VDC (Filter Class X, Y, Z
are 250 VDC)
5. See pages G-26 to G-31 for PCB hole patterns
6. Insulation Resistance: 5,000 megohms @ 200 VDC
7. Current Carrying Capacity
23 Gage - 5 Amps max. for all layouts
16 Gage - 7.5 Amps max. for combo layouts / 13 Amps max. for
all-power layouts
12 Gage - 13 Amps max. for combo layouts / 23 Amps max. for
all-power layouts
8. Other filter styles (C-L, L-C, Unbalanced Pi, Multi-Stage,
Multi-Value) are available. Please consult factory with your
requirements.
Materials/Finishes:
Insulators - High Grade Rigid Dielectric / N.A.
Interfacial Seal - Fluorosilicone Elastomer / N.A.
Contacts - Copper Alloy / 50 microinches Gold over Nickel
Mating Hardware - 300 Series Stainless Steel / Passivated
© 2013 Glenair, Inc.
Dimensions in inches (millimeters) and are subject to change without notice.
U.S. CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC.
1211 AIR WAY
GLENDALE, CA 91201-2497
818-247-6000
FAX 818-500-9912
www.glenair.com
G-14
E-Mail: sales@glenair.com
[Learn Power from TI] Series-----TI Standard Analog Linear Device Guide
[align=left][color=#000000][font=Times New Roman] Power management products from Texas Instruments (TI) continue to provide optimized power solutions for portable and AC-powered designs. Traditional a...
qwqwqw2088 Analogue and Mixed Signal
How to stop the inverter?
For fans of 55KW and above, without a braking resistor, what are the differences in the inverter's parking methods? Can both free parking and normal parking operate normally? Will free parking damage ...
eeleader Industrial Control Electronics
Please help me take a look at this old mechanical watt-hour meter
Which side is the input and which side is the output? How to distinguish the live wire from the neutral wire? What is the minimum current of this electric meter? Why does it stop turning and not respo...
wangfuchong Test/Measurement
Xintang MCU NUC230 series CAN bus filter and mask configuration
Is there anyone who has used Xintang MCU? This is my first time using Xintang MCU. I don’t know how to configure the CAN bus filter and mask. If you have used it, please give me some advice....
mzb2012 MCU
Please tell me how to use JLINK to debug STM32 under IAR.
Development environment: IAR4.42+JLINK V6 (full function)+EK-STM32F. Question: 1. In JLINK debugging mode, under JTAG interface, how many breakpoints can be set in FLASH? 2. In JLINK debugging mode, u...
riscbbs stm32/stm8
Standard Chartered Bank Personal Unsecured Loan
Standard Chartered Bank Personal Unsecured Unsecured Loan Loan Amount: 8000--200,000 Loan Term: 6 months-- 4 years Loan Requirements: 1. 22-60 years old 2. Work in Shanghai, and work for the current c...
梦里飘 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1738  364  696  1787  1630  35  8  15  36  33 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号