EEWORLDEEWORLDEEWORLD

Part Number

Search

RT-85

Description
85W Triple Output Switching Power Supply
Categoryunclassified   
File Size84KB,2 Pages
ManufacturerMEAN WELL
Websitehttp://www.meanwell.com
Download Datasheet Compare View All

RT-85 Online Shopping

Suppliers Part Number Price MOQ In stock  
RT-85 - - View Buy Now

RT-85 Overview

85W Triple Output Switching Power Supply

85W Triple Output Switching Power Supply
R T- 8 5
series
Features :
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
All using 105
long life electrolytic capacitors
Withstand 300VAC surge input for 5 second
High operating temperature up to 70
Withstand 5G vibration test
High efficiency, long life and high reliability
3 years warranty
Bauar t gepruft
Sicherheit
egel ma ge
od
o s
be wac
g
SPECIFICATION
MODEL
OUTPUT NUMBER
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
RT-85A
CH1
5V
8A
Note.6
2 ~ 10A
Note.6
84.5W
www. tuv.com
ID 2000000000
RT-85B
CH2
12V
3.5A
0.3 ~ 4A
CH3
-5V
0.5A
0 ~ 1A
CH1
5V
8A
2 ~ 10A
88W
CH1: 4.75 ~ 5.5V
±2.0%
±5.0%
±0.5%
±1.0%
±1.0%
±3.0%
CH2
12V
3.5A
0.3 ~ 4A
CH3
-12V
0.5A
0 ~ 1A
RT-85C
CH1
5V
7A
2 ~ 10A
87.5W
CH1: 4.75 ~ 5.5V
±2.0%
+3,-7%
±0.5%
±1.0%
±1.0%
±3.0%
CH2
15V
3A
0.3 ~ 4A
CH3
-15V
0.5A
0 ~ 1A
RT-85D
CH1
5V
6A
2 ~ 10A
90W
CH1: 4.75 ~ 5.5V
±2.0%
±5.0%
±0.5%
±1.0%
±1.0%
±3.0%
CH2
24V
2A
CH3
12V
1A
0.3 ~ 2.5A 0.1 ~ 1A
RIPPLE & NOISE (max.)
Note.2
80mVp-p 120mVp-p 100mVp-p 80mVp-p 120mVp-p 120mVp-p 80mVp-p 120mVp-p 120mVp-p 80mVp-p 150mVp-p 120mVp-p
CH1: 4.75 ~ 5.5V
VOLTAGE TOLERANCE
Note.3
±2.0%
±5.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
Note.4
±0.5%
Note.5
±1.0%
±6.0%
±1.0%
±6.0%
±6.0%
±1.0%
±6.0%
±6.0%
±1.0%
±6.0%
±6.0%
±1.0%
±6.0%
±1.0%
±3.0%
500ms, 20ms/230VAC
100ms/230VAC
88 ~ 264VAC
47 ~ 63Hz
76%
1200ms, 30ms/115VAC at full load
18ms/115VAC at full load
125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
76%
77%
79%
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
2.5A/115VAC
1.5A/230VAC
COLD START 40A/230VAC
<2mA / 240VAC
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1: 5.75 ~ 6.75V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-25 ~ +70
(Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85
, 10 ~ 95% RH
±
0.03%/
(0 ~ 50
)on +5V output
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1
,
EAC TP TC 004
approved
I/P-O/P:3KVAC
I/P-FG:2.0KVAC
O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
/ 70% RH
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A, EAC TP TC 020
215Khrs min. MIL-HDBK-217F (25
)
159*97*38mm (L*W*H)
0.6Kg; 24pcs/15.4Kg/0.7CUFT
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
(Note 7)
EMC EMISSION
EMC IMMUNITY
MTBF
OTHERS
DIMENSION
PACKING
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25
of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
6. Each output can work within current range. But total output power can't exceed rated output power.
7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
9. The ambient temperature derating of 3.5
/1000m with fanless models and of 5
/1000m with fan models for operating altitude higher than 2000m(6500ft).
File Name:RT-85-SPEC 2018-01-12

RT-85 Related Products

RT-85 RT-85C
Description 85W Triple Output Switching Power Supply 85W Triple Output Switching Power Supply

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1411  987  143  1157  168  29  20  3  24  4 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号