HT13G ........ HT18G
1.0 Amp. Glass Passivated Ultrafast Recovery Rectifier
Voltage
200V to 1000V
Current
1.0 A
R
DO-41 Mini
FEATURES
Ultrafast recovery time for high efficiency
Low power losses
Low forward voltage drop
High forward surge current capability
Solder dip 260ºC, 10s
AEC-Q101 qualified
Component in accordance to RoHS 2011/65/EU
and WEEE 2002/96/EC
Meets MSL level 1, per J-STD-020, LF maximum
peak of 260º C
MECHANICAL DATA
Case
:
DO-41 Mini. Epoxy meets UL 94V-0
flammability rating.
Polarity
:
Color band denotes cathode end.
Terminals
:
Matte tin plated leads, solderable per
MIL-STD-750 Method 2026, J-STD-002 and JESD22-B102.
Consumer grade, meets JESD 201 class 1A whisker test.
TYPICAL APPLICATIONS
Used in high frequency rectifier of switching mode power
supplies, inverters, freewheeling diodes, dc-to-dc converters,
and other power switching application.
Maximun Ratings and Electrical Characteristics at 25 °C
Marking Code
V
RRM
V
RMS
V
DC
Maximum Recurrent Peak Reverse Voltage (V)
Maximum RMS Voltage (V)
Maximum DC Blocking Voltage (V)
Maximum Average Forward Rectified Current
9.5mm Lead Length @ T
A
= 55 °C
Peak Forward Surge Current, 8.3 ms Single
Half Sine-wave Superimposed on Rated Load
(JEDEC Method)
HT13G
200
140
200
HT15G
400
280
400
HT16G
600
420
600
1.0 A
HT17G
800
560
800
HT18G
1000
700
1000
I
F(AV)
I
FSM
t
rr
C
j
T
j
T
stg
30 A
50 ns
15 pF
-65 to +150 °C
-65 to +150 °C
75 ns
10 pF
Maximum Reverse Recovery Time from
I
F
= 0.5A; I
R
= 1A; I
RR
= 0.25A
Typical Junction Capacitance at 1 MHz
and reverse voltage of 4V
DC
Operating Temperature Range
Storage Temperature Range
Electrical Characteristics at Tamb = 25 °C
V
F
I
R
R
th (j-a)
Maximum Instantaneous Forward Voltage @ I
F
= 1.0 A
Maximum DC Reverse Current @ Ta = 25 °C
at Rated DC Blocking Voltage @ Ta =125°C
Typical Thermal Resistance
(See note)
1.0 V
1.3 V
5 µA
150 µA
95 °C/W
1.7 V
NOTE: Mount on Cu-Pad size 5mm x 5mm on PCB.
www.fagorelectronica.com
Document Name: ht1g
Revision: 1
Version: Jun-16
Page Number: 1/4
HT13G ........ HT18G
1.0 Amp. Glass Passivated Ultrafast Recovery Rectifier
Ordering information
PREFERRED P/N
HT15G AMP
HT15G TR
PACKAGE CODE
AMP
TR
DELIVERY MODE
AMMO BOX
13" diameter tape and reel
BASE QUANTITY
3,000
5,000
UNIT WEIGHT (g)
0.20
0.20
Package Outline Dimensions: (mm) DO-41 Mini
2.7
2.0
DIA.
25.4 MIN
3.3
3.0
0.64
0.53
DIA.
25.4 MIN
www.fagorelectronica.com
Document Name: ht1g
Revision: 1
Version: Jun-16
Page Number: 2/4
HT13G ........ HT18G
1.0 Amp. Glass Passivated Ultrafast Recovery Rectifier
Ratings and Characteristics
(Ta 25 ºC unless otherwise noted)
I
F
, instantaneous forward current (A)
TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTIC
MAXIMUM FORWARD CURRENT DERATING
CURVE
I
F(AV)
, average forward current (A)
100
10
HT1
5G
2.0
Single Phase Half Wave 60Hz
Resistive or Inductive Load
9.5mm Lead Length
1
1.0
0.1
0.01
HT13G
HT16G-HT18G
0
0.2
V
F
, forward voltage (V)
0.4
0.6
0.8
1.0
1.2
1.4
0
0
Tamb, ambient temperature (°C)
25
50
75
100
125
150
175
I
FSM
, peak forward surge current (A)
MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
35
30
25
20
15
10
0
1
2
5
10
20
50
100
8.3ms Single Half Sine Wawe
JEDEC Method
TYPICAL JUNCTION CAPACITANCE
Cj, junction capacitance (pF)
40
70
60
50
40
30
20
10
0
0.1
0.5 1 2
5 10 20 50 100 200
800
HT
13
G-
H
T1
HT16
5G
G-HT
18G
T
j
= 25 °C
Number of cycles at 60 Hz
V
R
, reverse voltage (V)
TYPICAL REVERSE CHARACTERISTIC
1000
I
R
, Instantaneous reverse
current (µA)
REVERSE RECOVERY TIME CHARACTERISTIC AND TEST CIRCUIT DIAGRAM
50W
NON INDUCTIVE
10W
NON INDUCTIVE
+0.5A
DUT
(-)
PULSE
GENERATOR
(NOTE 2)
(+)
trr
100
10
1
T
j
= 125 °C
T
j
= 75 °C
(+)
50vDC
(APPROX)
(-)
0
-0.25A
1W
NON
INDUCTIVE
OSCILLOSCOPE
(NOTE 1)
T
j
= 25 °C
-1.0A
NOTES: 1. Rise Time = 7ns max. Input Impedance =
1 megohm 22 pf
2. Rise Time = 10 ns max. Sourse Impedance =
50 ohms
1cm
SET TIME BASE FOR
5/ 10ns/ cm
0.1
0
20
40
60
80
100
120
140
Percent of rated peak reverse voltage (%)
www.fagorelectronica.com
Document Name: ht1g
Revision: 1
Version: Jun-16
Page Number: 3/4
HT13G ........ HT18G
1.0 Amp. Glass Passivated Ultrafast Recovery Rectifier
Revision History
Date
15-May-2008
29-Jun-2016
Revision
0
1
Original Data Sheet
Format update
Description of Changes
Disclaimer
All product, product specifications and data are subject to change without notice to improve reliability,
function or design or otherwise.
Fagor Electrónica, S.Coop., its affiliates, agents, and employees, and all persons acting on its or their
behalf (collectively, "Fagor"), disclaim any and all liability for any errors, inaccuracies or incompleteness contained
in any datasheet or in any other disclosure relating to any product.
Fagor makes no warranty, representation or guarantee regarding the suitability of the products for any particular
purpose or the continuing production of any product. To the maximum extent permitted by applicable law,
Fagor disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all
liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied
warranties, including warranties of fitness for particular purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Fagor's knowledge
of typical requirements that are often placed on Fagor products in generic applications. Such statements are not
binding statements about the suitability of products for a particular application. It is the customer's responsibility
to validate that a particular product with the properties described in the product specification is suitable for use in a
particular application. Parameters provided in datasheets and/or specifications may vary in different applications
and performance may vary over time. All operating parameters, including typical parameters, must be validated
for each customer application by the customer's technical experts. Product specifications do not expand or
otherwise modify Fagor's terms and conditions of purchase, including but nos limited to the warranty expressed
therein.
Except as expressly indicated in writing. Fagor products are not designed for use in medical, life-saving, or
life-sustaining applications or for any other application in which the failure of the Fagor product could result in
personal injury or death. Customers using or selling Fagor products not expressly indicated for use in such
applications do so at their own risk and agree to fully indemnify and hold Fagor and its distributors harmless from
and against any and all claims, liabilities, expenses and damages arising or resulting in connection with such use
or sale, including attomeys fees, even if such claim alleges that Fagor or its distributor was negligent regarding
the design or manufacture of the part. Please contact authorized Fagor personnel to obtain written terms and
conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this
document or by any conduct of Fagor, Product names and markings noted herein may be trademarks of their
respective owners.
www.fagorelectronica.com
Document Name: ht1g
Revision: 1
Version: Jun-16