SINGLE-PHASE GLASS PASSIVATED
SILICON BRIDGE RECTIFIER
VOLTAGE RANGE 50 to 1000 Volts CURRENT 6.0 Amperes
FEATURES
*
*
*
*
*
Low leakage
Low forward voltage
Silver-plated copper leads
Surge overload rating: 150 amperes peak
Mounting position: Any
RBU601M
THRU
RBU607M
RBU
MECHANICAL DATA
* Epoxy: Device has UL flammability classification 94V-O
.880 (22.3)
.860 (21.8)
.160 (4.1)
.140 (3.5)
.080 (2.03)
.060 (1.52)
.740 (18.8)
.720 (18.3)
.140 (3.56)
.130 (3.30)
.512 (13.0)
.085 (2.16)
.075 (1.90)
.100 (2.54)
.085 (2.16)
.710 (18.0)
.690 (17.5)
.050 (1.27)
.040 (1.02)
.210 (5.33)
.190 (4.83)
.080 (2.03)
.065 (1.65)
.022 (0.56)
.018 (0.46)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25
o
C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
Dimensions in inches and (millimeters)
MAXIMUM RATINGS
(@ T
A
=25
O
C unless otherwise noted)
RATINGS
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
o
at T
C
= *100 C (Note 4)
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Typical Thermal Resistance (Note 1)
Operating and Storage Temperature Range
SYMBOL
V
RRM
V
RMS
V
DC
I
O
I
FSM
R
θ
JC
R
θ
JA
T
J
, T
STG
RBU601M RBU602M RBU603M RBU604M RBU605M RBU606M RBU607M
50
35
50
100
70
100
200
140
200
400
280
400
6.0
150
3.5
26
-55 to + 150
0
UNITS
Volts
Volts
Volts
Amps
Amps
0
600
420
600
800
560
800
1000
700
1000
C/ W
C
ELECTRICAL CHARACTERISTICS
(@T
A
=25
O
C unless otherwise noted)
CHARACTERISTICS
Maximum Instantaneous Forward Voltage at 6.0A DC
Maximum DC Reverse Current
at Rated DC Blocking Voltage
@T
A
= 25 C
@T
A
= 125
o
C
o
SYMBOL
V
F
I
R
RBU601M RBU602M RBU603M RBU604M RBU605M RBU606M RBU607M
1.1
5.0
300
UNITS
Volts
uAmps
2013-04
REV: A
NOTES : 1. Thermal Resistance : Heat-sink case mounted or if PCB mounted.
2. "Fully ROHS compliant", "100% Sn plating (Pb-free)".
3. Equivalent to Vishay's GBU6 Series.
4. "*" Heat Sink Temperature.
RATING AND CHARACTERISTICS CURVES ( RBU601M THRU RBU607M )
AVERAGE FORWARD OUTPUT CURRENT, (A)
INSTANTANEOUS FORWARD CURRENT, (A)
8.0
40
10
4.0
6.0
4.0
1.0
0.4
T
A
= 25
O
C
Pulse Width = 300mS
1% Duty Cycle
2.0
0
0
50
100
O
150
0.1
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
HEAT SINK TEMPERATURE, ( C)
INSTANTANEOUS FORWARD VOLTAGE, (V)
INSTANTANEOUS REVERSE CURRENT, (uA)
PEAK FORWARD SURGE CURRENT, (A)
1000
FIG.1 TYPICAL FORWARD CURRENT
DERATING CURVE
T
A
= 125 C
O
240
200
160
120
80
40
0
1
FIG.2 TYPICAL INSTANTANEOUS
FORWARD CHARACTERISTICS
8.3mS Single Half Sine-Wave
JEDEC Method
100
10
1.0
T
A
= 25
O
C
0.1
0
20
40
60
80
100
120
140
2
5
10
20
50
100
PERCENT RATED PEAK REVERSE VOLTAGE, (%)
NUMBER OF CYCLES AT 60Hz
FIG.3 TYPICAL REVERSE CHARACTERISTICS
FIG.4 MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
Marking Description
Rectron Logo
UL Logo
Year – code
(Y:Last digit of year
&A:2010,B:2011……)
RBU60XM
VYWW
Part No.
Voltage-code
1-------50V
2-------100V
3-------200V
4-------400V
5-------600V
6-------800V
7-------1000V
Week – code:
(WW:01~52)
PACKAGING OF DIODE AND BRIDGE RECTIFIERS
TUBE PACK
PACKAGE
RBU
PACKING CODE
-C
EA PER BOX
1,000
INNER BOX SIZE
(mm)
490*135*110
CARTON SIZE
(mm)
510*293*131
EA PER CARTON
2,000
WEIGHT(Kg)
13.62
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liabi-
lity for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" paramet-
ers which may be included on RECTRON data sheets and/ or specifications ca-
n and do vary in different applications and actual performance may vary over ti-
me. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other rela-
ted applications where a failure or malfunction of component or circuitry may di-
rectly or indirectly cause injury or threaten a life without expressed written appr-
oval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rect-
ron Inc and its subsidiaries harmless against all claims, damages and expendit-
ures.