EEWORLDEEWORLDEEWORLD

Part Number

Search

LWN2320-6EM2FK2G

Description
DC-DC Regulated Power Supply Module, ROHS COMPLIANT
CategoryPower/power management    The power supply circuit   
File Size1MB,28 Pages
ManufacturerBel Fuse
Download Datasheet Parametric View All

LWN2320-6EM2FK2G Overview

DC-DC Regulated Power Supply Module, ROHS COMPLIANT

LWN2320-6EM2FK2G Parametric

Parameter NameAttribute value
package instruction,
Reach Compliance Codeunknown
Analog Integrated Circuits - Other TypesDC-DC REGULATED POWER SUPPLY MODULE
JESD-30 codeR-XXMA-X
Package body materialUNSPECIFIED
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Certification statusNot Qualified
surface mountNO
Terminal formUNSPECIFIED
Terminal locationUNSPECIFIED
Base Number Matches1
®
W Series Data Sheet
125, 250 Watt AC-DC and DC-DC DIN-Rail Converters
Features
• RoHS lead-free-solder and lead-solder-exempted
products are available
• Rugged 35 mm DIN-rail snap-fit design
• Class I equipment
• Universal AC-input with single stage conversion AC to
DC, or DC input of 66 to 350 V
• Power factor correction, harmonics IEC/EN 61000-3-2
• Virtually no inrush current
• Immunity to IEC/EN 61000-4-2, -3, -4, -5, -6, -11
• Emissions according to EN 55011/022
• Very high efficiency; up to 89%
• Short-term output peak power capability, rectangular
current limiting characteristic
• Single or two independently regulated outputs with 12,
24, 36, or 48 V
• Outputs no-load, overload, and short-circuit proof
• PCBs protected by lacquer
• Very high reliability
138
5.43"
Safety according to IEC/EN 60950-1, UL/CSA 60950-1,
IEC/EN 50178, IEC 61010-1, UL 508
103
4.05"
114
4.49"
Description
The Convert Select front end series represents a family of
DIN-rail mountable DC-DC and AC-DC converters with power
factor correction. The converters have been designed
according to the latest industry requirements and standards.
The converters are ideal for use in outdoor and other
demanding applications to power building control systems,
factory automation, industrial controls, instrumentation,
electromagnetic drives, fans, and other DC loads. Different
models are available with a single output or two
independently regulated, electrically isolated outputs with 12,
24, 36, or 48 V. Special models for battery charging are
available. The EW models are particularly suitable for 110 V
railway applications; they have been designed in accordance
with the railway standards EN 50155 and EN 50121.
Key features of the Convert Select line include power factor
correction with low harmonic distortion, negligibly low inrush
current, high immunity to transients and surges, and low
electromagnetic emissions. Internal protection circuits such as
input over- and undervoltage lockout, thermal protection, as
well as output overvoltage protection by a second control loop
ensure safe operation of the final system.
The outputs deliver an electrically-isolated Safety Extra Low
Voltage, SELV, (except models LWR/LWN1740) and low output
noise. They are no-load, overload, and short-circuit proof. The
electronically controlled short-term peak power capability of up
to 150% of the rated output power enables the front end
converters to deliver additional power to start-up motors or to
safely operate subsequent circuit breakers. Built-in large sized
output capacitors absorb possible reverse energy, which may
be caused by quick deceleration of electromagnetic drives
connected directly to the output. A green LED at the front cover
displays the status of the output(s).
The Convert Select Series was designed according to all
relevant international safety standards. The converters are
approved by TÜV and UL, and are UL 508 listed. Adequate
Table of Contents
Page
Page
Immunity to Environmental Conditions ................................. 16
Mechanical Data ................................................................... 17
Safety and Installation Instruction ......................................... 18
Description of Options .......................................................... 21
Accessories ........................................................................... 24
EC Declarations of Conformity ............................................. 26
www.power-one.com
Description .......................................................................... 1
Model Selection .................................................................. 2
Functional Description ........................................................ 4
Electrical Input Data ............................................................ 6
Electrical Output Data ......................................................... 8
Electromagnetic Compatibility (EMC) ............................... 13
BCD20020-G REV AA
Page 1 of 28
A 51 MCU with 4K memory is only 2.8 yuan?!!!
51 MCU with 4K memory is only sold for 2.8 yuan?!!! Hunan Huaxin Company just started to make 51 chips. Is it because of the early development and investment costs that only one mold of the two chips ...
songbo 51mcu
IC Purchasing Guide: How to Identify Counterfeit and Refurbished ICs
Be careful when buying chips! Generally, if you buy more than 30 or 50 chips, it is best to find an agent or its distributor instead of going to a general "general goods" counter to get the goods. Gen...
bolibo123 Buy&Sell
How to estimate the delay time
As the title suggests, make a delayed start button circuit as follows:...
simonprince Analog electronics
The 72 yuan Ferroelectric MSP-EXP430FR5739 is very attractive
An MSP430 debugger costs $150!An official development board of Ferroelectric MSP-EXP430FR5739 is only 72!The key is the FR5739 ferroelectric memory , which is absolutely cheap.The MSP-EXP430FR5739 has...
wstt Microcontroller MCU
Bounty Survey: What kind of products with embedded MCUs require floating-point calculations?
I remember that many people asked about floating point calculations before. I am very curious about what kind of applications need floating point calculations? What is the required performance? I hope...
icu stm32/stm8
How to mark the voltage reference direction of the components in a circuit with two voltage sources, as shown in the figure
[p=20, null, left][color=#333333][font=arial, 宋体, sans-serif, tahoma,]How do you mark the voltage reference direction of components in a circuit with two voltage sources? Try marking the reference dir...
六耳先生 Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2177  2171  839  1160  197  44  17  24  4  28 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号