Electric Fuse, Time Lag Blow, 0.125A, 35A (IR), 5x20mm,
CategoryCircuit protection    Circuit protection   
File Size299KB,2 Pages
ManufacturerEaton
Environmental Compliance
Download Datasheet Parametric View All

BK1/S506-V-125-R Overview

Electric Fuse, Time Lag Blow, 0.125A, 35A (IR), 5x20mm,

BK1/S506-V-125-R Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Reach Compliance Codecompliant
Fusing characteristicsTIME LAG
body height21.1 mm
Body length or diameter5.54 mm
Circuit protection typeElectric Fuse
Fuse size5x20mm
physical size5.54mm x 21.1mm
Pre-discharge rating0.063 A2/s
Rated breaking capacity35 A
Rated current0.125 A
Rated voltage250 V
GuidelineBSI, CCC, CSA, IMQ, SEMKO, UL, VDE
Terminal shapeEND CAP
Base Number Matches1
5 x 20mm Fuses
S506 Series, Time-Delay, Glass Tube
Description
• Time-delay, low breaking capacity
• Optional axial leads available
• 5 x 20mm physical size
• Glass tube, nickel-plated brass endcap construction
• Designed to IEC 60127-2/3 (32mA-10A) &
extensions:12.5A-15A
S506 Electrical Characteristics
2.1 In
2.75 In
4 In
In
max
min
max
min
max
32mA-100mA 2 min 200 ms 10 sec 40 ms 3 sec
125mA-6.3A 2 min 600 ms 10 sec 150 ms 3 sec
8A-15A
2 min 600 ms 10 sec 150 ms 3 sec
10 In
min
max
10 ms 300 ms
20 ms 300 ms
20 ms 300 ms
Dimensions - mm
Drawing Not to Scale
Agency Information
• UL Recognized Card: Guide JDYX2, File E19180
• CSA Component Acceptance: File 1803366
• cURus Recognition: Guide JDYX8, File E19180
• SEMKO Approval: File 507078, 415434, 806492
• VDE Approval: File 40011926
• BSI Approval: File KM55676
• IMQ Approval: File E1921, CA03.00530
• PSE/JET: File JET1641-31003-1005,
JET1641-31003-1006
• CCC Approval: File 2005010207155693,
2002010207011294
• Ratings above 4A have a 0.81mm diameter lead
Ordering
Specify product code
• Insert packaging code prefix before part number. E.g.
BK/S506-1-R
Specify option code if desired
• For axial leads, insert “V” between catalog series and
amp rating. E.g. BK/S506-V-2-R
Specifications
Product
Code
S506-32-R
S506-40-R
S506-50-R
S506-63-R
S506-80-R
S506-100-R
S506-125-R
S506-160-R
S506-200-R
S506-250-R
S506-315-R
S506-400-R
S506-500-R
S506-630-R
S506-800-R
S506-1-R
S506-1.25-R
S506-1.6-R
S506-2-R
S506-2.5-R
S506-3.15-R
S506-4-R
S506-5-R
S506-6.3-R
S506-8-R
S506-10-R
S506-12.5-R
S506-15-R
Voltage Interrupting Rating
Typical DC
Typical
Typical
Agency Approvals
Rating (amps) at Rated Cold Resistance Melting I
2
t Voltage IMQ VDE BSI SEMKO UR CCC PSE/ CSA cURus
Vac Voltage (50Hz) Vac
(Ω)*
(amps) Drop (mV)‡
JET
250
35
21.0
0.0051
1050
X
X
X
X
X
X
250
35
13.90
0.0072
920
X
X
X
X
X
X
250
35
9.24
0.0095
800
X
X
X
X
X
X
X
250
35
6.96
0.021
760
X
X
X
X
X
X
X
250
35
4.42
0.038
580
X
X
X
X
X
X
X
250
35
2.80
0.045
490
X
X
X
X
X
X
X
250
35
1.97
0.063
390
X
X
X
X
X
X
X
250
35
1.27
0.093
320
X
X
X
X
X
X
X
250
35
1.00
0.114
340
X
X
X
X
X
X
X
250
35
0.640
0.265
270
X
X
X
X
X
X
X
250
35
0.450
0.621
250
X
X
X
X
X
X
X
250
35
0.31
0.872
210
X
X
X
X
X
X
X
250
35
0.183
0.827
140
X
X
X
X
X
X
X
X
250
35
0.186
1.33
150
X
X
X
X
X
X
X
X
250
35
0.129
2.78
75
X
X
X
X
X
X
X
X
250
35
0.0757
6.45
87.5
X
X
X
X
X
X
X
X
X
250
35
0.060
10.05
86
X
X
X
X
X
X
X
X
X
250
35
0.0425
21.7
82
X
X
X
X
X
X
X
X
X
250
35
0.03325
31.6
77
X
X
X
X
X
X
X
X
X
250
35
0.0255
59.4
72.5
X
X
X
X
X
X
X
X
X
250
35
0.0185
96.4
68.5
X
X
X
X
X
X
X
X
X
250
40
0.0139
71.8
67
X
X
X
X
X
X
X
X
X
250
50
0.00985
142.5
60.5
X
X
X
X
X
X
X
X
X
250
63
0.0071
237.6
54
X
X
X
X
X
X
X
X
X
250
80
0.007
255.8
55
X
X
X
X
X
X
X
X
250
100
0.005
450
54
X
X
X
X
X
X
X
X
250
125
0.004
1019.5
45
X
X
X
250
125
0.004
1091.7
65.5
X
X
X
* DC Cold Resistance (measured at <10% of rated current)
‡ Typical Voltage Drop (voltage drop was measured at 20°C ambient temperature at rated current)
0709
BU-SB08673
Page 1 of 2
Data Sheet 4332
How to wrap lines in canvas strings
Please advise:How to implement string wrapping in canvas control?...
colecole888 Microcontroller MCU
How to tell if a node is connected to the network via routing?
Now there is a coordinator and two routers 1 and 2. Now I want to let router 2 connect to the network through router 1 and then exchange data with the coordinator . But how can I be sure that router 2...
高兴就好 RF/Wirelessly
Common sense in choosing rental car models
1. The heavier the car, the more fuel it consumes From the perspective of fuel saving, the car's own weight is directly proportional to its fuel consumption, that is, the heavier the car, the more fue...
iitang Talking
LM5007 switching power supply chip interference problem
I have used LM5007 as a power supply these days, but I found that the interference is very severe. There is analog sampling on the board, and there are too many high-frequency noises. It is very unsta...
freak Analogue and Mixed Signal
Share the process of WEBENCH design + LED toys made for children
For some purpose, I want to make toys again. I can try Webench to make a small toy. So open the page [url]http://www.ti.com.cn/lsds/ti_zh/analog/webench/overview.page[/url] Since it is a small toy, th...
sjtitr Analogue and Mixed Signal
How to learn ARM for beginners?
I want to develop an industrial Ethernet product on an ARM platform. However, I have never used ARM before. How can I get started quickly?...
compareview ARM Technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2845  2655  1091  1279  880  58  54  22  26  18 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号