EEWORLDEEWORLDEEWORLD

Part Number

Search

BK2320-7RVTBG

Description
DC-DC Regulated Power Supply Module, 2 Output, 150W, Hybrid, ROHS COMPLIANT PACKAGE-11
CategoryPower/power management    The power supply circuit   
File Size1MB,31 Pages
ManufacturerBel Fuse
Environmental Compliance
Download Datasheet Parametric View All

BK2320-7RVTBG Overview

DC-DC Regulated Power Supply Module, 2 Output, 150W, Hybrid, ROHS COMPLIANT PACKAGE-11

BK2320-7RVTBG Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
package instruction,
Reach Compliance Codecompliant
ECCN codeEAR99
Analog Integrated Circuits - Other TypesDC-DC REGULATED POWER SUPPLY MODULE
Maximum input voltage70 V
Minimum input voltage14 V
Nominal input voltage30 V
JESD-30 codeR-XSMA-X11
length168 mm
Number of functions1
Output times2
Number of terminals11
Maximum operating temperature71 °C
Minimum operating temperature-25 °C
Maximum output voltage12.07 V
Minimum output voltage11.93 V
Nominal output voltage12 V
Package body materialUNSPECIFIED
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Peak Reflow Temperature (Celsius)NOT SPECIFIED
surface mountNO
technologyHYBRID
Temperature levelCOMMERCIAL EXTENDED
Terminal formUNSPECIFIED
Terminal locationSINGLE
Maximum time at peak reflow temperatureNOT SPECIFIED
Maximum total power output150 W
Fine-tuning/adjustable outputYES
width111 mm
Base Number Matches1
®
K Series Data Sheet
150 Watt DC-DC and AC-DC Converters
Features
• RoHS lead-free-solder and lead-solder-exempted
products are available.
• Class I equipment
• Extremly wide input voltage ranges from 8 to 385 VDC,
and 85 to 264 VAC, 47 to 440 Hz
• Input over- and undervoltage lockout
• Adjustable output voltage with remote on/off
• 1 or 2 outputs: SELV, no load, overload, and short-
circuit proof
• Rectangular current limiting characteristic
• Immunity accord. to IEC 61000-4-2, -3, -4, -5, -6
• PCBs protected by lacquer
• Very high reliability
Safety according to IEC/EN 60950-1, UL/CSA 60950-1
111
4.4"
3U
80
3.2"
16 TE
168
6.6"
Description
The K Series of DC-DC and AC-DC converters represents a
broad and flexible range of power supplies for use in advanced
electronic systems. Features include high efficiency, high
reliability, low output voltage noise and excellent dynamic
response to load/line changes. LK models can be powered by
DC or AC with a wide-input frequency range (without PFC).
The converter inputs are protected against surges and
transients. Input over- and undervoltage lockout circuitry
disables the outputs, if the input voltage is outside of the
specified range. Certain types include an inrush current limiter
preventing circuit breakers and fuses from tripping at switch-
on.
All outputs are open- and short-circuit proof, and are protected
against overvoltages by means of built-in suppressor diodes.
The output can be inhibited by a logic signal applied to pin 18
(i). The inhibit function is not used, pin 18 must be connected
with pin 14 to enable the outputs.
LED indicators display the status of the converter and allow for
visual monitoring of the system at any time.
Full input-to-output, input-to-case, output-to-case, and output
to output isolation is provided. The converters are designed,
built, and safety-approved to the international safety standards
IEC/EN 60950-1. They are particulary suitable for railway
applications and comply with EN 50155 and EN 50121-2-3.
The case design allows operation at nominal load up to 71 °C
in a free-air ambient temperature. If forced cooling is provided,
the ambient temperature may exceed 71 °C, but the case
temperature must remain below 95 °C under all conditions.
A temperature sensor generates an inhibit signal, which
disables the outputs when the case temperature
T
C
exceeds
the limit. The outputs are automatically re-enabled, when the
temperature drops below the limit.
Various options are available to adapt the converters to
individual applications.
The converters may either be plugged into a 19 " rack system
according to IEC 60297-3, or be chassis mounted. They are
ideally suited for Railway applications.
Important:
For applications requiring compliance with IEC/EN
61000-3-2 (harmonic distortion), please use our LK4000 or
LK5000 Series with incorporated power factor correction (PFC).
Table of Contents
Page
Page
Electromagnetic Compatibility (EMC) .............................. 15
Immunity to Environmental Conditions ............................ 17
Mechanical Data ............................................................... 18
Safety and Installation Instructions .................................. 20
Description of Options ..................................................... 23
Accessories ...................................................................... 30
www.power-one.com
Description ......................................................................... 1
Model Selection .................................................................. 2
Functional Description ....................................................... 4
Electrical Input Data ........................................................... 5
Electrical Output Data ......................................................... 8
Auxiliary Functions ............................................................ 12
BCD20002-G Rev AB, 12-Jul-2010
Page 1 of 31
Microcontroller memory technology for smart batteries
Microcontroller Memory Technology for Smart Batteries (Transferred) Microcontroller Memory Technology for Smart Batteries Ron Cates, Microchip  Most smart batteries require a microcontroller (MCU). Th...
zbz0529 Power technology
Switching power supply design
[i=s] This post was last edited by paulhyde on 2014-9-15 09:43 [/i] Switching Power Supply Design.pdf...
hnbcyrnd89 Electronics Design Contest
Anyone seen the post about TI's recent seminar on the forum a few days ago? Please provide the link
[i=s]This post was last edited by dontium on 2015-1-23 12:43[/i] [color=rgb(68, 68, 68)][backcolor=rgb(255, 255, 255)]Has anyone seen the post about TI's recent seminar on the forum a few days ago? Pl...
j03128 Analogue and Mixed Signal
A newbie posted a message asking for help on porting STVD project to IAR
I have just started using IAR and don't know how to port the STVD project. After copying the header file and source file, it always reports an error saying that it is not defined: puzzle: Is it define...
有了这种人 stm32/stm8
Please guide me on how buck-boost works
As a newbie in the industry, I don't quite understand how buck-boost works. Can anyone explain it to me?...
逆乱灬 Power technology
IT communication and learning (reference)
From June 23rd to 25th, free course on zero-starting and zero-based embedded mobile game and application development Time: Every night from June 23rd to 25th (19:30-21:30) Course: Free course on zero-...
llgg9527 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 862  349  1831  2050  1254  18  8  37  42  26 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号