EEWORLDEEWORLDEEWORLD

Part Number

Search

HGN-375A03S-40-1MM3

Description
Mains Power Connector, 3A, 125/250VAC, Male, Solder Terminal, Socket
CategoryThe connector    The connector   
File Size485KB,3 Pages
ManufacturerPower Dynamics, Inc.
Websitehttp://www.powerdynamics.com/
Environmental Compliance  
Download Datasheet Parametric View All

HGN-375A03S-40-1MM3 Overview

Mains Power Connector, 3A, 125/250VAC, Male, Solder Terminal, Socket

HGN-375A03S-40-1MM3 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Reach Compliance Codecompliant
Other featuresSTANDARDS: IEC 60320; UL; VDE
Body/casing typeSOCKET
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
MIL complianceNO
Power Connector Ratings3A, 125/250VAC
Manufacturer's serial numberHGN-375
Installation typePANEL
OptionsGENERAL PURPOSE
Termination typeSOLDER
Total number of contacts3
Base Number Matches1
HGN-375(A, B, C)
FUSED WITH ON/OFF SWITCH, IEC 60320 POWER INLET
SOCKET WITH FUSE/S (5X20MM)
MECHANICAL DIMENSIONS
(Unit: mm)
CASE A
49.83
60.71
55.04
65.4
Use only with a 250V Fuse
Employer uniqement avec
un fusible de 250V
60.0
O
32.45
-
40 + 0.2
3.5
49.37
2x M3
61.5
CASE B
FEATURES
2x 3.3
The HGN-375(A, B, C) series offers filters in three different
package styles - Flange mount (sides), Flange mount (top/
bottom), & snap-in type. This cost effective series offers more
component options with better performance in curbing
common and differential mode noise. These filters are
equipped with IEC connector, fuse holder for one or two 5 x
20 mm fuses, 2 pole on/off switch and fully enclosed metal
housing.
These filters are also available for Medical equipment with
low leakage current and have been designed to bring various
medical equipments into compliance with EN55011 and FCC
Part 15J, Class B conducted emissions limits.
82
72
Use only with a 250V fuse
Employer uniquement avec
un fusible de 250V
28.5
4x R0.5
6.30 TYP.
-
40.0+ 0.2
RECOMMENDED PANEL CUTOUT
(MOUNT FROM FRONT)
R2.5 TYP.
2x 3.5
29.3
+0.5
60.8
+0.5
72.0
+0.1
29 6.3 TYP.
29.5
59.8
48.7
(3.5)
APPLICATIONS
Computer & networking equipment, Measuring & control
equipment, Data processing equipment, laboratory instruments,
Switching power supplies, other electronic equipment.
CASE C
(61.3)
(56.2)
TECHNICAL DATA
Rated Voltage: 125/250VAC
Rated Current: 1A, 2A, 3A, 4A, 6A, 10A
Power Line Frequency: 50/60Hz
Max. Leakage Current each
Line to Ground:
@ 115VAC 60Hz: 0.5mA, max
@ 250VAC 50Hz: 1.0mA, max
@ 125VAC 60Hz: 2
µ
A*, max
@ 250VAC 50Hz: 5
µ
A*, max
Hipot Rating (one minute)
Line to Ground: 2250VDC
Line to Line: 1450VDC
Temperature Range: -25C to +85C
* Medical application
65 59.5
Use only with a 250V fuse
Employer uniquement avec
un fusible de 250V
59.8
28
32
SUGGESTED PANEL CUTOUT
(MOUNTING FROM FRONT)
THICKNESS OF PANEL IS FROM
1.00mm to 1.6mm
48.7
(3.5)
R2.5 TYP.
29.3
+0.5
29 6.3 TYP.
61.4
+0.3
Specifications subject to change without notice. Dimensions (mm). See Appendix A for
recommended power cord. See PDI full line catalog for detailed specifications on power cords.
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: filtersales@powerdynamics.com •
www.powerdynamics.com
81
Simulation Applications Journal 2013, 2nd Quarter
...
gaoyang9992006 Analog electronics
A: Boss, please help me. Urgent``````````````````````!
[b]I am in a hurry to post this because my friends need it urgently, but I don't know how to upload files in the reply. These materials are just average, please don't waste your time[/b]. Take a look ...
njdyp MCU
Looking to buy ATSAMC21 series or ATSAME70 series evaluation board
As the title says, if you have spare space, please contact us!...
lzgztm521 Buy&Sell
Some experience in PCB design
1. When connecting more than 3 points, try to let the lines pass through each point in turn to facilitate testing, and keep the line as short as possible, as shown in the following figure (according t...
settleinsh FPGA/CPLD
There is a small bug in the reply prompt~
I often find that the supplementary content in my own topic posts, that is, my own replies to myself, also have reply prompts, which feels a bit strange. I think this should also be a bug~~...
辛昕 Suggestions & Announcements
Why does IIS only play mono music?
[i=s]This post was last edited by lzwml on 2015-8-15 19:58[/i] Platform: TQ2440, peripheral UDA1341 Use ttplayer to convert mp3 to wav format. The computer plays dual channels. After downloading to th...
lzwml ARM Technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 812  1606  2627  1619  2382  17  33  53  48  28 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号