100W Modified Sine Wave DC-AC Power Inverter
A301/302-100
series
■
Features :
Built-in USB interface
Cooling by free air convection(without fan)
Slim size can fit in with the cup holder on vehicles
High efficiency up to 90%
12V or 24V DC input
Input voltage range: -15% ~ +25%
Output voltage regulation:
±
10%
Protections: Input reverse polarity/Bat. Low shutdown/Over voltage/
Over load/Over temperature/Output short
Output waveform: Modified sine wave
Topology: Microprocessor
Approvals: e13/ CE
1 year warranty
A301-100-F3
SAFETY MODEL NO.
AC RATED VOLTAGE
RATED POWER
SURGE POWER
OUTPUT
WAVEFORM
FREQUENCY
AC REGULATION
STANDARD RECEPTACLES
LED INDICATOR
USB POWER
DC CURRENT
NO LOAD CURRENT DRAW
DC VOLTAGE
INPUT
VOLTAGE RANGE
EFFICIENCY (Typ.)
DC CONNECTOR
FUSE
BAT. LOW SHUTDOWN
OVER VOLTAGE
PROTECTION OVER TEMPERATURE
OUTPUT SHORT
REVERSE. POLARITY
WORKING TEMP.
ENVIRONMENT
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
ISOLATION RESISTANCE
A-100-150W(N)
Note.1
230V
SPECIFICATION
ORDER NO.
A302-100-F3
100W
200W
Modified Sine Wave
50Hz
±
1%
±10%
Europe*1ea
Dual-color indicator display for power on / failure status
5VDC / 500mA (max.)
15A
0.25A
12V
10 ~ 15VDC
90%
650
±
50mm Cigarette plug*1ea
15A* 1ea
10
±
0.5V
15 ~ 17V
60
±
5
℃
/ 140
±
9 F (case)
o
±10%
5VDC / 300mA (max.)
10A
0.2A
24V
21 ~ 30VDC
10A* 1ea
19.5
±
1V
30 ~ 32V
Shut-off
By fuse open
0 ~ +30
℃
@100% load, 40
℃
@ 50% load
20% ~ 90% RH non-condensing
-30 ~ +70
℃
/ -22 ~ +158
o
F, 10 ~ 95% RH
±
0.05% /
℃
(0 ~ 50
℃
)
I/P-O/P:100M Ohms min./ 500VDC / 25
℃
/ 70% RH
Compliance to EN55022 class B, 72/ 245/ CEE, 2006/96/CE
Compliance to EN61000-4-2,3
Compliance to EN60950-1
ψ65*170mm
(Diameter*L)
0.55Kg ; 30pcs / 17.5Kg / CARTON
By air convection
Home appliance, office and portable equipment and vehicle ...etc.
SAFETY & EMI RADIATION
EMS IMMUNITY
EMC
LVD
DIMENSION
PACKING
COOLING
APPLICATIONS
OTHERS
NOTE
1. AC rated output voltage is measured at 12.5VDC, 25VDC input voltage.
File Name: A301/302-100-SPEC 2016-04-06