Snap Acting/Limit Switch, SPST, Momentary, 9.7mm, Quick Connect/solder Terminal, Long Hinge Lever Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size162KB,18 Pages
ManufacturerPanasonic
Websitehttp://www.panasonic.co.jp/semicon/e-index.html
Environmental Compliance
Download Datasheet Parametric View All

AH765358F Overview

Snap Acting/Limit Switch, SPST, Momentary, 9.7mm, Quick Connect/solder Terminal, Long Hinge Lever Actuator, Panel Mount

AH765358F Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator stroke9.7 mm
Actuator typeLONG HINGE LEVER
body width10.3 mm
body height16.1 mm
Body length or diameter27.8 mm
Electrical life100000 Cycle(s)
JESD-609 codee4
Manufacturer's serial numberAH765
Installation featuresPANEL MOUNT
Maximum operating force0.59 N
Maximum operating temperature120 °C
Minimum operating temperature-25 °C
Maximum pre-travel7.5 mm
surface mountNO
Switch actionMOMENTARY
switch functionSPST
Switch typeSNAP ACTING/LIMIT SWITCH
Terminal surfaceSilver (Ag)
Termination typeQUICK CONNECT/SOLDER
Base Number Matches1
AH7
VERSITILE
HIGH PERFORMANCE
MINIATURE SWITCHES
FEATURES
• Extra long-life spring mechanism
—More than 10
7
mechanical operations,
10
5
electrical
• High contact rating of 15 Amps with
an operating force of only 200 g
• Safety insulation guard types
available
• Available in a wide operating force
and capacity range
• UL/CSA/VDE/SEMKO approved
AH7 (NV)
SWITCHES
TYPICAL
APPLICATIONS
• Home appliances
• Vending machines
• Amusement and communication
equipment
• Copiers
• General industrial machines
ORDERING INFORMATION
Ex. AH7
Type of
switch
NV switch
Contact
arrangement
Terminal
Actuators
0: Pin plunger
1: Short hinge
lever
2: Hinge lever
3: Long hinge
lever
4: Simulated
roller lever
5: Short roller
lever
6: Roller lever
Operating force
by pin plunger
(max.)
∗1
Agency standard
9: UL/CSA 6
×
10
3
rated
8: VDE/SEMKO
(VDE is not available for
Side COM terminal SPDT
and Side COM terminal
SPST-NO type.)
Contact
F: Cadmium free
(F is required only for
silver alloy contact
type. F is not required
for gold clad contact
type as it is originally
cadmium free.)
1: Bottom COM
2: Solder terminal
terminal SPDT
without guard
2: Bottom COM
5: .187 Quick-connect/
terminal SPST-NC
solder terminal
3: Bottom COM
without guard
terminal SPST-NO 8: .250 Quick-connect
4: Side COM
terminal
terminal SPDT
5: Side COM
terminal SPST-NC
6: Side COM
terminal SPST-NO
Type
Ag alloy contact
Au clad contact
Ag alloy contact
Au clad contact
∗1
.187 Quick connect/solder terminal
Solder terminal
.250 Quick connect terminal
.187 Quick connect/solder terminal
.187 Quick connect/solder terminal
Solder terminal
.250 Quick connect terminal
.187 Quick connect/solder terminal
0.49N 0.98N 1.96N 2.94N 3.92N
356
456
356
456
555
655
755
362
462
562
360
460
360
460
5
6
7
361
461
561
Heat Resistant type
Standard type
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
Infrared wireless communication
I made a pair of triode-driven infrared transceiver circuits, but the transmitting tube is distorted and the receiving tube cannot find the signal. Why is this? Can the triode-driven infrared transcei...
Alexline Analog electronics
How to avoid PCB electromagnetic interference in switching power supply design
In any switching power supply design, the physical design of the PCB board is the last link. If the design method is not appropriate, the PCB may radiate too much electromagnetic interference, causing...
捷配pcb打样工厂 Energy Infrastructure?
[MSP430 compiler usage experience] Several common settings for CCS code editing
[i=s]This post was last edited by Rufer on 2014-7-29 14:48[/i] This is my first post. I would like to share some CCS code editing settings that I find commonly used. 1. Code folding When the code is v...
Rufer Microcontroller MCU
Green hills compiler, if you need it, please contact me
Email: liuzhigang@hisineon.com[/size][/font][/backcolor][/color] :)...
liu0528 Automotive Electronics
[Help] Is it not necessary to add gel files to a new project in ccs5?
I downloaded the TI example and opened it with CCS5. Under the project file, I carefully checked every file and found that there was no gel file. The textbooks I have are for CCS3.3. When creating a n...
jonny0811 Microcontroller MCU
Send me a dictionary for engineers (can only be used on computers)
My English is not very good, so in order to understand various technical materials, I found a dictionary specially for engineers on the Internet. I think the vocabulary is quite comprehensive, and if ...
changwanyang MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2385  1488  772  310  2257  49  30  16  7  46 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号