389FXBXC1-12D

Description
Electromechanical Relay, DPDT, 13A (Contact), 28VDC (Contact), AC/DC Output,
CategoryMechanical and electronic products    relay   
File Size989KB,6 Pages
ManufacturerSchneider
Environmental Compliance
Download Datasheet Parametric View All

389FXBXC1-12D Online Shopping

Suppliers Part Number Price MOQ In stock  
389FXBXC1-12D - - View Buy Now

389FXBXC1-12D Overview

Electromechanical Relay, DPDT, 13A (Contact), 28VDC (Contact), AC/DC Output,

389FXBXC1-12D Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Reach Compliance Codeunknow
ECCN codeEAR99
body width38 mm
body height35 mm
Body length or diameter70.2 mm
Coil resistance100 Ω
Nominal coil voltage12 V
Coil/Input Power TypeAC/DC
Contact (AC) maximum rated power R load3.5VA@300VAC
Contact (AC) maximum rated R load25A@300VAC
Maximum contact current (AC)25 A
Maximum contact current (DC)13 A
Contact (DC) maximum rated power R load1.5W@28VDC
Contact (DC) maximum rated R load13A@28VDC
Maximum contact voltage (AC)300 V
Maximum contact voltage (DC)28 V
Contact/Output Power TypeAC/DC
Dielectric strength between coil and contacts2200 Vrms
Dielectric strength between breaking contacts1600 Vrms
Electrical life50000 Cycle(s)
End contact materialSilver Alloy
Number of terminals8
operating hours20 ms
Maximum operating temperature55 °C
Minimum operating temperature-30 °C
physical size70.2mm x 38mm x 35mm
Relay style2 FORM C
Relay functionDPDT
Termination typeQUICK CONNECT
weight96 g
Base Number Matches1
Description
Magnecraft Power Relays
389F
SPST, 30 A; DPDT, 20 to 25 A;
SPDT, 25 to 30 A; 3PDT, 20 A
Description
The 389F series power relays offer a broad range of contact ratings along with a
variety of panel, DIN and socket mount options and accessories, making it the ideal
solution for a variety of application requirements½
Feature
High-power contacts
Benefit
High contact ratings (up to 30 A, 1½5 hp) and
long electrical endurance; suitable for high-power
switching applications
Ideal for lighting controls
Meets a wide variety of applications
Helps increase design and installation flexibility;
allows the use of modules and other accessories
Environmentally friendly; Complies with the
European Restriction of Hazardous Substances
directive
Ballast load ratings
Plug-In (Socket) Cover
Multiple contact configurations
Socket mountable (plug-in cover only)
RoHS compliant
Side Flange Cover
Rated Contact
Current
Contact
Configuration
Coil Voltage
24 Vac
120 Vac
Coil Resistance (Ω)
72
1700
7200
100
400
72
1700
7200
100
400
1700
100
400
1700
100
400
1700
400
Cover Style
Plug-in (socket)
Plug-in (socket)
Side flange
Side flange
Side flange
Plug-in (socket)
Side flange
Plug-in (socket)
Side flange
Plug-in (socket)
Side flange
Side flange
Side flange
Plug-in (socket)
Side flange
Side flange
Side flange
Side flange
Side flange
Side flange
Side flange
Side flange
Side flange
Standard Part Number
389FXCXC-24A
389FXCXC-120A
389FXCXC1-120A
389FXCXC1-240A
389FXCXC1-12D
389FXCXC-24D
389FXCXC1-24D
389FXBXC-24A
389FXBXC1-24A
389FXBXC-120A
389FXBXC1-120A
389FXBXC1-240A
389FXBXC1-12D
389FXBXC-24D
389FXBXC1-24D
389FXAXC1-120A
389FXAXC1-12D
389FXAXC1-24D
389FXHXC1-120A
389FXHXC1-12D
389FXHXC1-24D
389FHXXC1-120A
389FHXXC1-24D
20 A
3PDT
240 Vac
12 Vdc
24 Vdc
24 Vac
120 Vac
DPDT
25 A
240 Vac
12 Vdc
24 Vdc
SPDT
SPDT-DM-DB
30 A
SPST-NO-DM
120 Vac
12 Vdc
24 Vdc
120 Vac
12 Vdc
24 Vdc
120 Vac
24 Vdc
Part Number Explanation
Series:
389F
Contact
Arangement:
XAX =
SPDT
XBX =
DPDT
XCX =
3PDT
XHX =
SPDT-DM-DB
HXX =
SPST-NO-DM
Cover Style:
C =
Plug-in socket mount
C1 =
Side flange mount
Coil Voltage:
12A =
12 Vac
24A =
24 Vac
48A =
48 Vac
120A =
120 Vac
240A =
240 Vac
12D =
12 Vdc
24D =
24 Vdc
48D =
48 Vdc
110D =
110 Vdc
14
For NPN tubes, the c and e poles of U(br)ceo are both N-type, so where does the reverse statement come from?
For NPN tubes, the c and e poles of Ubrceo are both N-type, so where does the reverse statement come from? Another question is, are U(br)ceo and Uceo the same thing?...
深圳小花 MCU
MCU simulation problem
I am now doing a MCU simulation. The input data is correct, but after a while of simulation, the digital tube display will show garbled characters. What could this be? How can I solve it? Please help ...
yeming Embedded System
Java Training Brand Road
Brand is the foundation of survival, and brand effect reflects competitiveness. If the Fuzhou Java certification training market was an era of mixed competition in the 1990s, then in the 21st century,...
rwogn Embedded System
Can someone help me? Why can't I open Mathcad15?
I have reinstalled it three times, please help me? :Cry::Cry::Cry:...
my_style RF/Wirelessly
AWR1642: Add I2C driver support to the existing mmWave SDK demo
In some special occasions, it is necessary to use AWR1642 to adjust the output voltage of PMIC or read the internal working status of PMIC. In this case, I2C interface is needed to read and write PMIC...
Jacktang Microcontroller MCU
Good book recommendation---"Microcontroller Principles and Simulation Design"
[align=center][size=5]Principles and Simulation Design of Single Chip Microcomputers[/size][/align][align=left] [/align][align=left][size=4] [/size][/align][align=left][size=4] This book is specially ...
tiankai001 Download Centre

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2341  180  27  1973  595  48  4  1  40  12 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号