EEWORLDEEWORLDEEWORLD

Part Number

Search

TR-11CX631.2A

Description
UL1077 Recognized Supplementary Protector/ Circuit Breaker for Equipment
File Size470KB,3 Pages
ManufacturerAltech
Websitehttp://www.altechcorp.com/
Download Datasheet Compare View All

TR-11CX631.2A Overview

UL1077 Recognized Supplementary Protector/ Circuit Breaker for Equipment

Altech UL1077
TR11 Series
E209569
up to 12 Amps
UL1077 Recognized
Supplementary Protector/
Circuit Breaker for Equipment
Applications:
Protection of single phase Motors, Transformers,
UPS, Power strips, Solenoids etc., against
damage due to overcurrent conditions.
Current Rating
Rated Voltage
Initial insulation resistance
Dielectric strength
Overload Switching Capacity
Maximum Breaking Capacity
Power Loss
Operating Temperature
Operational Life at 2xIn
Limited short circuit current
Terminals
Applicable Standards
Approvals
Accessories
0.5 -16.0A
240V AC, 50/60Hz,
32V DC / 24V DC (VDE)
(As per EN 60934)
> 100 M ohms.
(As per EN 60934)
1.5 KV for One minute.
6 I
n
~ up to 9.0A
(As per EN 60934)
4 I
n
- up to 12.0A
60A Max. ~ from 10.0A to 12.0A
60A Max. - from 10.0A to 12.0A
8x I
n
for <6.0A
60A MAX. for > 6.0A
1 - 2 Watts
Maximum 60°C Ambient
1000 Cycles
1000 Amps PC 1
Operating
Characteristic
(min) 60
30
20
10
5
1
(S) 50
20
10
5
2
1
Trip time
0.5
0.2
0.1
1.05 1.32
2
3
4 5
8 10
0.25” Quick connect
EN 60934, CSA 22.2 No. 235, UL-1077
up to 16.0 A
upto 12.0A
Dust Cover, DC-TR11 C (see page 14)
Time Current Characteristics:
The standard characteristic is valid for ambient temperatures of
+23°C. If the device is to be used in an ambient temperature other
than +23°C, allowances must be made when selecting the current
rating according to the following guidelines:
Ambient temp. °C
Correction Factor
Example :
-20
-5
0
+10
0.96
:
:
:
:
:
+20
1
+30
1.05
+40
1.12
+50
1.2
+60
1.3
0.8 0.88 0.9
Normal Continuous Current
Ambient Temperature
Correction Factor
Recommended Current Rating
Select the nearest
1.8A
40°C
1.12
1.8 x 1.12 = 2.016
2.0A
Multiple of Rated Current
Rated current
Ambient
Temperature
<6A
>6A
23°C
16
Altech Corp.
®
• 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com

TR-11CX631.2A Related Products

TR-11CX631.2A TR-11CX630.5A TR-11CX630.9A
Description UL1077 Recognized Supplementary Protector/ Circuit Breaker for Equipment UL1077 Recognized Supplementary Protector/ Circuit Breaker for Equipment UL1077 Recognized Supplementary Protector/ Circuit Breaker for Equipment

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1244  1719  2580  940  787  26  35  52  19  16 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号