EEWORLDEEWORLDEEWORLD

Part Number

Search

SPU02L-05

Description
2W DC-DC Unregulated Single Output Converter
CategoryAnalog mixed-signal IC    The signal circuit   
File Size49KB,1 Pages
ManufacturerMEAN WELL
Websitehttp://www.meanwell.com
Environmental Compliance
Download Datasheet Parametric Compare View All

SPU02L-05 Online Shopping

Suppliers Part Number Price MOQ In stock  
SPU02L-05 - - View Buy Now

SPU02L-05 Overview

2W DC-DC Unregulated Single Output Converter

SPU02L-05 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
package instruction,
Reach Compliance Codecompli
Base Number Matches1
2W DC-DC Unregulated Single Output Converter
Features :
3000VDC I/O isolation
Internal SMD technology
Built-in EMI filter
Protection: Short circuit
Cooling by free air convection
Non-conductive plastic case
Single in line package
100% full load burn-in test
Low cost / High reliability
2 years warranty
SPU02
series
SPECIFICATION
ORDER NO.
DC OUTPUT VOLTAGE
CURRENT RANGE
EFFICIENCY (Typ.)
RATED POWER
OUTPUT
SPU02L-05
5V
80 ~ 400mA
77%
2W
79%
77%
SPU02M-05 SPU02N-05
SPU02L-12
12V
33 ~ 167mA
80%
81%
80%
SPU02M-12 SPU02N-12
SPU02L-15
15V
27 ~ 133mA
81%
83%
82%
SPU02M-15 SPU02N-15
RIPPLE & NOISE (max.)
Note.2
100mVp-p
LINE REGULATION
Note.3
±
1.2% for 1% input variation
LOAD REGULATION
VOLTAGE ACCURACY
SWITCHING FREQUENCY
VOLTAGE RANGE
NORMAL VOLTAGE
Note.4
±8.0%
±
2.0%
100KHz min.
4.5 ~ 5.5V
5V
10.8 ~ 13.2V 21.6 ~ 26.4V 4.5 ~ 5.5V
5V
12V
24V
214mA
20mA
107mA
15mA
520mA
60mA
10.8 ~ 13.2V 21.6 ~ 26.4V 4.5 ~ 5.5V
5V
12V
24V
214mA
20mA
107mA
15mA
520mA
60mA
10.8 ~ 13.2V 21.6 ~ 26.4V
12V
24V
214mA
20mA
107mA
15mA
INPUT
INPUT CURRENT
FILTER
PROTECTION
OVERLOAD
Full load 520mA
No load 60mA
Capacitor type
Fuse recommended
Momentary
Protection type : Broken
Momentary
Protection type : Broken
-40 ~ +71
(Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-40 ~ +105
, 10 ~ 95% RH
±
0.03% /
(0 ~ 50
)
10 ~ 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes
I/P-O/P:3KVDC
I/P-O/P: 100M Ohms / 500VDC / 25
/ 70% RH
80pF max.
Compliance to EN55032 Class B, FCC part 15 Class B
Compliance to EN61000-4-2,3,4,5,6,8, light industry level, criteria A
700khrs min. MIL-HDBK-217F(25
)
19.6*7.1*10.2mm or 0.77"*0.28"*0.40" inch (L*W*H)
2.3g
PROTECTION
SHORT CIRCUIT
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
SAFETY &
ISOLATION CAPACITANCE
EMC
EMC EMISSION
EMC IMMUNITY
MTBF
OTHERS
DIMENSION
WEIGHT
Mechanical Specification
19.6 (0.77)
3.81 (0.15)
10.14 (0.40)
Pin Configuration
Unit: mm (inch)
Derating Curve
Pin No.
FRONT VIEW
Output
100
LOAD (%)
1
2
5
7
+Vin
-Vin
-Vout
+Vout
80
0.5 (0.02)
7.1 (0.28)
1 2
5
7
5.08 (0.20)
BOTTOM VIEW
-40
0
25
50 60 71
100
1.2 (0.05)
Ta (
)
NOTE
1.All parameters are specified at normal input, rated load, 25
70% RH ambient.
2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
3.Line regulation is measured from low line to high line at rated load.
4.Load regulation is measured from 20% to 100% rated load.
File Name: SPU02-SPEC 2017-11-16

SPU02L-05 Related Products

SPU02L-05 SPU02 SPU02L-09 SPU02M-09 SPU02N-09
Description 2W DC-DC Unregulated Single Output Converter 2W DC-DC Unregulated Single Output Converter DC DC CONVERTER 9V 2W DC DC CONVERTER DC DC CONVERTER
Using Power Management
Power management allows you to reduce overall power consumption by slowing down workstation activity when the workstation is idle. For more information about power consumption, refer to the HP Worksta...
zbz0529 Power technology
Suggestions on improving the operating functions of the Agilent InfiniVison DSO-X2012A oscilloscope
[i=s]This post was last edited by ylyfxzsx on 2017-9-8 01:45[/i] I bought this oscilloscope for work needs and because I have always had a soft spot for Agilent instruments. Then, when I was using it ...
ylyfxzsx Test/Measurement
How to disable frequency hopping in zstack?
How to disable frequency hopping in zstack?...
ljt8015 RF/Wirelessly
Common problems and myths in water conservancy security monitoring construction
Since the construction area of water conservancy monitoring equipment covers a wide range, some of them are even built in remote mountainous areas and face severe weather such as strong winds and rain...
xyh_521 Industrial Control Electronics
Flash Operation
The specification says that there is a distinction between flash memory initialization and RAM initialization. When initializing the flash controller in the flash memory, there is no need to check the...
jiangwei0802 Microcontroller MCU
Please tell me about the operating system on the router
I would like to ask you: What operating system is running on Huawei or Cisco routers, is it Windows or Linux? Or is it an operating system developed by the company itself?...
河马 Embedded System

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2505  2839  454  2084  1562  51  58  10  42  32 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号