EEWORLDEEWORLDEEWORLD

Part Number

Search

LTGOO505-TW-W-R/28V

Description
Rocker Switch, DPST, Latched, Wire Terminal, Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size112KB,1 Pages
ManufacturerCarling Technologies
Environmental Compliance  
Download Datasheet Parametric View All

LTGOO505-TW-W-R/28V Overview

Rocker Switch, DPST, Latched, Wire Terminal, Rocker Actuator, Panel Mount

LTGOO505-TW-W-R/28V Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator typeROCKER
body width25.24 mm
body height20.62 mm
Body length or diameter28.45 mm
Contact (AC) maximum rated R load15A@125VAC
Maximum contact current (AC)15 A
Maximum contact voltage (AC)125 V
Electrical life50000 Cycle(s)
illuminationRED LAMP
Manufacturer's serial numberLTG
Installation featuresPANEL MOUNT
Maximum operating temperature66 °C
Minimum operating temperature
surface mountNO
Switch actionLATCHED
switch functionDPST
Switch typeROCKER SWITCH
Termination typeWIRE
Base Number Matches1
Carling
Technologies
TG/LTG-Series Rocker Switches
TG/LTG-Series Rocker Switches
The TG-Series Mini Tippette rocker switches are single or
double pole and feature an all nylon double-insulated con-
struction. These switches are designed with snap-in mount-
ing for fast, low cost assembly. The illuminated version
(LTG) is available with either a paddle or rocker actuator.
These AC rated switches are also suitable for low-voltage
DC applications in a wide range of markets including
Appliance, HVAC, Food service, and Transportation.
Dielectric Strength
UL/CSA:
1000V - live to dead metal parts
Electrical Life
50,000 cycles- maintained
25,000 cycles- momentary
Mechanical Life
100,000 cycles
Operating Temperature
32°F to 150°F (0°C to +65.6°C)
.069[1.75] DIA
.156[3.96] DIA
.055[1.40] DIA
6.000[152.40]
.375[9.52]
.250[6.35]
.500[12.70]
1.155[29.33]
.865[21.97]
.050[1.27]
1.240[31.50]
.250[6.35]
.250 TAB (Q.C.)
.250[6.35]
SOLDER LUG
.187[4.74]
.187 TAB (Q.C.)
INTEGRATED WIRE LEAD
(no exposed conductors)
TERMINAL TYPE
.210[5.33]
.812[20.62]
.520[13.20]
1.125[28.57]
.375[9.52]
1.120[28.45]
PADDLE
1.000[25.40]
.994[25.24]
MOUNTING HOLE
Panel Thickness:
.030[.762] min. to
.250[6.35] max.
LTG G O 50 1
-
T B
-
B
-
R
/
125N
1
Base Part Number
2
Circuit
3
Center
Position
4
Rating
5
Termination
6
Actuator
Style
7
Actuator
Color
8
Base Color
9
Lens Color
10
Lamp
Voltage
1 BASE PART NUMBER: SERIES
1
TG
Double Pole, Non-Lighted
LTG
Double Pole with Indicator Lights
2 CIRCUIT
See Circuit Designation Chart Page 17.
3 CENTER POSITION
C
Center OFF, Three position
O
No Center OFF, Two position
4 RATING
40
5A 250VAC, 10A 125VAC, 1/2HP 125-250VAC
41
5A 250VAC, 10A 125VAC
50
10A 250VAC, 15A 125VAC, 3/4HP 125-250VAC
51
10A 250VAC, 15A 125VAC
5 TERMINATION/FUNCTION
solder lug
ON-NONE-OFF
0
(ON)-NONE-OFF
A
ON-NONE-(OFF)
L
ON-NONE-ON
0
ON-NONE-(ON)
A
ON-OFF-ON
0
6 ACTUATOR STYLE
P
paddle
7 ACTUATOR COLOR
2
B
black
8 BASE COLOR
2
B
black
9 LENS COLOR
3
A
amber
10 LAMP VOLTAGE
incandescent
6V
6 volt
12V
12 volt
18V
18 volt
24V
24 volt
28V
28 volt
wire leads
5
F
T
5
F
5
T
rocker
W
white
W
white
C
clear
R
red
neon
125N
125 volt neon
250N
250 volt neon
.250 tab QC
1
B
M
1
B
1
.187 tab QC
3
D
R
3
D
3
NOTES
Imprinting is available. Consult factory.
Panel Cut-Out Recommendations: For sheet metal panels, switch must enter panel in same direction as the punch. (Burr on bottom.) Test cut hole in actual material.
1
TG available with circuits A, B, C, D, E, F ; LTG available with circuits G, H, I, J, M, N, P, Q, R, T, U, V, Y, Z. See page 17.
2
Custom colors are available. Consult factory.
3
Specify lens color for LTG-Series only.
()
Indicates momentary function.
14
www.carlingtech.com
Improving Power Supply Network Efficiency Using Fixed Ratio Converters
Most electromechanical or semiconductor loads require stable DC-DC voltage conversion and tight regulation for reliable operation. DC-DC converters that perform this function are usually called point-...
Aguilera Analogue and Mixed Signal
Problems encountered in debugging TMS320C6416 (solutions)
I posted the following on the forum a few days ago:About the problems encountered in debugging TMS320C6416I use 6416 chips, but unfortunately the purchasing department bought the stock from 2002. I so...
queen DSP and ARM Processors
How can I tell that the gyroscope has "turned around"?
[i=s] This post was last edited by Buguojizi on 2017-10-25 14:54 [/i] I want to make a car that stops when it turns over. How can I know when the gyroscope in the car turns over? What parameters shoul...
不过机子 Sensor
Learning experience in embedded systems
[table=92%][tr][td][table=98%][tr][td][table=98%][tr][td] [/td][/tr][tr][td][/td][/tr][tr][td][align=right] [/align][/td][/tr][/table][table=98%][tr][td] [/td][/tr][/table][table=98%][tr][td][size=12p...
zjw50001 Embedded System
Proteus self-study materials
About Proteus teaching materials, OK...
781349304 MCU
Is there any expert who can help me explain the code in OSINTCTXSW() in UCOSII ported to ARM7TDMI?
AREA OSINTCTXSW,CODE,READONLY EXPORT OSIntCtxSw() add r7, sp, #16 mrs r1,SPSR orr r1, r1, #0xc0 //Turn off IRQ, FIQ msr CPSR_cxsf, r1 control field in CPSR ( PSR[7:0]) ldr r0,[r7, #52] //Get IRQ'S LR ...
wujieling Real-time operating system RTOS

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 377  2804  795  2018  1752  8  57  17  41  36 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号