312035P

Description
FAST BLOW ELECTRIC FUSE, 35A, 32VAC, INLINE/HOLDER
CategoryCircuit protection    Circuit protection   
File Size39KB,1 Pages
ManufacturerLittelfuse
Websitehttp://www.littelfuse.com
Environmental Compliance
Download Datasheet Parametric View All

312035P Overview

FAST BLOW ELECTRIC FUSE, 35A, 32VAC, INLINE/HOLDER

312035P Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerLittelfuse
package instructionROHS COMPLIANT
Reach Compliance Codeunknown
Fusing characteristicsFAST
body height31.75 mm
Body length or diameter6.35 mm
Circuit protection typeELECTRIC FUSE
Joule integral nominal7531 J
Manufacturer's serial number312P
Installation featuresINLINE/HOLDER
physical size6.35mm x 31.75mm
Rated current35 A
Rated voltage (AC)32 V
GuidelineCE
surface mountNO
Terminal surfaceNickel (Ni)
Terminal shapeEND CAP
Base Number Matches1
Axial Lead and Cartridge Fuses
Glass Body
RoHS
Pb
3AG
Fast-Acting Type 312P/318P Series
UL
®
®
A standard for cost-effective reliability and performance in circuit protec-
tion, the 3AG fuse satisfies a broad range of application requirements.
ELECTRICAL CHARACTERISTICS:
% of Ampere
Rating
100%
135%
200%
Ampere
Rating
1/32–35
1/32–35
1/32–10
12–30
35
Opening
Time
4 hours,
Minimum
1 hour,
Maximum
5 sec.,
Maximum
10 sec.,
Maximum
20 sec.,
Maximum
AGENCY APPROVALS:
Listed by Underwriters Laboratories and
Certified by CSA through 30 amperes.
1/100–10 amperes listed to UL 248-14 (UL 198-G)
12–30 amperes listed to UL 275.
AGENCY FILE NUMBERS:
UL E10480, CSA LR 29862.
312
000P
Series
6.985 (.275")
6.35
(.25")
31.75
(1.25")
318
000P
Series
0.813
(.032")
INTERUPTING RATING:
10,000A @ 125VAC
35A @ 250VAC
ORDERING INFORMATION:
Cartridge
Catalog
Number
312.031P
312.062P
312.100P
312.125P
312.150P
312.175P
312.187P
312.200P
312.250P
312.300P
312.375P
312.500P
312.600P
312.750P
312
001P
312
1.25P
312
01.5P
312
01.6P
312
1.75P
312
01.8P
312
002P
312
2.25P
312
02.5P
312
003P
312
004P
312
005P
312
006P
312
007P
312
008P
312
010P
312
012P
312
015P
312
020P
312
025P
312
030P
312
035P
Axial Lead
Catalog
Number
318.031P
318.062P
318.100P
318.125P
318.150P
318.175P
318.187P
318.200P
318.250P
318.300P
318.375P
318.500P
318.600P
318.750P
318
001P
318
1.25P
318
01.5P
318
01.6P
318
1.75P
318
01.8P
318
002P
318
2.25P
318
02.5P
318
003P
318
004P
318
005P
318
006P
318
007P
318
008P
318
010P
Nominal
Resistance
Cold Ohms
23.3
24.5
11.2
7.10
5.10
3.85
3.40
3.00
2.00
1.40
0.820
0.495
0.360
0.243
0.189
0.138
0.103
0.0930
0.0850
0.0820
0.0700
0.0590
0.0510
0.0424
0.0291
0.0223
0.0177
0.0145
0.0121
0.00925
0.0071
0.0052
0.0034
0.0024
0.0019
0.0013
Nominal
Melting I
2
t
A
2
Sec.
0.0000300
0.000249
0.00102
0.00289
0.00550
0.00960
0.0128
0.0165
0.0355
0.0689
0.185
0.483
0.880
1.84
0.760
1.45
2.35
2.80
3.60
3.85
5.20
7.20
9.54
14.0
28.5
50.0
81.1
118.0
166.0
298.0
38.1
(1.50") TYP.
Axial Lead Material: Tin coated copper.
32.385
(1.275")
Ampere
Rating
1/32
1/16
1/10
1/8
15/100
.175
3/16
2/10
1/4
3/10
3/8
1/2
6/10
3/4
1
1
1
/
4
1
1
/
2
1
6
/
10
1
3
/
4
1
8
/
10
2
2
1
/
4
2
1
/
2
3
4
5
6
7
8
10
12
15
20
25
30
35
Voltage
Rating
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
32
32
32
32
32
32
Average Time Current Curves
.031 A
.062 A
.125 A
1000
100
TIME IN SECONDS
10
1
0.1
0.01
0.005 0.01
.250 A
.375 A
.500 A
.750 A
1A
1.5 A
2A
2.5 A
3A
4A
5A
6A
7A
8A
10 A
1
0.1
CURRENT IN AMPERES
10
100
402
w w w. l i t t e l f u s e . c o m
Application of Embedded Linux in CNC System
First, the concept and characteristics of embedded systems are introduced, and then the application of embedded Linux in CNC systems is discussed. The paper focuses on system modeling and real-time so...
frozenviolet Linux and Android
Selecting the right inductor for a switching power supply
[p=30, null, left][font=宋体][color=#000000] [size=3]Inductors are commonly used components in switching power supplies. Since their current and voltage phases are different, theoretically, their losses...
fish001 Energy Infrastructure?
[Learning experience power supply] TI battery power monitoring basics chapter 1 concept
TI battery capacity monitoring basics, in the first chapter, first introduced to us, the basics of battery capacity monitoring, respectively, talked about: What is battery capacity measurement technol...
Sur Analogue and Mixed Signal
Please ask the moderator for I2C questions
void I2C_ADS1110_Init(void){GPIO_InitTypeDef GPIO_InitStructure;I2C_InitTypeDef I2C_InitStructure; /* GPIOB Periph clock enable */RCC_APB2PeriphClockCmd(RCC_APB2Periph_AFIO |RCC_APB2Periph_GPIOB, ENAB...
friend stm32/stm8
How to select all device bit numbers or nominal values in the SCH file for AD1904 version
How to select all the device bit numbers or nominal values in the SCH file for AD1904 versionCan only one device be modified at a time? Waiting online... . . . . . . . . . . . . ....
btty038 PCB Design
EEWORLD University Hall----SIMPLE SWITCHER Easy Power Nano Module and Regulator plus TI Processor
SIMPLE SWITCHER Easy Power Nano Module and Regulator plus TI Processor : https://training.eeworld.com.cn/course/142...
zhangjianee Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1925  2881  454  1883  544  39  58  10  38  11 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号