EEWORLDEEWORLDEEWORLD

Part Number

Search

SSB7TF15120011

Description
20A, BARRIER STRIP TERMINAL BLOCK, 1 ROW, 1 DECK, ROHS COMPLIANT
CategoryThe connector    terminals   
File Size800KB,4 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Environmental Compliance  
Download Datasheet Parametric View All

SSB7TF15120011 Overview

20A, BARRIER STRIP TERMINAL BLOCK, 1 ROW, 1 DECK, ROHS COMPLIANT

SSB7TF15120011 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
package instructionROHS COMPLIANT
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresSTANDARD: UL94V-2, POLYPROPYLENE
Fastening methodSCREW
Manufacturer's serial numberSSB7
Installation typeBOARD
Number of layers1
Rows1
Number of channels15
Rated current20 A
Rated voltage600 V
safety certificateUL; CSA
Terminal and terminal strip typesBARRIER STRIP TERMINAL BLOCK
Wire gauge12 AWG
Base Number Matches1
Note:
All part numbers
are RoHS Compliant.
BUCHANAN Terminal Blocks
0.4375” [11.1] Pitch, Series SSB7
SSB7FP##0202
Binding Head
Scew
Material & Finish
Housing Material—Polypropylene
Flammability—UL94V-2
Color—Black
Terminals—Brass,
bright acid tin over
copper plating
Screw—#6-32
Steel with zinc +
chromate plating
Barrier Strips
Mechanical Properties
Pitch (Terminal Spacing)—
.4375 in. [11.1]
Recommended PCB Hole Dia.—
.077" [1.955]
Wire Strip Length—.38"
[9.652]
Recommended Tightening
Torque—8
in-lbs.
Recommended Screwdrivers—
Stanley 1006-4, Sears Craftsman 41581,
Any #2 Phillips-Head
Wire Lug Width (Max.)—8.1mm
[.320 in.]
2
Circuits
(not positions)
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
C1
in.
0.44
0.88
1.31
1.75
2.19
2.63
3.06
3.50
3.94
4.38
4.81
5.25
5.69
6.13
6.56
7.00
7.44
7.88
8.31
8.75
9.19
9.63
10.06
10.50
10.94
11.38
L1*
in.
1.00
1.44
1.88
2.31
2.75
3.19
3.63
4.06
4.50
4.94
5.38
5.81
6.25
6.69
7.13
7.56
8.00
8.44
8.88
9.31
9.75
10.19
10.63
11.06
11.50
11.94
C2
in.
0.88
1.31
1.75
2.19
2.63
3.06
3.50
3.94
4.38
4.81
5.25
5.69
6.13
6.56
7.00
7.44
7.88
8.31
8.75
9.19
9.63
10.06
10.50
10.94
11.38
L2*
in.
1.44
1.88
2.31
2.75
3.19
3.63
4.06
4.50
4.94
5.38
5.81
6.25
6.69
7.13
7.56
8.00
8.44
8.88
9.31
9.75
10.19
10.63
11.06
11.50
11.94
Electrical Properties
Ratings—UL
Class B 20 Amps, 600V
UL Class C 20 Amps, 600V
CSA Type C 20 Amps, 300V
CSA Type D, 5 Amps, 600V
Wire Range—12-22
AWG
Dielectric Withstand—5000V
Environmental Properties
Operating Temperature Range—-
60°C to +105°C [-76°F to +221°F]
Computing Barrier Block
Lengths
Direct Mounting—Use
C1 and L1 for
P & H mounting options
End Position Mounting—Use
L2 and
C2 for M, E, F & G mounting options
LR25557
E63810
151
Catalog 1308389
Revised 6-07
www.tycoelectronics.com
Dimensions are in millimeters
and inches unless otherwise
specified.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA: 1-800-522-6752
Canada: 1-905-470-4425
Mexico: 01-800-733-8926
C. America: 52-55-1106-0803
South America: 55-11-2103-6000
Hong Kong: 852-2735-1628
Japan: 81-44-844-8013
UK: 8706-080-208
Design of transformers in resonant converters.
...
czf0408 Power technology
Stepper motor and its drive control system
Stepper motor and its drive control system...
lygen2009 MCU
Can the hive registry be stored in another partition?
Now the nandflash is 256MB, one partition is binfs and the other is exfat. How to save the hive registry in exfat? binfs may re-burn nk.bin. Now the registry is as follows: [HKEY_LOCAL_MACHINE\Drivers...
atom1212 Embedded System
Please tell me why the 5V can't be turned off in this picture
[i=s]This post was last edited by sky999 on 2020-8-2 10:30[/i]This diagram was originally normal, but after adding the Q6 circuit, the 5V above can never be turned off. Why? It is normal if there is n...
sky999 PCB Design
10 Tips for Learning Embedded Systems
Now, there seems to be a nationwide movement to learn embedded systems in China. However, it is understood that many people have encountered great obstacles in their learning due to the lack of certai...
bootloader Embedded System
[MSP430 Sharing] Online Configuration Design of Automatic Monitoring System Based on Configuration Mode
While introducing the current development of the entire remote automation monitoring system, this paper briefly introduces the structure of the power environment remote monitoring system and discusses...
鑫海宝贝 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2826  1058  1246  1199  2248  57  22  26  25  46 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号