EEWORLDEEWORLDEEWORLD

Part Number

Search

IWS548Y3V-I

Description
1-OUTPUT 10W DC-DC REG PWR SUPPLY MODULE
CategoryPower/power management    The power supply circuit   
File Size104KB,3 Pages
ManufacturerBel Fuse
Download Datasheet Parametric View All

IWS548Y3V-I Overview

1-OUTPUT 10W DC-DC REG PWR SUPPLY MODULE

IWS548Y3V-I Parametric

Parameter NameAttribute value
Brand NamePower-One
package instruction,
Reach Compliance Codeunknown
Analog Integrated Circuits - Other TypesDC-DC REGULATED POWER SUPPLY MODULE
Maximum input voltage9 V
Minimum input voltage4.5 V
Nominal input voltage5 V
JESD-30 codeR-XDMA-P4
Number of functions1
Output times1
Number of terminals4
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
Maximum output voltage48.48 V
Minimum output voltage47.52 V
Nominal output voltage48 V
Package body materialUNSPECIFIED
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Certification statusNot Qualified
surface mountNO
technologyHYBRID
Temperature levelINDUSTRIAL
Terminal formPIN/PEG
Terminal locationDUAL
Maximum total power output10 W
Fine-tuning/adjustable outputNO
Base Number Matches1
IWS SERIES - 10 WATT
DESCRIPTION
IWS DC/DC converters offer excellent regulation and
isolation in an industry-standard package. Available in
several input versions, the IWS is perfect for industrial,
datacom, or telecom applications. The IWS features short
circuit protection and 500 VDC isolation. Please see the
IWD series for dual-output applications.
FEATURES
• Industry-Standard Package
• Industry-Standard Pinout
• 85°C Case Operation
• Short-Circuit Protection
• 5, 12, 24, and 48V
Input Versions
• Input Pi Filter and
6-Sided Shielding
• Regulated Outputs
• 500V Isolation
Efficiency vs. Load (5V Input)
90
85
EFFICIENCY %
TECHNICAL SPECIFICATIONS
Input
Voltage Range
5 VDC Nominal
12 VDC Nominal
24 VDC Nominal
48 VDC Nominal
Reflected Ripple
Reverse Input Current
4.5 - 9 VDC
9 - 18 VDC
18 - 36 VDC
36 - 72 VDC
20% Iin Max.
100% Iin Max.
80
IWS515
IWS548
75
70
10
20
30
40
50
60
70
80
90
100
LOAD %
Efficiency vs. Load (12V Input)
90
85
80
EFFICIENCY %
Output
Setpoint accuracy
Line regulation Vin Min. - Vin Max., Iout Rated
Load regulation Iout Min. - Iout Max., Vin Nom.
Minimum output current
Dynamic regulation, loadstep
Pk deviation
Settling time
Temperature coefficient
Ripple and noise, 20 MHz BW
Short-circuit protection 1
Current Limit
±1%
±0.5% Vout
±1.0% Vout
10 % Iout Rated
25% Iout
1% Vout
500 ms
0.02%/°C
1% Vout Nom.
Continuous
130%
75
70
65
60
55
50
10
20
30
40
50
60
70
80
90
100
LOAD %
-1205
-1212
-1215
General
Switching Frequency
Isolation
Input - Output
500 VDC
500 VDC
500 VDC
109 Ohms
-25 to +85°C
-40 to +85°C
-40 to +125°C
95%
5 g, 10 - 55 Hz
UL, cUL, TUV
1.4 oz
Input - Case
Output - Case
Isolation Resistance - Input to Output
Standard Case Operating Range
Industrial Range (add -I to p/n)
Storage Range
Humidity Max., Non-Condensing
Vibration, 3 Axes, 5 Min Each
Safety
Weight (approx.)
300 kHz
Notes
1 Continuous short-circuit protection is provided. Long-term continuous
operation in this mode is not recommended. Converter will auto-restart
once fault has been removed.
Specifications typically at 25°C, normal line, and full load, unless
otherwise stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with
commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model. Please
consult factory for specific model information.
REV. 12/01
1
2005 National Electronics Competition Outstanding Papers
It has great reference value. It would be a pity not to read it....
cgp429125159 PCB Design
How to use the IO port of stm32 as event input
The IO port of tm32 is handled by the interrupt function as interrupt input, and who handles it as event input? Where does the pulse generated by the event go? I hope an expert can give me some advice...
w_d_j stm32/stm8
What is the main frequency band currently used by ZIGBEE in Europe and the United States?
Is the frequency band currently used by ZIGBEE in Europe and America 868/915 or 2400? How is the market situation of 2.4G ZIGBEE in Europe and America? Thanks....
jixuanmu RF/Wirelessly
The BLE course in-class exam is now online. Test your knowledge of BLE!
[font=微软雅黑][size=3]Do you remember that our university launched a BLE course before? [/size][/font] [font=微软雅黑][size=3]If you remember it or not, please click here: [/size][/font][url=https://www.eewo...
linjiang Wireless Connectivity
【Discussion】Bidirectional thyristor is in working state throughout the entire cycle in AC
How to avoid the zero-crossing cutoff of the bidirectional thyristor if you want the bidirectional thyristor to be in working state during the whole cycle of AC power?[[i]This post was last edited by ...
LINGON 51mcu
Micro printer instructions and procedures (adjusted)
[i=s]This post was last edited by paulhyde on 2014-9-15 09:38[/i] Many competition questions require you to print out your results. Even if it is not required, printing it out will add a lot of color ...
guoguo8034 Electronics Design Contest

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 240  1421  1880  1292  1377  5  29  38  27  28 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号