EEWORLDEEWORLDEEWORLD

Part Number

Search

SIL842170

Description
AC Semiconductor Contactor pitch 22,5mm compact size and DIN rail mounting.
File Size247KB,4 Pages
ManufacturerCELDUC
Websitehttp://www.celduc-relais.com/uk/index.asp
Download Datasheet View All

SIL842170 Overview

AC Semiconductor Contactor pitch 22,5mm compact size and DIN rail mounting.

celpac®
AC Semiconductor Contactor
pitch 22,5mm
compact size and DIN rail
mounting.
t
Ready to use Single-Phase Relay: " Install it & Forget it!"
t
Zero cross model :
12-275VAC 25A
alternistor on
output.
I
2
t value > 312A
2
s .
t
Large control range :
3-32VDC
with an input
current < 10 mA on all the range.
Green LED visualization on the input.
t
Very high immunity : Voltage protection on output
and input- 4kV according IEC61000-4-4 & 5
t
IP20 housing
t
Low leakage current (<1mA) and low zero cross
voltage ( <10V)
t
Mounting and dismounting on DIN rail without any
tool or directly mountable on panel.
t
Designed in conformity with EN60947-4-3
(IEC947-4-3)-UL-cUL
Dimensions :
S/CLP/SIL842170/B/21/04/2004
page 1 / 4GB
SIL842170
Output : 12-275VAC 25A(*)
Input : 3-32VDC/I<10mA
(*) see conditions (thermal curve page 3)
20A
230VAC 50hz
Protection
L1
SSR
Typical
application:
4kW resistor
(AC-51 load)
on 230 VAC
T1
A2 A1
-
+
Control
load
LOAD
Proud to serve you
All technical caracteristics are subject to change without previous notice.
Caractéristiques sujettes à modifications sans préavis.
r
celduc
e
l
a
i
s
A quick way to find TI devices
[i=s]This post was last edited by dontium on 2014-12-30 20:36[/i]TI's website is well designed and it is very convenient to search for components. -------This is all due to the activities and question...
dontium Analogue and Mixed Signal
Please advise on the release script file settings under IAR
My project program was modified from IAR, which only has Debug scripts. I added a Release and used the debug in flash script, but found that the length of the generated code was the same as that under...
logic1231 stm32/stm8
Can I ask for the input method registration form?
I would like to ask about the input method registry. Why are some input method registries in the following format: [HKEY_LOCAL_MACHINE\System\CurrentControlSet\Control\Layouts\e0010804] "Layout Text"=...
wenwen223 Embedded System
Altium Designer 18.1.5 How to change Mechanical1 back to Keepout layer
I have to do it manually inside, which is a bit tricky. Please help me....
btty038 PCB Design
How to determine whether the received data is a command or data when FPGA controls the data transmission and reception of the network card chip
I use FPGA to control the network card chip to make a data transmission and reception device, but how can I make FPGA start sending data? Specifically, FPGA starts sending data when it receives a comm...
yyj807 FPGA/CPLD
Modify the files extracted from DSP56F803
The program read from DSP56F803BU80E is saved in BIN or S19 format. Now I want to modify some character data, but I can't find the check bit in the Hex editor. After modifying it, it can't be used whe...
56F803 NXP MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1687  1998  409  1139  1862  34  41  9  23  38 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号