The F series FMP/FMP-B has realized a thickness of 20mm max.
by the TDK original technology such as increased switching fre-
quencies and a thin-type transformer or filter. It has an equivalent
level of the FCC class B in the noise terminal voltage in spite of the
compact size. An onboard-type FMP-B is included in the lineup.
FEATURES
• AC.100V input thin-type single output power supply.
• Compact plastic package type.
• Low price.
• Low noise (FCC class B compliant).
• It is a product conforming to RoHS directive.
PPART NUMBERS AND RATINGS
FMP
Output voltage
(V)
5
12
24
3W Type
Current(A)
0.06 to 0.6
0.02 to 0.25
0.01 to 0.13
Part No.
FMP05-R60
FMP12-R25
FMP24-R13
10W Type
Current(A)
0.2 to 2
0.08 to 0.85
0.04 to 0.45
Part No.
FMP05-2R0
FMP12-R85
FMP24-R45
Conformity to RoHS Directive
FMP-B
10W Type
Output voltage 3W Type
(V)
Current(A) Part No.
Current(A) Part No.
5
0.06 to 0.6 FMP05-R60B 0.2 to 2
FMP05-2R0B
12
0.02 to 0.25 FMP12-R25B 0.08 to 0.85 FMP12-R85B
24
0.01 to 0.13 FMP24-R13B 0.04 to 0.45 FMP24-R45B
• The above products are only produced upon receipt of order. Please check a delivery date.
• Conformity to RoHS Directive: This means that, in conformity with EU Directive 2002/95/EC, lead, cadmium, mercury, hexavalent chromium, and specific
bromine-based flame retardants, PBB and PBDE, have not been used, except for exempted applications.
• All specifications are subject to change without notice.
003-01 / 20051205 / ea122_fmp.fm
(2/12)
FMP3W Type
SPECIFICATIONS AND STANDARDS
Part No.
FMP05-R60
∗
4
FMP12-R25
FMP24-R13
∗
1
5V • 0.6A
12V • 0.25A
24V • 0.13A
Rated output voltage and current
Maximum output power
W
3
3
3.1
Input conditions
Input voltage Eac
V
85 to 132[Rating: 100 to 120]
Input frequency
Hz
47 to 440[Rating: 50 to 60](Single phase)
Input current
A
0.1max./0.08typ.[AC.85V]
Surge current
A
16max.[Input and output ratings, 25°C, cold start]
Leakage current
mA
0.5max.[Input and output ratings]
Efficiency
%
68typ.
70typ.
74typ.
Output characteristics
Output voltage Edc
V
5
12
24
Voltage variable range Edc
V
4.5 to 5.5
10.8 to 13.2
21.6 to 26.4
Maximum output current
A
0.6
0.25
0.13
∗
2
Minimum output current
A
0.06
0.02
0.01
Overcurrent threshold
A
0.7 to 1.2
0.3 to 0.5
0.15 to 0.3
Source effect
%
0.1typ.[Within the input voltage range]
%
0.8typ.[10 to 100% load]
Load effect
∗
2
Total effect ±3max.(±1typ.)
Voltage
Temperature effect
%
1typ.[Ambient temperature: 0 to +50°C]
stability
Drift(Time effect)
%
1max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]
Recovery
%/ms ±4max./1max.[50 to 100% sudden load change]
Ripple Ep-p
mV
50max.
80max.
100max.
Ripple noise Ep-p
mV
100max.
150max.
150max.
Start up time
ms
100max.
Hold up time
ms
20min.
Auxiliary functions
Indicator display
No
Overvoltage protection
Uses overvoltage prevention.
∗
3
Overcurrent protection
Rectangular type, automatic recovery.
Remote ON-OFF
No
Remote sensing
No
Output voltage external variable function No
Standards
Safety standards
—
Noise terminal voltage
FCC class B meet.
Constructions
External dimensions
mm
19
×
55
×
50[H
×
W
×
L](Except input and output terminals)
Weight
g
80max.
Mounting method
Can be attached to 1 side.
Case material
Nonflammable resin.
Input and output cables
No
∗
1
Current rating(maximum output current) is determined for 0 to +50°C. Derating is required when used outside this temperature range.
∗
2
The output load variation is determined within the range set by the minimum output current and the maximum output current. Nominal values might
possibly not be satisfied when output is below the minimum output current.
∗
3
Although there is no built-in overvoltage protection circuit, the overvoltage prevention method is used for circuit design, thereby preventing overvoltage.
∗
4
Output may fail to come on when operated in series.
• All specifications are subject to change without notice.
003-01 / 20051205 / ea122_fmp.fm
(3/12)
FMP3W Type
SHAPES AND DIMENSIONS
13.5 (V.
ADJ
Position)
6.5
(11.5)
V.ADJ
+
DC OUTPUT
–
5V
0.6A
NC
6.5
7 8.5 8.5
6.5
POWER
SUPPLY
FMP05-R60
100-120V
L
50-60H
Z
0.1A
AC INPUT
N
10 (V.
ADJ
Position)
11max.
50±0.7
55±0.7
8.5
5
[Detail drawing of terminal block(187 Faston
®
tab)]
ø1.5
4.75
t=0.5
40±0.4
(5)
2-C1
3.2
(6.35)
(5)
Dimensions in mm
±0.7mm: without specified dimensions
• Do not insert M3 installation screws more than 6mm into the power supply. (Recommend torque 0.48N • m)
• Faston
®
is registered trademark of Tyco Electronics AMP Corp. incorporated.
TERMINAL DESIGNATIONS AND FUNCTIONS
V.ADJ
1
2
3
4
+
DC OUTPUT
–
5V
0.6A
NC
POWER
SUPPLY
FMP05-R60
100-120V
L
50-60H
Z
0.1A
AC INPUT
N
Terminal No.
1
2
3
4
Designations and functions
DC output terminals(+, –)
No connection (NC)
Frame ground terminal(G)
AC input terminals(L, N, AC INPUT)
Connect to load.
Connect none to this terminal.
Connected to ground lead for input line.
Connect to AC.100 to 120V single phase input line.
• All specifications are subject to change without notice.
003-01 / 20051205 / ea122_fmp.fm
45±0.4
6
5
19±0.7
2-M3 Tap
(4/12)
FMP10W Type
SPECIFICATIONS AND STANDARDS
Part No.
FMP05-2R0
∗
4
FMP12-R85
FMP24-R45
∗
1
5V • 2A
12V • 0.85A
24V • 0.45A
Rated output voltage and current
Maximum output power
W
10
10.2
10.8
Input conditions
Input voltage Eac
V
85 to 132[Rating: 100 to 120]
Input frequency
Hz
47 to 440[Rating: 50 to 60](Single phase)
Input current
A
0.35max./0.25typ.[AC.85V]
Surge current
A
16max.[Input and output ratings, 25°C, cold start]
Leakage current
mA
0.5max.[Input and output ratings]
Efficiency
%
75typ.
78typ.
81typ.
Output characteristics
Output voltage Edc
V
5
12
24
Voltage variable range Edc
V
4.5 to 5.5
10.8 to 13.2
21.6 to 26.4
Maximum output current
A
2
0.85
0.45
∗
2
Minimum output current
A
0.2
0.08
0.04
Overcurrent threshold
A
2.2 to 3.3
0.9 to 1.4
0.5 to 0.8
Source effect
%
0.1typ.[Within the input voltage range]
%
0.8typ.[10 to 100% load]
Load effect
∗
2
Total effect ±3max.(±1typ.)
Voltage
Temperature effect
%
1typ.[Ambient temperature: 0 to +50°C]
stability
Drift(Time effect)
%
1max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]
Recovery
%/ms ±4max./1max.[50 to 100% sudden load change]
Ripple Ep-p
mV
50max.
80max.
100max.
Ripple noise Ep-p
mV
100max.
150max.
150max.
Start up time
ms
100max.
Hold up time
ms
20min.
Auxiliary functions
Indicator display
No
Overvoltage protection
Uses overvoltage prevention.
∗
3
Overcurrent protection
Rectangular type, automatic recovery.
Remote ON-OFF
No
Remote sensing
No
Output voltage external variable function No
Standards
Safety standards
—
Noise terminal voltage
FCC class B meet.
Constructions
External dimensions
mm
19
×
55
×
80[H
×
W
×
L](Except input and output terminals)
Weight
g
100max.
Mounting method
Can be attached to 1 side.
Case material
Nonflammable resin.
Input and output cables
No
∗
1
Current rating(maximum output current) is determined for 0 to +50°C. Derating is required when used outside this temperature range.
∗
2
The output load variation is determined within the range set by the minimum output current and the maximum output current. Nominal values might
possibly not be satisfied when output is below the minimum output current.
∗
3
Although there is no built-in overvoltage protection circuit, the overvoltage prevention method is used for circuit design, thereby preventing overvoltage.
∗
4
Output may fail to come on when operated in series.
• All specifications are subject to change without notice.
003-01 / 20051205 / ea122_fmp.fm
(5/12)
FMP10W Type
SHAPES AND DIMENSIONS
14.5 (V.
ADJ
Position)
7 8.5 8.5 6.5 6.5 6.5 (11.5)
V.ADJ
+
DC OUTPUT
–
5V
2A
NC
POWER SUPPLY
FMP05-2R0
100-120V
L
50-60H
Z
0.35A
AC INPUT
N
10 (V.
ADJ
Position)
11max.
80±0.7
55±0.7
8.5
V.
ADJ
trimmer on opposite.
5
70±0.4
(5)
5
19±0.7
2-M3 Tap
45±0.4
[Detail drawing of terminal block(187 Faston
®
tab)]
ø1.5
4.75
t=0.5
2-C1
6
3.2
(5)
(6.35)
Dimensions in mm
±0.7mm : without specified dimensions
• Do not insert M3 installation screws more than 6mm into the power supply. (Recommend torque 0.48N • m)
• Faston
®
is registered trademark of Tyco Electronics AMP Corp. incorporated.
TERMINAL DESIGNATIONS AND FUNCTIONS
V.ADJ
1
2
3
4
+
DC OUTPUT
–
5V
2A
NC
POWER SUPPLY
FMP05-2R0
100-120V
L
50-60H
Z
0.35A
AC INPUT
N
Terminal No.
1
2
3
4
Designations and functions
DC output terminals(+, –)
No connection (NC)
Frame ground terminal(G)
AC input terminals(L, N, AC INPUT)
Connect to load.
Connect none to this terminal.
Connected to ground lead for input line.
Connect to AC.100 to 120V single phase input line.
• All specifications are subject to change without notice.