EEWORLDEEWORLDEEWORLD

Part Number

Search

56.44.9.012.2046

Description
Electromechanical Relay, 4PDT, 13.2VDC (Coil), 1.3W@12VDCmW (Coil), Random, AC/DC Output
CategoryMechanical and electronic products    relay   
File Size2MB,10 Pages
ManufacturerFINDER
Download Datasheet Parametric View All

56.44.9.012.2046 Overview

Electromechanical Relay, 4PDT, 13.2VDC (Coil), 1.3W@12VDCmW (Coil), Random, AC/DC Output

56.44.9.012.2046 Parametric

Parameter NameAttribute value
Reach Compliance Codecompli
body width27.7 mm
body height37.1 mm
Body length or diameter40.8 mm
Coil operating voltage (DC)10.2 V
Coil power1300 mW
Coil resistance123 Ω
Maximum coil voltage (DC)13.2 V
Nominal coil voltage12 V
Coil/Input Power TypeDC
Contact (AC) maximum rated R load20A@400VAC
Maximum contact current (AC)20 A
Maximum contact voltage (AC)400 V
Contact/Output Power TypeAC/DC
Dielectric strength between coil and contacts5000 Vrms
Dielectric strength between breaking contacts1000 Vrms
Electrical life100000 Cycle(s)
End contact materialSilver Cadmium Oxide
Input switching control typeRandom
Number of terminals14
operating hours10 ms
PCB hole count14
physical size40.8mm x 27.7mm x 37.1mm
GuidelineCSA; IMQ; PCT; UL; VDE
Relay function4PDT
release time4 ms
Terminal length0.0043 inch
Termination typeSOLDER
Base Number Matches1
56
56 Series - Miniature power relays 12 A
Features
Plug-in - 12 A Power relay, 2 & 4 pole
Flange mount option -
(Faston 187, 4.8x0.5 mm termination)
AC coils & DC coils
Lockable test button and mechanical flag indicator
Cadmium Free contacts (standard version)
Contact material options
96 series sockets
Coil EMC suppression
Accessories
European Patent
SERIES
56.32/56.34
56.32-0300
Plug-in / PCB Relays
1
2 or 4 pole changeover contact
Plug-in/Faston 187
2 pole normally open contact
(≥1.5 mm gap)
Plug-in/Faston 187
56.32
56.32-0300
56.34
* For 4 CO (4PDT) only.
F
OR
UL
RATINGS SEE
:
“General technical information” page
V
Contact specification
Contact configuration
Rated current/Maximum peak current
Rated load AC1
Rated load AC15 (230 V AC)
Single phase motor rating (230 V AC)
Breaking capacity DC1: 30/110/220 V
Minimum switching load
Standard contact material
Coil specification
Nominal voltage (U
N
)
Rated power AC/DC
Operating range
Holding voltage
Must drop-out voltage
Technical data
Mechanical life AC/DC
Electrical life at rated load AC1
Operate/release time
XI-2013, www.findernet.com
56.32
56.34
56.32-0300
2 CO (DPDT)
A
VA
VA
kW
A
12/20
250/400
3,000
700
0.55
4 CO (4PDT)
2NO (DPST-NO) -
≥1.5mm
gap
12/20
250/400
3,000
700
0.55
12/1/0.5
500 (10/5)
AgNi
Rated voltage/Maximum switching voltage V AC
12/0.5/0.25
500 (10/5)
AgNi
mW (V/mA)
V AC (50/60 Hz)
V DC
VA (50 Hz)/W
AC
DC
AC/DC
AC/DC
cycles
cycles
ms
V AC
°C
8/3
4
1.5/1
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400*
6 - 12 - 24 - 48 - 60 - 110 - 125 - 220
2/1.3
(0.8…1.1)U
N
(0.8…1.1)U
N
(0.85…1.1)U
N
0.8 U
N
/0.6 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
100 · 10
3
10/4
5
1,000
–40…+70
RT I
1.5/—
(0.85…1.1)U
N
0.85 U
N
/—
0.2 U
N
/—
20 · 10
6
/—
100 · 10
3
8/4
4
2,000
–40…+70
RT I
Insulation between coil and contacts (1.2/50 µs) kV
Dielectric strength between open contacts
Ambient temperature range
Environmental protection
Approvals
(according to type)
SAMR21 Serial Communication
[align=center]SAMR21[font=宋体]Serial Communication[/font][/align][align=left]The concept of serial communication is very simple. The serial port sends and receives bytes by bit. Although slower than pa...
574433742 Microchip MCU
TI Packet Sniffer 2.15.2 packet capture failed
I don't know what other parameters need to be set for the coordinator and router to communicate. Data exchange is going on but packet capture always fails. The channel is 2480. I have tried all three ...
高兴就好 RF/Wirelessly
About Workbench 2.6
Dear experts, do you have any documents like the user manual of worksbench2.6 that you can share? If it is in Chinese, it would be even better. Thank you!...
wzqd2001 Embedded System
Improve LCD backlight dimming granularity(1)
With a 31-step dimming range, existing LED drivers offer good dimming capabilities, providing smooth backlight boost or dimming effects for LCD displays. However, such a range may not be enough when t...
songbo Analog electronics
Test zero switching
I would like to ask all the experts how to use an oscilloscope to measure the zero switching point of AC Source and relay. Can you tell me in detail? Thank you....
apl500 Test/Measurement
What are the ways to communicate between microcontrollers?
I am currently using the communication between the 51 series microcontroller and the PIC series microcontroller. I hope you guys can tell me about it. Thank you very much!...
jgj Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 48  2593  779  1995  1658  1  53  16  41  34 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号