AC-DC Power Factor Correction Module, 1 Output, 100W, Hybrid, METAL, CASE S02, MODULE
CategoryPower/power management    The power supply circuit   
File Size599KB,27 Pages
ManufacturerBel Fuse
Download Datasheet Parametric View All

LS4001-7RD6B1 Overview

AC-DC Power Factor Correction Module, 1 Output, 100W, Hybrid, METAL, CASE S02, MODULE

LS4001-7RD6B1 Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
package instruction,
Reach Compliance Codecompliant
ECCN codeEAR99
Analog Integrated Circuits - Other TypesAC-DC POWER FACTOR CORRECTION MODULE
Maximum input voltage255 V
Minimum input voltage85 V
Nominal input voltage230 V
JESD-30 codeR-MXMA-X
JESD-609 codee0
Number of functions1
Output times1
Maximum operating temperature71 °C
Minimum operating temperature-25 °C
Maximum output voltage5.61 V
Minimum output voltage
Nominal output voltage5.1 V
Package body materialMETAL
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
technologyHYBRID
Temperature levelCOMMERCIAL EXTENDED
Terminal surfaceTIN LEAD
Terminal formUNSPECIFIED
Terminal locationUNSPECIFIED
Maximum time at peak reflow temperatureNOT SPECIFIED
Maximum total power output100 W
Fine-tuning/adjustable outputYES
Base Number Matches1
Cassette Style
100 Watt AC-DC Converters
S Series PFC
100 Watt AC-DC Converters with PFC
Input voltage range from 85...264 V AC
1 or 2 isolated outputs up to 48 V DC
4 kV AC I/O electric strength test voltage
Universal input voltage range
Power factor
>0.95,
harmonics
<IEC/EN
61000-3-2
Input over- and undervoltage lock-out
Efficient input filter and built-in surge and transient
suppression circuitry
Fully isolated outputs
Outputs overload, open- and short-circuit proof
No derating over entire operating temperature range
Safety according to IEC/EN 60950
LGA
S Series
111
4.4"
3U
60
2.4"
12 TE
168
6.6"
Summary
The S 4000/S 5000 series of AC-DC converters represents
a flexible range of power supplies for use in advanced elec-
tronic systems. Features include full power factor correc-
tion, high efficiency, high reliability, low output voltage noise
and excellent dynamic response to load/line changes.
The converter inputs are protected against surges and tran-
sients occurring at the source lines. An input over- and
undervoltage lock-out circuitry disables the outputs if the
input voltage is outside the specified range. Inrush current
limitation is included preventing circuit breakers and fuses
from being damaged at switch-on.
All outputs are overload, open- and short-circuit proof and
are protected against overvoltages by means of a built-in
suppressor diode. The outputs can be inhibited by a logic
signal applied to the connector pin 18 (i). If the inhibit func-
tion is not used pin 18 must be connected to pin 14 to en-
able the outputs.
LED indicators display the status of the converter and allow
visual monitoring of the system at any time.
Full input to output, input to case, output to case and output
to output isolation is provided. The modules are designed
and built according to the international safety standards
IEC/EN 60950 and have been approved by the safety
agencies LGA (Germany) and UL (USA). The UL Mark for
Canada has been officially recognized by regulatory au-
thorities in provinces across Canada.
The case design allows operation at nominal load up to
71°C in a free air ambient temperature. If forced cooling is
provided, the ambient temperature may exceed 71°C but
the case temperature must remain below 95°C under all
conditions.
A temperature sensor generates an inhibit signal which
disables the outputs if the case temperature
T
C
exceeds
the limit. The outputs are automatically re-enabled when
the temperature drops below the limit.
Various options are available to adapt the converters to in-
dividual applications.
The modules may either be plugged into 19" rack systems
according to DIN 41494, or be chassis mounted.
Important:
These products are intended to replace the LS 1000 and
LS 2000 in order to comply with IEC/EN 61000-3-2.
Table of Contents
Page
Page
Electromagnetic Compatibility (EMC) ............................ 15
Immunity to Environmental Conditions ........................... 17
Mechanical Data ............................................................ 18
Safety and Installation Instructions ................................ 19
Description of Options .................................................... 22
Accessories .................................................................... 27
Summary .......................................................................... 1
Type Survey and Key Data .............................................. 2
Type Key .......................................................................... 2
Functional Description ...................................................... 3
Electrical Input Data ......................................................... 4
Electrical Output Data ...................................................... 6
Auxiliary Functions ......................................................... 11
Edition 01/01.2001
1/27
Modeling and simulation of air suspension vehicle based on virtual technology
A car is a complex multi-degree-of-freedom vibration system. The key to quantitatively analyzing and evaluating ride comfort lies in building an accurate dynamic model. An accurate dynamic model can h...
frozenviolet Automotive Electronics
6V pulse solenoid valve drive circuit difficulty voltage reversal
Two lead wires are connected to the two stages of the solenoid valve. The working principle of the pulse solenoid valve: briefly give positive 5V to conduct, then cut off the power, and keep the condu...
lwfalbb Renesas Electronics MCUs
Deceptive Camera (Photos)
Compared with women, men are even less reliable. Men are geniuses at lying, and they usually lie without changing their expressions or hearts. The latest survey also proves this point: on average, men...
sunhope Talking
Trends in building automation: Connected sensors optimize user experience
[align=left][color=#000] In the second part of this blog series, I will explore the second trend in wireless sensor networks for building automation - security and reliability. To recap, the four main...
maylove Analogue and Mixed Signal
All received
I received the touchpad too!...
kouyu Microcontroller MCU
Common electronic component terms and translations
Common electronic component terms and translations Author:admin Date:2006-08-23 Crystal and carbon materials, general electronic and electrical components (a total of 161 product/service names) Serial...
fighting Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1065  2153  823  609  2443  22  44  17  13  50 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号