15~40W AC-DC Single Output Desktop
Features :
2 pole AC inlet IEC320-C8
Class
power (without earth pin)
Full output 3~48V safety approval
P40B
series
Protections: Short circuit / Overload / Over voltage / Over temp.
Fully enclosed plastic case
Fix switching frequency and regulation
Topology: Top switch circuit
LED indicator for power on
Approvals: UL / CUL / TUV / CB / CE
2 years warranty
SPECIFICATION
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
P40B-0P2J
PSU40B-0
Note.2
3.3V
TUV
Rheinland
Product Safety
geprUfre
Sicherheit
P40B-1P2J
PSU40B-1
5V
5A
0 ~ 5A
25W
50mVp-p
5 ~ 6V
P40B-1-1P2J P40B-2P2J
PSU40B-1-1 PSU40B-2
7.5V
4A
0 ~ 4A
30W
80mVp-p
6 ~ 8V
5.0%
1.0%
5.0%
9V
3.88A
0 ~3.88A
35W
80mVp-p
8 ~ 11V
5.0%
1.0%
4.0%
P40B-3P2J
PSU40B-3
12V
3.33A
0 ~ 3.33A
40W
80mVp-p
11 ~ 13V
4.0%
1.0%
3.0%
P40B-4P2J
PSU40B-4
15V
2.66A
0 ~ 2.66A
40W
100mVp-p
13 ~ 16V
3.0%
1.0%
2.0%
P40B-5P2J
PSU40B-5
18V
2.22A
0 ~ 2.22A
40W
100mVp-p
16 ~ 21V
3.0%
1.0%
2.0%
P40B-6P2J
PSU40B-6
24V
1.66A
0 ~ 1.66A
40W
150mVp-p
21 ~ 27V
3.0%
1.0%
2.0%
P40B-8P2J
PSU40B-8
48V
0.83A
0 ~ 0.83A
40W
150mVp-p
33 ~ 48V
2.0%
1.0%
1.0%
4.54A
0 ~ 4.54A
15W
3 ~ 5V
RIPPLE & NOISE (max.)
Note.3
50mVp-p
VOLTAGE ADJ. RANGE
Fixed output by internal VR
6.0%
VOLTAGE TOLERANCE
Note.4
10%
LINE REGULATION
LOAD REGULATION
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT (max.)
OVERLOAD
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
Note.5
Note.6
1.0%
8.0%
90 ~ 264VAC
47 ~ 63Hz
65%
1A / 100VAC
60A / 230VAC
1.0%
5.0%
SETUP, RISE, HOLD UP TIME
200ms, 50ms, 16ms at full load
135 ~ 370VDC
70%
72%
74%
75%
78%
78%
80%
82%
INPUT
0.25mA / 240VAC
150 ~ 450% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
110 ~ 140% rated output voltage
Protection type : Shut down o/p voltage, re-power on to recover
IC1Tj135
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
0 ~ +40
-20 ~ +85
(Refer to output load derating curve)
, 10 ~ 95% RH
20% ~ 90% RH non-condensing
0.03% / ( 0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL1950, CSA22.2, EN60950-1 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
I/P-O/P:3KVAC
SAFETY &
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
ISOLATION RESISTANCE
EMC
EMI CONDUCTION & RADIATION
Compliance to EN55022(CISPR22) class B
(Note. 7)
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
MTBF
OTHERS
DIMENSION
PACKING
PLUG
CABLE
Compliance to EN61000-4-2,3,4,5,6,11, ENV50204, light industry level, criteria A
500khrs min. MIL-HDBK-217F (25
)
108*67*36mm (L*W*H)
0.3kg; 54pcs / 20kg / CARTON
Standard type P2J: 2.1 * 5.5 * 11mm, center positive for stock; Other type available by customer requested
Standard type see page2 ; Other type available by customer requested
CONNECTOR
NOTE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerence: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 0% to 100% rated load.
7.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:P40B-SPEC 208-05-08