EEWORLDEEWORLDEEWORLD

Part Number

Search

HQCD-060-03.75-STL-SBL-4

Description
Interconnection Device, ROHS COMPLIANT
CategoryThe connector    The connector   
File Size2MB,8 Pages
ManufacturerSAMTEC
Websitehttp://www.samtec.com/
Environmental Compliance  
Download Datasheet Parametric View All

HQCD-060-03.75-STL-SBL-4 Overview

Interconnection Device, ROHS COMPLIANT

HQCD-060-03.75-STL-SBL-4 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
Connector typeINTERCONNECTION DEVICE
Base Number Matches1
REVISION U
VERTICAL
(HQCD-060-XX.XX-STR-STR-1 SHOWN)
FIG. 1
HQCD-XXX-XX.XX-XXX-XXX-X-X
No OF POSITIONS
-030, -060, -090, -120
(PER ROW)
LENGTH
-XX.XX (INCHES)
(03.75[95.3] MIN)
(SEE NOTE 2)
(SEE NOTE 8)
FIRST END
-TTR: TERMINAL, TOP, RIGHT
-TTL: TERMINAL, TOP, LEFT
-TBR: TERMINAL, BOTTOM, RIGHT
-TBL: TERMINAL, BOTTOM, LEFT
-STR: SOCKET, TOP, RIGHT
-STL: SOCKET, TOP, LEFT
-SBR: SOCKET, BOTTOM, RIGHT
-SBL: SOCKET, BOTTOM, LEFT
(SEE TABLE 1 & SHEET 2)
-TEU: TERMINAL, EDGE MOUNT, UP
-TED: TERMINAL, EDGE MOUNT, DOWN
-SEU: SOCKET, EDGE MOUNT, UP
-SED: SOCKET, EDGE MOUNT, DOWN
(SEE TABLE 5 & SHEET 4)
-TPU: TERMINAL, PANEL MOUNT, UP
-TPD: TERMINAL, PANEL MOUNT, DOWN
-SPU: SOCKET, PANEL MOUNT, UP
-SPD: SOCKET, PANEL MOUNT, DOWN
(SEE TABLE 11 & SHEET 6)
(ONLY AVAILABLE ON -030,-060, AND -090)
END OPTION
-F: SCREW OPTION FIRST END ONLY (NOT AVAILABLE
WITH XPX OPTIONS)
-S: SCREW OPTION SECOND END ONLY
-B: SCREW OPTION BOTH ENDS (NOT AVAILABLE
WITH XPX OPTIONS)
-N: NO CAPS
-L: FIRST END RT1 OPTION (SEE NOTES 9 & 10)
-R: SECOND END RT1 OPTION (SEE NOTES 9 & 10)
-D: BOTH ENDS RT1 OPTION (SEE NOTES 9 & 10)
-1: FIRST END SCREW OPTION,
SECOND END RT1 OPTION (SEE NOTES 9 & 10)
-2: FIRST END RT1 OPTION,
SECOND END SCREW OPTION (SEE NOTES 9 & 10)
(SEE FIG. 3, SHEET 5 FOR EDGE MOUNT
END OPTIONS)
(SEE FIG. 4, SHEET 5 FOR DOUBLE
VERTICAL END OPTIONS)
(SEE FIG. 5, SHEET 5 FOR NO CAPS)
(LEAVE BLANK FOR STANDARD CAPS
BOTH ENDS)
WIRING OPTION
-1: PIN 1 TO PIN 1
-2: PIN 1 TO PIN 2
-3: PIN 1 TO PIN N-1
-4: PIN 1 TO PIN N
(SEE TABLE 9, SHEET 6)
SECOND END
-TTR: TERMINAL, TOP, RIGHT
-TTL: TERMINAL, TOP, LEFT
-TBR: TERMINAL, BOTTOM, RIGHT
-TBL: TERMINAL, BOTTOM, LEFT
-STR: SOCKET, TOP, RIGHT
-STL: SOCKET, TOP, LEFT
-SBR: SOCKET, BOTTOM, RIGHT
-SBL: SOCKET, BOTTOM, LEFT
(SEE TABLE 1 & SHEET 3)
-TEU: TERMINAL, EDGE MOUNT, UP
-TED: TERMINAL, EDGE MOUNT, DOWN
-SEU: SOCKET, EDGE MOUNT, UP
-SED: SOCKET, EDGE MOUNT, DOWN
(SEE TABLE 5 & SHEET 4)
DO NOT
SCALE FROM
THIS PRINT
SUB-HQCD-X-XXX-XX-XX
01
LENGTH: XX.XX + "L" REF (SEE TABLE 4)
C1
LENGTH: XX.XX 1%
01
02
02
'A'
"A" REF
(TYP)
"B" REF
(TYP)
N-1
(SEE TABLE 3)
.565 14.35
REF (TYP)
.775 19.69 REF
(TYP)
N-1
(SEE TABLE 3)
N
(SEE TABLE 3)
N
(SEE TABLE 3)
SUB-HQCD-X-XXX-XX-XX
STS-01
(TIGHTEN TO 1.4 - 1.7 IN-LBS)
(4 PLCS)
QCD-XX-01
HDRL-11
(SEE NOTE 5)
.253 6.42 REF (TYP)
FIRST END
SECOND END
LENGTH REF
* "C" REF
NOTES:
C
REPRESENTS A CRITICAL DIMENSION.
1.
2. SUB-TCF LENGTH IS EQUAL TO HQCD LENGTH.
C2
3. ALL ASSEMBLIES TO BE 100% ELECTRICALLY TESTED
QCD-XX-02
FOR SHORTS AND OPENS.
SUB-TCF-3850-30-01-XX.XX
C3
4. ALL ASSEMBLIES TO BE 100% HI-POT TESTED AT 300V.
(SEE TABLE 1 FOR QTY)
5. TOP SUB-TCF NOT SHOWN IN THIS VIEW FOR CLARITY; HDRL-11 TO BE CENTERED ON LOWER
SUB-TCF AS SHOWN; HDRL-11 IS TO CONTAIN:
LINE 1 - PART NUMBER “HQCD-XXX-XX.XX-XXX-XXX-X-X”
LINE 2 - SHOP ORDER NUMBER “XXXXXX”
LINE 3 - DATE CODE “XXXXX”
THIS PRODUCT MANUFACTURED
Pb
6. FOR PACKAGING REQUIREMENTS REFERENCE PACKAGING STANDARDS.
WITH LEAD-FREE PROCESSING
* -DV END OPTIONS ONLY
7. PARTS TO BE PROCESSED PER SAMTEC ACCEPTABILITY
REQUIRMENTS: HDR-P1-01 "CABLE ASSEMBLY WORKMANSHIP STANDARDS".
PROPRIETARY NOTE
UNLESS OTHERWISE SPECIFIED,
8. CABLE LENGTHS LONGER THAN 40.00 INCHES ARE NOT SUPPORTED BY S.I. TEST DATA.
DIMENSIONS ARE IN INCHES.
THIS DOCUMENT CONTAINS INFORMATION
CONFIDENTIAL AND PROPRIETARY TO
9. RT1 OPTION IS NOT AVAILABLE WITH EDGEMOUNT OR PANEL MOUNT END OPTIONS.
TOLERANCES ARE:
SAMTEC, INC. AND SHALL NOT BE REPRODUCED
10. RT1 OPTION IS NOT AVAILABLE WITH -120 POSITIONS.
DECIMALS
ANGLES
OR TRANSFERRED TO OTHER DOCUMENTS OR
DISCLOSED TO OTHERS OR USED FOR ANY
11. ALL POSITIONS TRANSMITTED AS SIGNALS ACROSS COAX CENTER CONDUCTORS. CONNECTOR
.XX: .01 [.3]
2
PURPOSE OTHER THAN THAT WHICH IT WAS
.XXX: .005 [.13]
GROUND BLADE TIED TO COAX SHIELD.
OBTAINED WITHOUT THE EXPRESSED WRITTEN
.XXXX: .0020 [.051]
CONSENT OF SAMTEC, INC.
DETAIL 'A'
SCALE 2.5 : 1
520 PARK EAST BLVD, NEW ALBANY, IN 47150
PHONE: 812-944-6733
FAX: 812-948-5047
e-Mail: info@SAMTEC.com
code: 55322
MATERIAL:
DO NOT SCALE DRAWING
SHEET SCALE: 1:0.8
DESCRIPTION:
DWG. NO.
0.5mm HIGH-SPEED COAX CABLE ASSEMBLY
HQCD-XXX-XX.XX-XXX-XXX-X-X
04/29/03
SHEET
1
OF
8
c:\enterprisevault\DWG\MISC\MKTG\HQCD-XXX-XX.XX-XXX-XXX-X-X-MKT.SLDDRW
BY:
KEVIN B
PCB board medium temperature and humidity test
Source: PCB Resource Network Author: PCB Resource Network Release Date: 2008-06-21 1. Temperature and humidity test of PCB board The comprehensive test chamber consists of a refrigeration system, a he...
安_然 Test/Measurement
How to effectively reduce slices?
During the design, it was found that the logic slice occupancy was 106%. How can it be effectively reduced?...
f_w2010 FPGA/CPLD
Ask about Silverlight for Embedded hardware acceleration
I have compiled the Silverlight demo for WinCE 6 R3 successfully, but the demo's frame rate has been kept at 1 to 3 frames. I have tried everything but it doesn't work. The settings I have made are as...
fgq20000 Embedded System
Characteristic impedance issues of PCB technology in high-speed design
http://www.hampoo.comIn high-speed design, the characteristic impedance of controlled impedance boards and lines troubles many Chinese engineers. This article introduces the basic properties, calculat...
wswnihao PCB Design
Do you know all about LC resonant circuit?
Depending on how the inductor L and the capacitor C are connected in the circuit, there are two types of LC resonant circuits, LC parallel resonant circuit and LC series resonant circuit. LC parallel ...
Aguilera Analogue and Mixed Signal
sql ce read data abnormality
Dear experts: My database is named test.sdf and there is a user table in it, but an exception occurs when SqlCeDataReader dr = cmd.ExecuteReader(); The program is as follows: string constr="Data Sourc...
x810421 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 829  1689  178  993  1279  17  35  4  20  26 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号