EEWORLDEEWORLDEEWORLD

Part Number

Search

LES010ZE-193H

Description
DC-DC Regulated Power Supply Module, 1 Output, 15W, Hybrid
CategoryPower/power management    The power supply circuit   
File Size83KB,3 Pages
ManufacturerBel Fuse
Download Datasheet Parametric View All

LES010ZE-193H Overview

DC-DC Regulated Power Supply Module, 1 Output, 15W, Hybrid

LES010ZE-193H Parametric

Parameter NameAttribute value
Brand NamePower-One
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
package instruction,
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresSETPOINT ACCURACY: +/-1%
Analog Integrated Circuits - Other TypesDC-DC REGULATED POWER SUPPLY MODULE
Maximum input voltage75 V
Minimum input voltage36 V
Nominal input voltage48 V
JESD-30 codeR-XDMA-P5
JESD-609 codee0
Maximum load regulation0.5%
Number of functions1
Output times1
Number of terminals5
Maximum operating temperature100 °C
Minimum operating temperature-40 °C
Maximum output voltage3.63 V
Minimum output voltage2.97 V
Nominal output voltage3.3 V
Package body materialUNSPECIFIED
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
technologyHYBRID
Temperature levelINDUSTRIAL
Terminal surfaceTIN LEAD
Terminal formPIN/PEG
Terminal locationDUAL
Maximum time at peak reflow temperatureNOT SPECIFIED
Maximum total power output15 W
Fine-tuning/adjustable outputYES
Base Number Matches1
LES DC/DC Series Data Sheet
Description
LES DC/DC converters provide up to 15 watts of output
power in an industry-standard package and footprint. With
a maximum case temperature of 100°C, the LES is well
suited for the most demanding telecom, networking, and
industrial applications. The LES features 1500VDC
isolation, short circuit protection, and six-sided shielding.
The LES is available with optional enable and voltage trim
pins. Please see the IAD Series for dual output
applications.
Features
Industry Standard
Package
Industry Standard Pinout
100°C Case Operation
Short Circuit Protection
24V and 48V Inputs
Input Pi Filter and
6-Sided Shielding
Regulated Outputs
1500V Isolation
Efficiency vs. Load (24V Input)
85
80
75
EFFICIENCY %
70
65
60
55
50
LES010YE-A
EFF. (18v)
EFF. (24v)
EFF. (36v)
Technical Specifications
Input
Voltage Range
24 VDC Nominal
48 VDC Nominal
Reflected Ripple
18 - 36 VDC
36 - 75 VDC
50 mA
45
10
20
30
40
50
60
70
80
90
100
LOAD %
Output
Setpoint Accuracy
Line Regulation Vin Min. - Vin Max., Iout Rated
Load Regulation Iout Min. - Iout Max., Vin Nom.
Minimum Output Current
Dynamic Regulation, Loadstep
Pk Deviation
Settling Time
Voltage Trim Range
Short Circuit / Overcurrent Protection
Current Limit Threshold Range, % of Iout Rated
Short Circuit Current Max.
(12Vout & 15Vout : 4.0A when Vout= 0.25V)
Ovp Trip Range
Ovp Type
±1%
0.2%
Vout
0.5% Vout
10% Iout Rated
25% Iout
2% Vout
500 ms
±10%
Shutdown / Hiccup
110 - 150%
200% Iout
115 -140% Vout Nom.
Second Control Loop
85
80
75
EFFICIENCY %
Efficiency vs. Load (48V Input)
70
65
60
55
50
10
20
30
40
50
60
70
80
90
100
LOAD %
LES010ZE
LES015ZG
Notes
† MTBF predictions may vary slightly from model to model.
Specifications typically at 25°C, normal line, and full load,
unless otherwise stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully
compatible with commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model.
Please consult factory for specific model information.
Units are water-washable and fully compatible with commercial
spray or immersion post wave-solder washing equipment.
REV. JUL 11, 2003
General
Turn-On Time
Remote Shutdown
Switching Frequency
Isolation
Input - Output
Output - Case
Temperature Coefficient
Case Temperature
Operating Range
Storage Range
Humidity Max., Non-Condensing
Vibration, 3 Axes, 5 Min Each
MTBF
(Bellcore TR-NWT-000332)
Safety
10 ms
Positive/Negative Logic
400 kHz
1500 VDC
500 VDC
0.02 ppm/°C
-40 To +100°C
-40 To +100°C
95%
5 g, 10 - 55 Hz
2.5 X 106 hrs
UL, cUL, TUV
Page 1 of 3
How to use macro definitions with parameters in loop bodies?
As shown in the figure. COM is the output register of the microcontroller (I did not post the source code, but just wrote a test code, which is simple and clear). Because the register address offset c...
REMY 51mcu
I have made a real 16*16 LED display!
I now have the code and schematics, but the schematics only have the main components, such as the power supply and interface circuits. I don't know how to get them, and how to input the code into the ...
lightsite Embedded System
EEWORLD University ---- LabVIEW Tutorial Album
LabVIEW tutorial album : https://training.eeworld.com.cn/course/4362...
phantom7 Talking
How to use program control to eject the USB disk
After inserting the USB disk, I want to use evc to write a program to make the USB disk pop out, but I don’t know what function to use. If any expert knows, please help me....
zpfst Embedded System
About those electronic engineering "things" that you don't understand
[align=left] [/align][align=left] I chose hardware because I didn't want to sit in front of the screen and type code day after day. The elements in hardware circuit design work are richer, with variou...
baiheplayer Recruitment
Design Process of Junction Circulator
According to the theory of junction circulator, the general design formula is derived, the design process is proposed, and the2 cmThe band stripline circulator verifies the effectiveness of the method...
JasonYoo Test/Measurement

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 242  2141  175  301  2005  5  44  4  7  41 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号