45W Dual Output Switching Power Supply
■
Features :
Universal AC input/Full range
Low leakage current<0.5mA
PD-45
series
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 65KHz
2 years warranty
Bauar t gepruft
Sicherheit
egel ma ge
od
o s
be wac
g
SPECIFICATION
MODEL
OUTPUT NUMBER
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT POWER (max.)
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
INPUT
EFFICIENCY(Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
EMC
(Note 4)
www. tuv.com
ID 2000000000
PD-45A
CH1
5V
3.2A
0.4 ~ 5A
40W
120mVp-p
±7.0%
±2.0%
±4.0%
CH2
12V
2A
0.2 ~ 2.5A
PD-45B
CH1
5V
3.2A
0.4 ~ 5A
44.8W
50mVp-p
CH1:4.75 ~ 5.5V
±4.0%
±1.0%
±3.0%
150mVp-p
±7.0%
±2.0%
±4.0%
CH2
24V
1.2A
0.2 ~ 1.8A
Rated output power for convection; 52W with 18CFM min. Forced air
RIPPLE & NOISE (max.)
Note.2
50mVp-p
CH1:4.75 ~ 5.5V
VOLTAGE TOLERANCE
Note.3
±4.0%
±1.0%
±3.0%
800ms, 20ms at full load
60ms at full load
90 ~ 264VAC
47 ~ 440Hz
77%
1A/115VAC
0.7A/230VAC
COLD START 15A/115VAC
<0.75mA
127 ~370VDC
78%
30A/230VAC
53 ~ 75W rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
5.75 ~ 6.75VDC on CH1
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
-10 ~ +60
℃
(Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-20 ~ +85
℃
, 10 ~ 95% RH
±
0.04%/
℃
(0 ~ 50
℃
) on +5V output
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1,
EAC TP TC 004
approved
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
℃
/ 70% RH
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A, EAC TP TC 020
288.1K hrs min. MIL-HDBK-217F (25
℃
)
127*76*28mm (L*W*H)
0.2Kg; 72pcs/16Kg/1.35CUFT
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
MTBF
OTHERS
NOTE
DIMENSION
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25
℃
of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
5. Mounting holes M1 and M2 should be grounded for EMI purposes.
6. Heat Sink HS1,HS2 can not be shorted.
7. The ambient temperature derating of 3.5
℃
/1000m with fanless models and of 5
℃
/1000m with fan models for operating altitude higher than 2000m(6500ft).
File Name:PD-45-SPEC 2018-01-12