EEWORLDEEWORLDEEWORLD

Part Number

Search

T-20201

Description
Multi-Purpose Transformers with optional Electrostatic Sheilding
CategoryPower management    transformer   
File Size34KB,2 Pages
ManufacturerRhombus Industries, Inc.
Websitehttp://www.rhombus-ind.com/
Download Datasheet Parametric View All

T-20201 Overview

Multi-Purpose Transformers with optional Electrostatic Sheilding

T-20201 Parametric

Parameter NameAttribute value
MakerRhombus Industries, Inc.
Reach Compliance Codeunknow
ECCN codeEAR99
applicationGENERAL PURPOSE
ET product minimum value46 V-us
high10.16 mm
Insulation voltage700 V
length16.51 mm
Manufacturer's serial numberT-20201
Installation featuresTHROUGH HOLE MOUNTED
Number of functions1
physical sizeL16.51XB11.25XH10.16 (mm)
Primary inductance500 µH
Maximum pulse rise time8 ns
surface mountNO
Transformer typeDATACOM TRANSFORMER
Turns ratio (Np:Ns)1:1
width11.25 mm
Multi-Purpose Transformers
with optional
Electrostatic Sheilding
High Flux Density
Isolation 700V
RMS
minimum
300V Peak Pulse Voltage
Electrical Specifications at 25
O
C
Turns
Ratio
+
5%
1:1
1:1
1:1
1:1
1:1
1:1
1:2
1:2
1:2
1:3
1:4
1:1:1
1:1:1
1:1:1
1:1:1
1:1:1
2:1:1
2:1:1
4:1:2
4:1:2
4:1:4
4:1
8:1
1:2:1
1:4:1
OCL
+
20%
( mH )
0.06
0.5
1.3
2.5
5.0
20.0
0.5
1.0
6.0
2.5
2.5
0.06
0.5
1.3
5.0
10.0
0.5
10.0
5.0
10.0
3.0
20.0
2.5
2.3
0.8
E-T
Rise
Pri / Sec
min. Time max C
W/W
max
( V-µS )
( ns )
( pF )
34.0
46.0
84.0
126.0
175.0
250.0
46.0
70.0
175.0
140.0
140.0
34.0
46.0
91.0
196.0
245.0
46.0
210.0
190.0
182.0
160.0
420.0
112.0
140.0
63.0
7.0
8.0
30.0
30.0
80.0
80.0
40.0
50.0
100.0
80.0
170.0
7.0
9.0
30.0
70.0
100.0
30.0
40.0
100.0
90.0
80.0
100.0
140.0
70.0
180.0
24.0
26.0
40.0
39.0
38.0
87.0
37.0
36.0
36.0
83.0
95.0
23.0
27.0
38.0
35.0
36.0
29.0
42.0
51.0
38.0
24.0
75.0
16.0
44.0
39.0
L
L
max.
(
µH
)
1.2
1.7
3.0
4.0
14.0
6.9
1.6
2.2
15.0
2.7
3.0
1.3
2.0
3.2
13.0
14.0
1.5
13.0
8.4
13.0
12.0
13.0
16.0
4.2
2.0
Pri. DCR Sec. DCR Ter. DCR
max.
max.
max.
(
)
(
)
(
)
0.7
1.3
3.6
5.8
9.8
27.0
0.9
1.4
5.0
6.5
12.0
0.6
1.4
3.6
8.8
14.0
1.5
7.8
9.3
7.6
7.0
36.0
5.6
6.0
1.0
0.7
1.4
3.8
6.1
11.0
28.0
6.3
3.1
24.0
19.0
45.0
0.6
1.5
3.8
9.6
15.0
0.3
4.2
0.6
0.6
0.5
2.2
0.5
13.0
17.0
---
---
---
---
---
---
---
---
---
---
---
0.6
1.6
3.9
11.0
16.0
0.3
4.4
4.9
4.4
7.8
---
---
6.8
1.1
Schematic Diagrams
2 Windings
Part No.
T-20200
T-20201
T-20202
T-20203
T-20204
T-20205
T-20206
T-20207
T-20208
T-20209
T-20210
T-20211
T-20212
T-20213
T-20214
T-20215
T-20216
T-20217
T-20219
T-20220
T-20223
T-20224
T-20225
T-20226
T-20227
5
Pri.
6
4
2
Sec.
3
1
3 Windings
5
Ter.
6
4
Sec.
3
1
2
Pri.
2 Windings & Shield
5
Sec.
6
4
2
Pri.
3
1
.650
(16.51)
MAX.
.443
(11.25)
MAX.
.400
(10.16)
MAX.
.425
(10.80)
.500
(12.70)
.125
(3.18)
.500
(12.70)
MIN.
.026 DIA.
(0.66)
TYP.
.150
(3.81)
TYP.
Specifications subject to change without notice.
For other values & Custom Designs, contact factory.
BT6 - 2/99
Rhombus
Industries Inc.
www.rhombus-ind.com
15801 Chemical Lane, Huntington Beach, CA 92649-1595
Tel: (714) 898-0960
Fax: (714) 896-0971
It's hard to survive
It's really hard to find a job, especially for my special situation. I'm a troublemaker in school, I don't have a scholarship, I'm not in the student union, and I don't have a high degree. Even if I h...
cl17726 Talking
EEWORLD DIY-Make an environmental parameter storage system
I'd like to take this opportunity to share a recent work I made. Function: Collect sensor data and store it. Hardware: Main control: Arduino development board. Sensors: temperature sensor DHT22, PM2.5...
sanhuasr DIY/Open Source Hardware
Participate in MSP430F5529 training, gain knowledge, free gifts, super low group, grab the building! (The list of winners of the fifth phase has been announced)
Participate in TI MSP430F5529 training (learning link: [url=https://www.eeworld.com.cn/training/2013/0222/movie_109.html]https://www.eeworld.com.cn/training/2013/0222/movie_109.html[/url]) [b][font=微软...
EEWORLD社区 Microcontroller MCU
f769 review basic driver chapter - general timer
From the datasheet of f769, we know that there are 15 timers. Among them, timer2, 3, 4, and 5 are general timers. The detailed classification is 16-bit (TIM3, TIM4) or 32-bit (TIM2 and TIM5). This pos...
star_66666 stm32/stm8
BMW original fault detector (GT1) maintenance
A friend of mine has a broken GT1. It started with a power supply failure because a gong cap on the wireless network card socket fell off, shorting something and burning the 3.3V power supply circuit....
qs7779 Automotive Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2540  12  2226  361  2056  52  1  45  8  42 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号