EEWORLDEEWORLDEEWORLD

Part Number

Search

SV-MWS

Description
Graphical Monitoring Software and Interface Hardware System
File Size82KB,2 Pages
ManufacturerGamewell-FCI ( Honeywell )
Websitehttp://www.gamewell-fci.com
Download Datasheet Compare View All

SV-MWS Overview

Graphical Monitoring Software and Interface Hardware System

600 Series
SmartView™
Description
SmartView™ is a dynamic, feature-rich, graphical fire
alarm monitoring software and interface hardware system
for the Gamewell-FCI IdentiFlex 600 Series of addressable
fire alarm control panels.
Gamewell-FCI’s SmartView™ system includes worksta-
tion software — a Microsoft
®
Windows
®
2000-based graph-
ical user interface. SmartView
®
’s software is designed to be
easy to configure and simple to operate. SmartView
®
pre-
sents information through a graphical menu system and
dynamic color display while operating over a high-speed
Ethernet LAN/WAN or single-user network.
Similar to a website, the menu pages feature user-defined
“hot spots” that either launch a task-specific application or
direct users to another menu page. The system utilizes
custom fire alarm icons to display point-specific alarm infor-
mation. Each alarm event is displayed on a color-coded
alarm display, or with its floor plan pinpointing the exact
location of the alarm. Point-specific user instructions can
also be displayed. All events and user actions are logged
for creating user-selected customized reports. To enhance
user accessibility, event information can also be broadcast
to pagers or emailed via an optional Internet connection.
SmartView™ can monitor an individual IdentiFlex 600
Series addressable fire alarm panel, or an entire
SmartNet™/SmartLink™ network. The SmartView™ sys-
tem supports up to three SmartView™ workstations as
standard; for systems that require four or more worksta-
tions, please consult the factory. Included with each unit of
SmartView™ software is a net communications central pro-
cessing unit with 8 MB DRAM, 4 MB flash, a math copro-
cessor, communication ports, Gamewell-FCI 600 Series
fire alarm panel interface, and power supply.
Graphical Monitoring Software and
Interface Hardware System
Features
SmartView
• Fire alarm monitoring software operating on Windows
®
2000/XP Professional operating system software.
• Compatible with all Gamewell-FCI IdentiFlex 600 Series
fire alarm panels.
• Ethernet TCP/IP net controller.
• High-speed networking.
• Power supply with UPS battery backup.
• SQL database.
• Supports up to three workstations standard with P/N
SV-MWS.
• SmartLink™ peer-to-peer compatible.
• Fully supervised.
• NetController features flash memory for easy on-line
software updates.
• Optional Internet connection.
• Paging and email compatible.
• Easy configuration.
• Familiar interface similar to Windows
®
Explorer.
• Event logs with modifiable “listviews” for customized
reports.
• Select event-specific icons.
• Color-coded alarm bar and Customize graphics.
• Display multiple floor plans and user instructions.
• Multiple workstation support.
Microsoft
®
Windows
®
is a registered trademark of Microsoft
®
Corporation.
SmartView™, SmartNet™ and SmartLink™ are trademarks of Honeywell International Inc.
GAMEWELL-FCI
Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use.
©2007 Honeywell International Inc. All rights reserved.
www.gamewell-fci.com
CS-2150 Rev. A page 1 of 2
12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118
g2150scl.jpg

SV-MWS Related Products

SV-MWS SV-MWOS SV-NC-F SV-SWS
Description Graphical Monitoring Software and Interface Hardware System Graphical Monitoring Software and Interface Hardware System Graphical Monitoring Software and Interface Hardware System Graphical Monitoring Software and Interface Hardware System
My LCD is Hansheng 19264-6, the driver chip is ks0108, I wrote a driver, why can't it be driven?
Below is my program, which is driven by STC52RC. The hardware has been checked many times and is absolutely correct. Could anyone help me see if there is a problem with my program that cannot be displ...
chenyi9258 Embedded System
USB port wiring diagram (headphones + software download + headphone + data cable + FM)...
USB port wiring diagram (headphones + software download + headphone + data cable + FM)......
simonprince Analog electronics
Introduction to the application fields of common displacement sensors
Introduction to the application fields of common displacement sensors   1. Application fields of magnetostrictive displacement sensor   1. Product features of magnetostrictive displacement sensor   * ...
sairvee Sensor
Xilinx ISE prompts that the Number of bonded IOBs has been exceeded. What does this mean?
Device Utilization Summary (estimated values) [-] Logic Utilization Used Available Utilization Number of Slice Registers 797 106400 0% Number of Slice LUTs 1763 53200 3% Number of fully used LUT-FF pa...
koanzhongxue FPGA/CPLD
I urgently hope that there will be a Chinese version of the STM firmware library user manual!
Apart from the data sheet, this is the one that most needs Chinese version. I hope you can consider it....
james2451 stm32/stm8
Is there anyone who develops digital photo frame software?
Is there anyone who develops digital photo frame software? I have a job and I want to find someone to do it. QQ: 3836435...
djxgirl Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2768  1861  1774  685  1042  56  38  36  14  21 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号