Common Mode Choke
Turns Ratio
Parameter
Inductance
(1)
DCR (1-2) or (4-3)
Leakage Inductance
(1)
1:1
Min.
Typ.
Max.
Units
Materials used in construction of this
component meet or exceed UL Class F (155
o
C)
11.0
1.45
165
(1)
mH
Ω
µH
pF
VDC
Flammability: Materials used in the
production of these units meet requirements
of UL94-VO and IEC 695-2-2 needle flame test.
Schematic
Diagram
Interwinding Capacitance
Breakdown Voltage
Current
SRF
5.00
1500
0.250
490
1
4
Amp
kHz
1. tested at 1 kHz and 100mV
RMS
2
3
.630
(16.0)
MAX
.420
(10.6)
TYP
.66
(16.70)
MAX
.495
(12.60)
MAX.
.16
(4.0)
TYP.
.27
(7.0)
1
2
.025
(0.65)
DIA.
Physical Dimensions
inches (mm)
.31
(8.0)
.50
(12.7)
TYP
4
3
RHOMBUS P/N:
L-299
CUST P/N:
NAME:
DATE:
2/26/98
SHEET:
1 OF 1
Rhombus
Industries Inc.
Transformers & Magnetic Products
www.rhombus-ind.com
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
FAX: (714) 896-0971