EEWORLDEEWORLDEEWORLD

Part Number

Search

DC635A561KA5306

Description
Feed Through Capacitor, 1 Function(s), 50V,
CategoryAnalog mixed-signal IC    filter   
File Size113KB,4 Pages
ManufacturerAVX
Download Datasheet Parametric View All

DC635A561KA5306 Overview

Feed Through Capacitor, 1 Function(s), 50V,

DC635A561KA5306 Parametric

Parameter NameAttribute value
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresSILVER TERMINATION
capacitance560 µF
diameter3.81 mm
filter typeFEED THROUGH CAPACITOR
high1.52 mm
Minimum insulation resistance100000 MΩ
Manufacturer's serial numberDC63
Installation typePANEL MOUNT
Number of functions1
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
physical sizeD3.81XH1.52 (mm)/D0.15XH0.06 (inch)
Rated voltage50 V
Base Number Matches1
Discoidal MLC
Feed-Through Capacitors and Filters
DC Style (US Preferred Sizes)
APPLICATION INFORMATION ON DISCOIDAL
LOWEST CAPACITANCE IMPEDANCES TO GROUND
A discoidal MLC capacitor has very low impedance associated with its ground path since the signal is
presented with a multi-directional path. These electrode paths, which can be as many as 100, allow for low
ESR and ESL which are the major elements in impedance at high frequencies.
The assembled discoidal element or feed-thru allows signal to be fed in through a chassis or bulkhead,
conditioned as it passes through the discoidal, and isolated by the chassis and discoidal from the original
signal. An example of this application would be in an AFT circuit where the AC noise signal would be required
to be stripped from the DC control signal. Other applications include single line EMI/RFI suppression, L-C
filter construction, and coaxial shield bypass filtering.
The shape of the discoidal lends itself to filter construction. The short length allows compact construction
where L-C construction is desired. The size freedom associated with this element allows almost any inside/
outside diameter combination. By allowing the inside diameter to equal the center insulator diameter of a
coaxial signal line and special termination techniques, this device will allow bypass filtering of a floating shield
to ground.
* Discoidal capacitors are available in two (2) temperature coefficients (C0G, X7R) and a variety of shapes
and sizes, the most standard of which appear on pages 102 and 13.
* Custom designed capacitor arrays are available in an unlimited number of configuration with a wide
range of rating voltages (50–2000) and temperature coefficients (NPO, BX, BR, X7R) please see page 121.
For additional information please contact AVX.
INSERTION LOSS
0
-10
OD*
ID
T Max.
These surfaces are metallized
.127 (0.005). minimum wide except
for DC61, DC26 and DC63
where metallized surfaces
are .127 (0.005) maximum.
*Tol. = +.254 (0.010) or 3%, whichever is greater
-
AVX’s DC Series 50V, 100V, 200V, C0G
and X7R parts are capable of meeting
the requirements of MIL-PRF-31033.
-20
-30
SINGLE CHIP
(dB)
-40
-50
-60
-70
-80
0
100
200
300
400
500
600
DISCOIDAL
700
800
900
1000
ELECTRICAL SPECIFICATIONS
Temperature Coefficient
C0G: A Temperature Coefficient - 0 ±30 ppm/°C, -55° +125°C
X7R: C Temperature Coefficient - ±15%, -55° to +125°C
Capacitance Test
(MIL-STD-202 Method 305)
C0G: 25°C, 1.0±0.2 Vrms at 1KHz, for ≤100 pF use 1 MHz
X7R: 25°C, 1.0±0.2 Vrms at 1KHz
Dissipation Factor 25°C
C0G: 0.15% Max @ 25°C, 1.0±0.2 Vrms at 1KHz, for ≤100 pF use 1 MHz
X7R: 2.5% Max @ 25°C, 1.0±0.2 Vrms at 1KHz
Insulation Resistance 25°C
(MIL-STD-202 Method 302)
C0G and X7R: 100K MΩ or 1000 MΩ-μF, whichever is less.
f (MHz)
Insulation Resistance 125°C
(MIL-STD-202 Method 302)
C0G and X7R: 10K MΩ or 100 MΩ-μF, whichever is less.
Dielectric Withstanding Voltage 25°C
(Flash Test)*
C0G and X7R: 250% rated voltage for 5 seconds with 50 mA max
charging current. 500V rated units will be tested at 750 VDC
Life Test
(1000 hrs)
C0G and X7R: 200% rated voltage at +125°C
(500 Volt units @ 600 VDC)
Moisture Resistance
(MIL-STD-202 Method 106)
C0G, X7R: Ten cycles with no voltage applied.
Thermal Shock
(MIL-STD-202 Method 107, Condition A)
Immersion Cycling
(MIL-STD-202 Method 104, Condition B)
HOW TO ORDER
DC61
5
A
561
K
A
Test
Level
A = Standard
Not RoHS Compliant
5
1
06
AVX
Voltage Temperature
Style
50V = 5
Coefficient
See Pages 100V = 1
C0G = A
119-120 200V = 2
X7R = C
500V = 7
Capacitance Code
Capacitance
(2 significant digits
Tolerance
+ no. of zeros)
C0G: J = ±5%
Examples:
K = ±10%
M = ±20%
10 pF = 100
X7R: K = ±10%
100 pF = 101
M = ±20%
1,000 pF = 102
22,000 pF = 223
220,000 pF = 224
Termination
Inside
Maximum
5 = Silver
Diameter
Thickness
(AVX Standard) See Pages 04 = 1.02 (0.040)
A = Unterminated 117-119 06 = 1.52 (0.060)
7 = SnNi w/Aμ Sputter
10 = 2.54 (0.100)
(100μ inches)
For dimensions, voltages or values not specified, please consult factory.
118
Zigbee control electric fan
I now have a ZigBee board and a DC fan (DC motor). How do I build the hardware circuit? What else do I need? How does the ZigBee control signal control the speed of the DC motor? Can I add an msp430 b...
潇雨如烟6 RF/Wirelessly
About the equivalent series resistance problem
For a 700mH large coil (similar to the coil of a contactor), the Rs is 270Ω when tested with a benchtop LCR bridge, but only 77Ω when tested directly with a multimeter resistance range. Therefore, how...
呜呼哀哉 Analog electronics
【Keysight Essay Call】Keysight & HP customers all over the world
My article is published in word format, in the attachment. [b][color=#5E7384]This content is originally created by EEWORLD forum netizen [size=3]Daqin Zhengsheng[/size]. If you want to reprint or use ...
大秦正声 Test/Measurement
stm32 controls LCD1602 display, but the screen always displays two blank spaces, and the letter p is displayed as the letter r. Can you guys see what the problem is?
Guys, my LCD 1602 display always starts with two spaces, and the letter P is displayed as the letter R. What is the reason? Please help me....
ybxdn stm32/stm8
Ultra-High Resolution ADC with PGA for Seismic Monitoring and Energy Development
[b] Ultra-High Resolution Sigma-Delta ADC with PGA for Seismic Monitoring and Energy Development Data. The ADS1282 is an extremely high performance, single-chip analog-to-digital converter (ADC) with ...
refiner168 TI Technology Forum
How to Use an Operational Amplifier
pdf format Chapter 1 Operational Amplifiers Chapter 2 Basic Circuits Chapter 3 Oscillators Chapter 4 Audio Circuits Chapter 5 Filters Chapter 6 Other Circuits Chapter 7 Commonly Used Operational Ampli...
cqzy6666 MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 400  712  1221  1298  472  9  15  25  27  10 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号