EEWORLDEEWORLDEEWORLD

Part Number

Search

B383412L2

Description
Barrier Strip Terminal Block, 50A, 1 Row(s), 1 Deck(s)
CategoryThe connector    terminals   
File Size239KB,2 Pages
ManufacturerEaton
Download Datasheet Parametric View All

B383412L2 Overview

Barrier Strip Terminal Block, 50A, 1 Row(s), 1 Deck(s)

B383412L2 Parametric

Parameter NameAttribute value
Reach Compliance Codecompliant
ECCN codeEAR99
Other features94V-0
Fastening methodSCREW
Manufacturer's serial numberB38
Number of layers1
Rows1
Number of channels12
Rated current50 A
Rated voltage600 V
safety certificateUL; CSA; CE
Terminal and terminal strip typesBARRIER STRIP TERMINAL BLOCK
Wire gauge10 AWG
Base Number Matches1
INDEX
Series A38 / B38
Single Row Terminal Blocks
SPECIFICATIONS
Rating:
A38: 30A, 600V
B38: 50A, 600V
Center Spacing:
.437” (11.10 mm)
Wire Size:
#10-22 AWG CU
Screw Size:
#8-32 Zinc Plated Steel
Torque Rating:
A38: 9 in-lb; B38: 15 in-lb
Distance Between Barriers:
.378” (9.60mm)
Operating Temperature:
221°F (105°C)
Molded Material:
Black, UL Rated 94VO Thermoplastic
Breakdown Voltage:
5000V rms
Recommended PCB Hole Diameter (A38):
.076” (1.93mm)
Approvals:
UL E62622; CSA LR15364; CE Certified
TABLE A
MOUNTING
ENDS ONLY
Poles
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
B
Mount Ctrs.
1.31
1.75
2.19
2.62
3.06
3.50
3.93
4.37
4.81
5.24
5.68
6.12
6.56
6.99
7.43
“A”
Dim. Length
1.67
2.10
2.54
2.98
3.41
3.85
4.29
4.72
5.16
5.60
6.04
6.47
6.91
7.35
7.78
BARRIER
ENDS ONLY
“A”
Dim. Length
0.93
1.37
1.81
4.05
2.68
3.12
3.56
3.99
4.43
4.87
5.30
5.74
6.18
6.61
7.05
A382208
B381404
Series A38
"A" DIM.
"B" DIM.
HOLE SIZE
.20
(5.0)
11.10
(.437)
.80
(20.4)
* Dimensions in inches. To convert to millimeters, multiply by 25.4.
.28
(7.0)
Series B38
"A" DIM.
.437
(11.10)
.65
(16.4)
.21
(5.2)
.25
(6.4)
Cooper Bussmann
l
7300 W. Wilson Ave
l
Chicago, IL 60656-4708
l
Fax: 708-867-2211
l
Phone: 708-867-4600
Website: http://www.busscc.com
19
Wince serial communication
I wrote a serial communication tool. When I debugged it with VS2005, the received data was correct. But when it ran normally, the received data was wrong. For example: Source data: 1234567 1234567 ......
lhzisname Embedded System
Timing Analysis and Timing Constraints
Timing Analysis and Timing Constraints...
tonytong MCU
How to use E-coins?
How to use E coins? Can I buy things? Are you referring to development boards? How to operate?...
cl17726 Suggestions & Announcements
After the stepper motor is powered on according to the timing, it just shakes left and right and does not rotate. I would like some guidance.
The stepper motor runs in full step mode, and the delay has been tried in the range of 5ms--50ms. Only the sound changes, but the operation does not change. I have been wondering if there is a problem...
Bjdj Motor Drive Control(Motor Control)
DA double buffering method
[i=s]This post was last edited by paulhyde on 2014-9-15 09:43[/i] How should I program the DA double buffering method? Why can't I transfer data?...
liu5013 Electronics Design Contest
There was an error when installing MySQL, please help me solve it!
When I was installing MySQL, an error occurred: %pre(MySQL-server-community-5.1.60-1.rhel4) scriptlet failed, exit status 1 error: install: %pre scriptlet failed (2), skipping MySQL-server-community-5...
lw209 Linux and Android

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2100  1761  2874  1339  1463  43  36  58  27  30 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号