EEWORLDEEWORLDEEWORLD

Part Number

Search

KWAETAAB

Description
Snap Acting/Limit Switch, SPST, Momentary, 0.05A, 28VDC, 2.92mm, Quick Connect Terminal, Straight Type Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size114KB,2 Pages
ManufacturerThe Cherry Corporation
Download Datasheet Parametric View All

KWAETAAB Overview

Snap Acting/Limit Switch, SPST, Momentary, 0.05A, 28VDC, 2.92mm, Quick Connect Terminal, Straight Type Actuator, Panel Mount

KWAETAAB Parametric

Parameter NameAttribute value
Reach Compliance Codeunknown
ECCN codeEAR99
Actuator stroke2.92 mm
Actuator typeSTRAIGHT TYPE
body width10.31 mm
body height15.88 mm
Body length or diameter28.96 mm
Maximum contact current (DC)0.05 A
Contact (DC) maximum rated R load.05A@28VDC
Maximum contact voltage (DC)28 V
Electrical life100000 Cycle(s)
Manufacturer's serial numberK
Installation featuresPANEL MOUNT
Maximum operating force0.25 N
Maximum operating temperature150 °C
Minimum operating temperature-40 °C
Maximum pre-travel1.63 mm
surface mountNO
Switch actionMOMENTARY
switch functionSPST
Switch typeSNAP ACTING/LIMIT SWITCH
Termination typeQUICK CONNECT
Base Number Matches1
MINIATURE
K Series
Features
Choice of current ratings up to 25 amps
Choice of actuators
Choice of terminals
3 contact arrangements
Choice of operating force
Long mechanical life
Wiping contact action
Snap over actuators
Agency approved extended life versions
Flame retardant, UL94V-O
self-extinguishing
case and cover
Long-life snap action
switch mechanism
ARC-resistant case
has internal barriers,
4mm minimum between
live parts and external
hardware
NC terminal
NO terminal
International Approved Versions
K Series switches, except 25A (KWS), are
internationally approved. Switches with
straight terminals may require insulated
connectors for international approval.
Choice of U.S. (#4 screw)
or metric (3mm screw)
Common terminal
Single or double throw, either
normally open or normally closed
Electrical Ratings
Switch
Series
EN61058 Rating
UL1054 Rating
Electrical Life at Rated Load
According to VDE
According to UL
(Min. Operations)
(Min. Operations)
KWA/KWB
KWC/KWD
KWE/KWF
KWG/KWH
KWJ/KWK
KWL
50mA, 28VDC
1(0.5)A, 250VAC
3(1)A, 250VAC
6(2)A, 250VAC
10(3)A, 250VAC
N/A
KWM
16(4)A, 250VAC
KWS
N/A
50mA, 28VDC
1.0A, 125/250VAC
3A, 1/10HP, 125/250VAC
5A, 1/4HP, 125/250VAC
10A, 1/2HP, 125/250VAC
15.1A, 1/2HP, 125/250 VAC
5A, 125VAC Lamp Load
(85°C only)
0.5A, 125VDC
(85°C only)
0.25A, 250VDC
(85°C only)
15.1A, 1/2HP, 125/250VAC
0.5A, 125VDC
(85°C and 150°C only)
0.25A, 250VDC
(85°C and 150°C only)
15.1A, 1/2HP, 125/250VAC
(200°C only)
25A, 125/250VAC
(85°C only)
1HP, 125VAC
(85°C only)
2HP, 250VAC
(85°C only)
50,000
50,000
50,000
50,000
50,000
N/A
100,000
100,000
100,000
100,000
100,000
100,000
50,000
100,000
N/A
100,000
Specifications
Electrical
Temperature Rating:
Flammability Rating:
Materials
-40° to +85°C, 150°C or 200°C
UL94V-O
Thermoplastic Polyester (85°C or 150°C)
Liquid Crystal Polymer (200°C)
Thermoplastic Acetal (85°C)
Thermoplastic Polyester (150°C)
Liquid Crystal Polymer (200°C)
Cold-Rolled Steel (Nickel-Plated)
Brass
Copper (25 amp only)
Beryllium Copper
Silver Alloy
(except KWA and KWB — Gold-Plated)
Case/Cover:
Button:
Auxiliary Actuator:
Terminals:
Moving Blade:
Contacts:
Classification of hazardous areas
According to the classification of hazardous environments formulated by the International Electrotechnical Commission (IEC), under atmospheric conditions, dust or fibrous combustible substances and ai...
紫霞湖 Industrial Control Electronics
I need help with a SMD device model
I'm asking for help from the almighty forum. Can any experts tell me what the full name of this material is? I looked it up myself and it might be SMBJ75A, but I can't be sure. So please help me, than...
眼大5子 Integrated technical exchanges
Analog Electronics Technical Data
Analog electronic technology information, teach you from the very basics...
sjs199023 Power technology
MSP430 dual serial port communication problem
I'm new to microcontrollers and have only written simple applications before. My current job requires me to use 430 as a gateway, which requires two serial ports. That is, the data received by serial ...
sint27 Microcontroller MCU
Does the max6675 read data on the rising edge or the falling edge?
When using max6675 and thermocouple to detect temperature, does max6675 read data on the rising edge or the falling edge of the clock pulse?...
喜鹊王子 51mcu
Why can't the overall program run after adding the program of external data memory 62256?
Can you guys help me see if there is any problem with my 62256 reading and writing program? uchar idata dig1[7]={"4 8.5 0"}; void WR62256() { uchar i; addr=0x0100;//Starting address of data storage fo...
ccjchen MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 442  2451  1100  2767  251  9  50  23  56  6 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号