100W Single Output Switching Power Supply
■
Features :
Universal AC input / Full range
RS-100
series
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
All using 105
℃
long life electrolytic capacitors
Withstand 300VAC surge input for 5 second
High operating temperature up to 70
℃
Withstand 5G vibration test
High efficiency, long life and high reliability
3 years warranty
Bauar t gepruft
Sicherheit
egel ma ge
od
o s
be wac
g
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
RS-100-3.3
3.3V
20A
0 ~ 20A
66W
RS-100-5
5V
16A
0 ~ 16A
80W
80mVp-p
4.75 ~ 5.5V
±2.0%
±0.5%
±1.0%
RS-100-12
12V
8.5A
0 ~ 8.5A
102W
120mVp-p
11.4 ~ 13.2V
±1.0%
±0.5%
±0.5%
RS-100-15
15V
7A
0 ~ 7A
105W
120mVp-p
14.25 ~ 16.5V
±1.0%
±0.5%
±0.5%
24V
4.5A
0 ~ 4.5A
108W
120mVp-p
www. tuv.com
ID 2000000000
RS-100-24
RS-100-48
48V
2.3A
0 ~ 2.3A
110.4W
200mVp-p
45.6 ~ 52.8V
±1.0%
±0.5%
±0.5%
RIPPLE & NOISE (max.)
Note.2
80mVp-p
3.2V ~ 3.5V
VOLTAGE TOLERANCE
Note.3
±3.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
(Note 6)
EMC EMISSION
EMC IMMUNITY
MTBF
OTHERS
NOTE
Note.4
±0.5%
Note.5
±2.0%
22.8 ~ 26.4V
±1.0%
±0.5%
±0.5%
500ms, 20ms/230VAC
100ms/230VAC
88 ~ 264VAC
47 ~ 63Hz
74%
77%
1200ms, 30ms/115VAC at full load
18ms/115VAC at full load
125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
81%
82%
84%
84%
2.5A/115VAC
1.5A/230VAC
COLD START 40A/230VAC
<2mA / 240VAC
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
3.8 ~ 4.45V
5.75 ~ 6.75V
13.8 ~ 16.2V
17.25 ~ 20.25V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-25 ~ +70
℃
(Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85
℃
, 10 ~ 95% RH
±
0.03%/
℃
(0 ~ 50
℃
)
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1
,
EAC TP TC 004
approved
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
℃
/ 70% RH
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A, EAC TP TC 020
260.8Khrs min. MIL-HDBK-217F (25
℃
)
159*97*38mm (L*W*H)
0.6Kg; 24pcs/15.4Kg/0.7CUFT
27.6 ~ 32.4V
55.2 ~ 64.8V
DIMENSION
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25
℃
of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
8. The ambient temperature derating of 3.5
℃
/1000m with fanless models and of 5
℃
/1000m with fan models for operating altitude higher than 2000m(6500ft).
File Name:RS-100-SPEC 2018-01-12