FMTP-20-D-03.85-01

Description
Interconnection Device, ROHS COMPLIANT
CategoryThe connector    The connector   
File Size867KB,1 Pages
ManufacturerSAMTEC
Websitehttp://www.samtec.com/
Environmental Compliance  
Download Datasheet Parametric View All

FMTP-20-D-03.85-01 Overview

Interconnection Device, ROHS COMPLIANT

FMTP-20-D-03.85-01 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
Factory Lead Time2 weeks
Connector typeINTERCONNECTION DEVICE
Base Number Matches1
F-214
FMTP–10–D–03.85–01
•••••••••••••••••••
(1,27 mm) .050"
FFTP–20–D–08.77–01–N
FFTP, FMTP SERIES
TIGER EYE TWISTED PAIR IDC CABLES
FFTP Mates with:
FTS, FTSH, EHF, SHF
FMTP Mates with:
FLE*, SFMC*
FFTP
PINS
PER ROW
END
ASSEMBLY
ASSEMBLY
LENGTH
01
N
OPTION
SPECIFICATIONS
For complete specifications
see www.samtec.com?FFTP
or www.samtec.com?FMTP
Insulator Material:
PBT
Contact (FFTP):
BeCu
Terminal (FMTP):
Phosphor Bronze
Plating (FFTP):
10µ" (0,25 µm)
Au over 50µ" (1,27 µm)
Ni on contact area; Sn over
50µ" (1,27 µm) Ni on balance
Plating (FMTP):
Sn over 50µ" (1,27 µm) Ni
Wire:
30 AWG 7/38,
Tinned, Twisted Pair
with PVC insulator
Operating Temp Range:
-40°C to +105°C
Lead Size Accepted:
(0,41 mm) .016" SQ
Contact Resistance:
15 mΩ
Insertion Depth (FFTP):
(2,64 mm) .104" to
(3,17 mm) .125"
Insertion Force (FFTP):
(Single contact only)
5 oz (1,39 N) avg.
Withdrawal Force (FFTP):
(Single contact only)
3 oz (0,83 N) avg.
RoHS Compliant:
Yes
–D
–05, –08, –10, –13,
–17, –20, –25
(Standard sizes)
ASSEMBLY LENGTH
= Double
End
–03.85
= (97,79 mm) 3.85"
–N
= Notch
Polarization
(Standard)
–R
= Reverse
Connector
–08.77
= (222,76 mm) 8.77"
(1,90)
.075
–18.00
No. of
positions
x
(1,27)
.050
+
(4,19)
.165
= (457,20 mm) 18.00"
(Standard Lengths)
–R
FFTP
(1,02) .040
(3,05)
.120
Cable
Length
3.85" (97,8 mm)
(5,08)
.200
Rated @ 7dB Insertion Loss
–SE
–D
2.0 GHz / 4.00 Gbps
Performance data for other cable lengths and complete test data
available at www.samtec.com?FFTP or contact sig@samtec.com
FMTP
PINS
PER ROW
END
ASSEMBLY
ASSEMBLY
LENGTH
01
TRANSFER
OPTION
OPTION
RECOGNITIONS
For complete scope of
recognitions see
www.samtec.com/quality
–D
–05, –08, –10,
–13, –17, –20, –25
(Standard sizes)
ASSEMBLY LENGTH
No. of
positions
x
(1,27)
.050
+
(4,19)
.165
–03.85
= (97,79 mm)
3.85"
–R
Leave blank for
–D End Assembly.
For –T End Assembly
Specify “–N”
(Socket has notch
polarization)
= Reverse
Connector
= Double End
–T
= Transfer End
–08.77
= (222,76 mm)
8.77"
ALSO AVAILABLE
(MOQ Required)
• Other sizes
• Other cable lengths
Contact Samtec.
*Note:
Standard FMTP callout
will not mate with FLE, SFMC.
Must use gold plated callouts.
(See drawing on web.)
When mated with a socket,
Wire 1 mates with Pin 2;
Wire 2 mates wth Pin 1, etc.
Note:
This Series is
non-standard, non-returnable.
–18.00
= (457,20 mm)
18.00"
(Standard
Lengths)
(3,05)
.120
(5,08)
.200
–R
(1,27)
.050
(3,07)
.121
–D
(0,41) .016 SQ
–T
WWW.SAMTEC.COM
EEWORLD University ---- Power Supply Design Tips 2
Power Design Tips 2 : https://training.eeworld.com.cn/course/503...
dongcuipin Power technology
Internal and external structure of single chip microcomputer (I)
Internal and external structure of single chip microcomputer (I)1. External structure of single chip microcomputerIf you want to use a chip, you must first know how to connect it. We use a chip called...
rain MCU
Is there any official routine for developing EFM8 in Simplicity Studio? Where can I download it?
Is there any official routine for developing EFM8 in Simplicity Studio? Where can I download it?...
新手拉 RF/Wirelessly
Several questions about ARM
I have a question, brother. I have finished learning MCU and am learning ARM7. I have encountered a problem. I am a student. If anyone has ARM embedded teaching courseware from Inbit, please give me o...
liwei3290 ARM Technology
Rapidly develop monitoring systems for grid-connected photovoltaic (PV) equipment using LabVIEW software and NI PXI hardware
Time: 2010-07-13 11:14:11 Source: National Instruments (NI) Author:Challenge: Build a customized real-time monitoring system in a short time and at a low cost, capable of evaluating the performance an...
安_然 Energy Infrastructure?
CE6.0 cannot run after loading. The serial port output is as follows. It seems that there is a problem with the display driver or hard disk power supply.
I have been working on this for several days. I am about to collapse. I boot the computer with DOS, loadcepc to load nk.bin. Atom z530, chipset US15W. After loading the kernel, the screen shows Jumpin...
王增 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 573  1879  2537  36  1175  12  38  52  1  24 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号