BK/GDC-2.5AV

Description
Electric Fuse, Time Delay Blow, 2.5A, 250VAC, 35A (IR), Through Hole
CategoryCircuit protection    Circuit protection   
File Size323KB,2 Pages
ManufacturerCooper Industries
Download Datasheet Parametric View All

BK/GDC-2.5AV Overview

Electric Fuse, Time Delay Blow, 2.5A, 250VAC, 35A (IR), Through Hole

BK/GDC-2.5AV Parametric

Parameter NameAttribute value
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
Reach Compliance Codeunknown
ECCN codeEAR99
Fusing characteristicsTIME DELAY
body height21.1 mm
Body length or diameter5.54 mm
Circuit protection typeELECTRIC FUSE
JESD-609 codee3
Joule integral nominal59 J
Manufacturer's serial numberGDC
Installation featuresTHROUGH HOLE
method of packingBOX
physical size5.54mm x 21.1mm
Rated breaking capacity35 A
Rated current2.5 A
Rated voltage (AC)250 V
GuidelineIMQ; MITI/JET; UL
surface mountNO
Terminal surfaceTin (Sn)
Terminal shapePIN WIRE
Base Number Matches1
5 x 20mm Fuses
GDC Series, Time-Delay, Glass Tube
Description
• Time-delay, low breaking capacity
• Optional axial leads available
• 5 x 20mm physical size
• Glass tube, nickel-plated brass endcap construction
• Designed to IEC 60127-2 (32mA-10A)
Electrical Characteristics
2.1 In
2.75 In
4 In
In
max
min
max
min
max
32mA-100mA 2 min 200 ms 10 sec 40 ms 3 sec
125mA-6.3A 2 min 600 ms 10 sec 150 ms 3 sec
10 In
min
max
10 ms 300 ms
20 ms 300 ms
Agency Information
• cURus Recognition: Guide JDYX2/JDYX8, File E19180
• IMQ Approval: File E1921, CA03.00530
• MITI/JET: File JET1641-31003-1005
Ordering
• Specify packaging, product, and option code
• With TR2 packaging code, lead wire length is 19.05mm
Dimensions - mm
Drawing Not to Scale
Specifications
Voltage Interrupting Rating (amps)
Typical DC
Product Code Rating
at Rated Voltage (50Hz) Cold Resistance
Vac
Vac
(Ω)*
GDC-32mA
250
35
21.0
GDC-40mA
250
35
13.90
GDC-50mA
250
35
9.24
GDC-63mA
250
35
6.96
GDC-80mA
250
35
4.42
GDC-100mA
250
35
2.80
GDC-125mA
250
35
1.97
GDC-160mA
250
35
1.27
GDC-200mA
250
35
1.00
GDC-250mA
250
35
0.640
GDC-315mA
250
35
0.450
GDC-400mA
250
35
0.31
GDC-500mA
250
35
0.183
GDC-630mA
250
35
0.186
GDC-800mA
250
35
0.129
GDC-1A
250
35
0.0757
GDC-1.25A
250
35
0.060
GDC-1.6A
250
35
0.0425
GDC-2A
250
35
0.03325
GDC-2.5A
250
35
0.0255
GDC-3.15A
250
35
0.0185
GDC-4A
250
40
0.0139
GDC-5A
250
50
0.00985
GDC-6.3A
250
63
0.0071
* DC Cold Resistance (measured at <10% of rated current)
‡ Typical Voltage Drop (voltage drop was measured at 20°C ambient temperature at rated current)
Typical
Melting I
2
t
(amps)
0.0051
0.0072
0.0095
0.021
0.038
0.045
0.063
0.093
0.114
0.265
0.621
0.872
0.827
1.33
2.78
6.45
10.05
21.7
31.6
59.4
96.4
71.8
142.5
237.6
Typical
Agency Approvals
Voltage
Drop (mV)‡ cURus IMQ MITI/JET
1050
X
X
920
X
X
800
X
X
760
X
X
580
X
X
490
X
X
390
X
X
320
X
X
340
X
X
270
X
X
250
X
X
210
X
X
140
X
X
150
X
X
75
X
X
87.5
X
X
X
86
X
X
X
82
X
X
X
77
X
X
X
72.5
X
X
X
68.5
X
X
X
67
X
X
X
60.5
X
X
X
54
X
X
X
0209 BU-SB08382
Page 1 of 2
Data Sheet 2016
How to change the three-phase transformer from Y/Y-12 connection group to Y/Y-6 connection group and from Y/ -11 to Y/ -5 connection group
I would like to ask how to change the [/size][/font][size=10.5pt]Y/Y[/size][font=宋体][size=10.5pt]-[/size][/font][size=10.5pt]12[/size][font=宋体][size=10.5pt] connection group to [/size][/font][size=10....
lnx Power technology
Digital System Design Tutorial
Take a good look...
qbknight DSP and ARM Processors
Design of Control Inductor in Magnetic Amplifier Voltage Stabilizer
Design of Control Inductor in Magnetic Amplifier Voltage Stabilizer Abstract: The working principle of the magnetic amplifier voltage regulator is introduced, the design method of the control inductor...
zbz0529 Industrial Control Electronics
Why does GetMessage not get any message?
I created a thread while(g_flag) { result = GetMessage(&Message, 0, 0, 0); if(result == 1) { if(Message.message == WM_TIMER) { count ++; } if(Message.message == WM_LBUTTONDOWN) { count = 0; } Translat...
54413141 Embedded System
EEWORLD University Hall----Circuit (Jiangsu University)
Circuits (Jiangsu University) : https://training.eeworld.com.cn/course/2728701 Circuits and circuit models02Reference directions of current and voltage03Electric power and energy04Resistor05Voltage so...
JFET Analog electronics
【Show Classics】Home Appliances - Table Lamp
[i=s]This post was last edited by dontium on 2015-1-23 13:23[/i]1. USB desk lamp The circuit diagram of the USB desk lamp is shown below. To avoid possible electromagnetic radiation, the power supply ...
常见泽1 Analogue and Mixed Signal

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2557  1970  1915  621  1218  52  40  39  13  25 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号