UBJ49-27

Description
PANEL MOUNT, CABLE TERMINATED, FEMALE, TNC CONNECTOR, CRIMP, JACK
CategoryThe connector    The connector   
File Size69KB,1 Pages
ManufacturerVertiv
Download Datasheet Parametric View All

UBJ49-27 Overview

PANEL MOUNT, CABLE TERMINATED, FEMALE, TNC CONNECTOR, CRIMP, JACK

UBJ49-27 Parametric

Parameter NameAttribute value
Reach Compliance Codeunknown
ECCN codeEAR99
Body/casing typeJACK
Characteristic impedance75 Ω
Connector typeRF TNC CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderFEMALE
Contact materialNOT SPECIFIED
Coupling typeTHREADED
DIN complianceNO
Filter functionNO
IEC complianceNO
insulator materialPOLYTETRAFLUORO ETHYLENE
MIL complianceNO
Manufacturer's serial number40
Installation methodSTRAIGHT
Installation typeCABLE
Maximum operating frequency11 GHz
OptionsGENERAL PURPOSE
Panel mountingYES
Termination typeCRIMP
voltage standing wave ratio1.3
Base Number Matches1
29
Miniature coax threaded
40/240 series, tnc bulkhead jacks
BJ41 Shown
BJ40 Shown
1.060
.757
SOLDER POT ACCEPTS
.060 DIA CONDUCTOR
.380
DIA
.382
.378
DIA
.375-32UNEF-2A
1.058
.425
.046
Bulkhead Jack
SOLDER POT ACCEPTS
.060 DIA CONDUCTOR
Solder Pot
.4375-28UNEF-2A
.500-28UNEF-2A
.562 HEX NUT
.562 HEX NUT
Insulated
Bulkhead Jack
.4375-28UNEF-2A
.500 HEX NUT
BJ40
50Ω
75Ω
UBJ40
w/ Solder Lug
BJ40SL
50Ω
75Ω
UBJ40SL
Mounting Hole:
D5.125
Rear Mount, Solder Pot
BJ41
50Ω
75Ω
UBJ41
Mounting Hole:
D3.147
BJ47 Shown
1.060
.471
BJ46-1 Shown
1.000
.830
.790
.096
SOLDER POT
ACCEPTS
.060 DIA
CONDUCTOR
Insulated
Bulkhead Jack
Insulated
Bulkhead Jack
Front Mount, Solder pot
Mounting Hole:
D3.147
BJ49-1 Shown
1.000
.806
.500-28UNEF-2A
.562 HEX NUT
50Ω
.562 HEX NUT
75Ω
BJ47
UBJ47
.437 HEX
.687 HEX
.625-24UNEF-2A
.750 HEX NUT
.4375-28UNEF-2A
Rear Mount, Wrench Crimp
50Ω
BJ46-
1
75Ω
UBJ46-
1
Mounting Hole:
D2.187
GF
-Ground filter version page 31.
.096
.437 HEX
1.626
1.000
.790
.437 HEX
.830
DIA
MAX
BJ246-001 Shown
Bulkhead
Cable Jack
.687 HEX
.500-28UNEF-2A
50Ω
.625 HEX
.4375-28UNEF-2A
Wrench Crimp
75Ω
Mounting Hole:
D3.218 / D2.218 (Cable Groups 6, 6E,51,52)
BJ49-
UBJ49-
1
1
Insulated
Bulkhead Jack
Rear Mount, Tool Crimp
BJ246-
1
50Ω
75Ω
UBJ246-
1
Mounting Hole:
D2.187
GF
-Ground filter version pg 31.
1.000
.806
1.625
.437 HEX
.750 HEX NUT
.4375-28UNEF-2A
.750
DIA
Bulkhead
Cable Jack
Tool Crimp
MODEL
LTR
NO.
CODE
CBBJR46
-
UCBBJR46
-
CBBJR46A
A
UCBBJR46A
A
OHM
50
75
50
75
A
DIM
.046
.029
.046
.029
B
DIM
.24
.24
.34
.34
C
DIM
.090
.090
.090
.090
D
DIM
.050
.050
.058
.058
E
DIM
.0625
.0625
.070
.070
CBBJR46 Shown
.625 HEX NUT
.4375-28UNEF-2A
BJ249-
1
50Ω
Mounting Hole:
D3.218
D2.218 (Cable Groups 6,6E,51,52)
E DIA
TYP
.258
TYP
1.237
1.074
.773
.046
.593 DIA
.649
ACROSS
POINTS
MODEL
LTR OHM A
B
C
D
E
NO.
CODE
DIM DIM DIM DIM DIM
CBBJR49
-
50 .046 .24 .090 .050 .0625
UCBBJR49
-
75 .029 .24 .090 .050 .0625
CBBJR49A
A
50 .046 .34 .090 .058 .070
UCBBJR49A
A
75 .029 .34 .090 .058 .070
1.237
1.074
.380
DIA
.773
.046
.593 DIA
.258
.380
DIA
.030
TYP
.4375-28UNEF-2A
.500-28UNEF-2A
.562 HEX NUT
.258
TYP
.124
D
TYP
.258
TYP
C
TYP
B
TYP
A DIA
.649
ACROSS
POINTS
B
.13 TYP
.030
TYP
.4375-28UNEF-2A
E DIA TYP
.040
TYP
.258
TYP
.500-28UNEF-2A
.124
.562 HEX NUT
.258
TYP
.13 TYP
.258
D
C
A DIA
Insulated Circuit Board Jack
Right Angle
"A" refers to tall versions
1
50Ω
CBBJR46
75Ω
UCBBJR46
50Ω
CBBJR46A
75Ω
UCBBJR46A
Mounting Hole:
D3.156
CBBJR49 SHOWN
.040
TYP
.258
TYP
Circuit Board Jack
Bulkhead mount
Right Angle
Add "A" for tall versions
50Ω
CBBJR49
75Ω
UCBBJR49
Mounting Hole:
D3.230
- Refers to Cable Group Table, see pages 68-88. "D" mounting holes are on page 45.
Trompeter Products Catalog
ISO 9001
Registered
R
(800) 982-2629
Fax: (818) 706-1040
Migrating between TMS320F28004x and TMS320F28002x
This migration guide describes the hardware and software differences to be aware of when migrating between the F28004x and F28002x C2000 MCUs. This document provides block diagrams of the two MCUs to ...
fish001 Microcontroller MCU
The influence of electrical noise on control system
When a control system is exposed to high levels of electronic noise, its reliability will be reduced, but this effect can be minimized by using proper power and grounding methods. Various components i...
songrisi Industrial Control Electronics
K210 performance test again
使用Loboris的K210版本,进行了一次计算性能测试,供大家参考。[table] [tr=rgb(230, 230, 230)][td] [/td][td][b]MCU[/b][/td][td][align=left][b]Freq[/b][/align][/td][td][align=center][b]Int Add[/b][/align][/td][td][align=center][b...
dcexpert MicroPython Open Source section
How to disable the touch screen of wince5.0?
Just as the title says, thank you!...
wfiu Embedded System
[Play with C2000 Launchpad] Novice LESSON3-Understanding C Programs
A novice learner of C2000 LESSON3: Understanding C Programs. Preface: It is just about understanding C programs, not including the understanding of GPIO registers. I have not yet begun to understand t...
常见泽1 Microcontroller MCU
Why is there a problem with this two-machine communication?
The host sends data to the slave every 200ms. After receiving the data, if the slave determines that there is no error in the data reception, it returns the data to the host to light up the host's LED...
thingwind Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 349  623  1528  581  2114  8  13  31  12  43 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号