EEWORLDEEWORLDEEWORLD

Part Number

Search

ABS1618513

Description
Snap Acting/Limit Switch, SPDT, Momentary, 0.1A, 30VDC, 7mm, Wire Terminal, Leaf Lever Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size276KB,11 Pages
ManufacturerPanasonic
Websitehttp://www.panasonic.co.jp/semicon/e-index.html
Environmental Compliance
Download Datasheet Parametric View All

ABS1618513 Overview

Snap Acting/Limit Switch, SPDT, Momentary, 0.1A, 30VDC, 7mm, Wire Terminal, Leaf Lever Actuator, Panel Mount

ABS1618513 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Reach Compliance Codecompli
ECCN codeEAR99
Actuator stroke7 mm
Actuator typeLEAF LEVER
body width6.4 mm
body height16.9 mm
Body length or diameter21.2 mm
Contact (AC) maximum rated R load.1A@250VAC
Maximum contact current (AC)0.1 A
Maximum contact current (DC)0.1 A
Contact (DC) maximum rated R load.1A@30VDC
Maximum contact voltage (AC)250 V
Maximum contact voltage (DC)30 V
Electrical life200000 Cycle(s)
JESD-609 codee4
Manufacturer's serial numberABS1
Installation featuresPANEL MOUNT
Maximum operating force1.08 N
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
Maximum pre-travel4.5 mm
sealENVIRONMENTALLY SEALED; IP67
surface mountNO
Switch actionMOMENTARY
switch functionSPDT
Switch typeSNAP ACTING/LIMIT SWITCH
Terminal surfaceGold (Au)
Termination typeWIRE
Base Number Matches1
VDE
HIGH ENVIRONMENTAL
RESISTANCE
TURQUOISE SWITCHES
ABS TYPE
FEATURES
19.3
11.1
6.4
• Subminiature size (19.8×11.1×6.4 mm)
• Sealed construction for use in adverse environment-Sealed construction by
epoxy resin and rubber cap greatly reduces possible miscontact due to
contaminants such as dust. Conforming to IP67* of IEC protective construction
classification
• Elastomer double molding technology, an industry first and ultrasonic swaging
technology contribute to uniform sealing in high production quantities
• Expansion of low-level circuit type
• We offer a Au clad 2-ply contact type (for small loads) that we developed
specifically for small current and voltage loads in the range of 1 mA to 100 mA
and 5 V to 30 V.
• UL/CSA/VDE/SEMKO approved
(AS for Au-clad twin layer, VDE and SEMKO are not approved.)
* Based on the protective construction classification of IEC, items which satisfy the test
requirements are denoted with an IP designation.
TYPICAL APPLICATIONS
RoHS compliant
• Automotive
• Home appliances (vacuum cleaner, air purifier)
• Others (gas cooking range)
ORDERING INFORMATION
Ex. ABS
1
1
1
0
4
0
3
Operating
Type of
Contact
force by
Terminal
Actuator
Contact*
Agency standard
switch
arrangement
pin plunger
(max.)
ABS:
1: Straight type 1: .110 quick-connect 1: SPDT
0: Pin plunger
4: 0.98 N
0: AgNi alloy
3: UL/CSA/VDE/SEMKO
Turquoise 4: Right angle
terminal
2: SPST-NC 1: Short hinge lever 5: 1.47 N
1: Au-clad
(AgNi alloy contact,
switch
5: Left angle
4: Solder terminal
3: SPST-NO 2: Hinge lever
triple layer
Au-clad triple layer type)
S type
5: PC board terminal
3: Long hinge lever
4: Au-clad
9: UL/CSA
6: Wire leads
4: Simulated roller
double layer
(Au-clad double layer type)
lever
6: Roller lever
8: Leaf lever
Wire and
terminal
position
Remarks: 1.
2.
3.
4.
5.
Standard packing: Dust protected type 100 pcs./carton, 1,000 pcs./case; Immersion protected type 50 pcs./case.
SPST-NC and SPST-NO are only available for wire leads type.
Leaf lever is only available for wire leads type
Wire leads type with agency standard will be discontinued from August 31, 2012.
As for wire position:
Straight type
Wire opposite to the
actuator side type
(Right angle)
Wire actuator side type
(Left angle)
5. Not every combination is available. Please refer to the following table, “PRODUCT TYPES”.
* Contact
0: AgNi alloy
AgNi alloy
1: Au-clad triple layer
Au-clad
CuNi alloy
AgNi alloy
4: Au-clad double layer
Au-clad
CuNi alloy
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e
AECTB2E 201201-T
How to get the device name under winCE
How can I know the device names of the devices on the board? For example, I want to find the device name of the LCD, but I can't find it even after searching the Display driver. However, related funct...
faulkner Embedded System
6LoWPAN Network Construction
I want to use CC2650 and other development boards to build a Contiki/6LoWPAN intranet and LAN. Taking cc26xx-web-demo as an example, I would like to ask a few questions: 1. Can CC2650DK be used for bo...
QQ3283302972 RF/Wirelessly
【AT-START-F425 Review】+ Serial Port Idle Interrupt and DMA
0. Introduction In the previous section, the serial port idle interrupt and receive interrupt were used to implement serial port variable length data reception. This article uses DMA to receive serial...
freeelectron Domestic Chip Exchange
Laobai learns Linux--Analysis of BUG_ON and WARN_ON
BUG_ON and WARN_ON in linux are mainly used for debugging. 1. BUG_ON #define BUG_ON(condition) do { / if (unlikely((condition)!=0)) / BUG(); / } while(0) If you think there is a BUG under this conditi...
白丁 Linux and Android
Use of DSP guidance function
TI's high-speed digital signal processor TMS320C6000 series DSP supports parallel processing and adopts a very long instruction word (VLIW) architecture. It has 8 functional units (two multipliers and...
Aguilera DSP and ARM Processors
Learn FPGA from Teacher Xia (14) When learning FPGA, should I choose Verilog or VHDL?
[flash]http://www.tudou.com/v/zai8jC6r6rg/v.swf[/flash]...
soso FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2729  1596  1393  2870  2527  55  33  29  58  51 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号